No photo available yet
Nabertherm NA 250/85 DB200
Nabertherm NA 250/85 DB200 — Furnace Solutions 850 Degc.
The NA 250/85 DB200 is a forced-convection chamber furnace with a 250-litre chamber (600 × 750 × 600 mm) rated to 850 °C, configured for debinding. Within the NA series it is the largest chamber of the 850 °C group, distinguished by the DB200 debinding package; it serves as the thermal process stage where binder is removed from green parts before sintering.
Nabertherm NA Series — Model Comparison & Selection
| Model | Chamber volume, L | Electrical connection | Max temperature, °C |
|---|---|---|---|
| NA 250/85 DB200 Current | 250 | 3-phase | 850 |
| NA 120/65 | — | — | — |
Full specifications
| Chamber volume | 250 l |
| Electrical connection | 3-phase |
| Inner dimensions (W × D × H) mfr | 600 × 750 × 600 mm |
| Outer dimensions (W × D × H) mfr | 1115 × 1685 mm |
| Max temperature | 850 °C |
Description
Construction and series positioning
- Chamber volume 250 l; inner dimensions 600 × 750 × 600 mm (W × D × H); outer dimensions 1115 × 1685 mm (W × D).
- Maximum temperature 850 °C; 3-phase electrical connection.
- Sibling models NA 120/65, NA 250/85 and NA 60/85 share the forced-convection chamber furnace architecture; the NA 250/85 DB200 is the 250-litre, 850 °C variant with the DB200 debinding configuration. The NA 120/65 is the smaller 120-litre, 650 °C unit; the NA 60/85 is the 60-litre, 850 °C unit. Choose this model when batch volume requires the 250-litre chamber and the process requires 850 °C with debinding.
Behaviour under load and media
- No digitized curve points are available for this model; thermal behaviour must be taken from the controller documentation and factory specification sheet rather than from published curves.
- The 850 °C ceiling and forced-convection design define the working range; debinding operation relies on controlled atmosphere removal of binder, but no atmosphere or purge data is stated in the verified facts.
Installation, control and operation
- The attached controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process data storage and temperature uniformity instrumentation per AMS2750F; recorder and controller options are documented there, not in the furnace data sheet.
- No furnace-specific manual sections on connection, control or operation are present in the supplied digests; installation details must be confirmed against the model-specific instruction manual.
Integration & Operating Notes
The supplied documents do not define service intervals, error codes or consumables for this model. Maintenance planning must follow the model-specific instruction manual; do not assume intervals from the controller or catalog documents.
Selection & Integration Q&A
Pick the NA 250/85 DB200 when you need the 250-litre chamber (600 × 750 × 600 mm) and 850 °C for debinding. The NA 120/65 offers 120 l but only 650 °C; the NA 60/85 offers 850 °C but only 60 l. Choose the smaller units when batch size, not temperature, is the limiting factor.
The furnace is a 3-phase load; the controller and recorder options (500 series, MyNabertherm app) are separate devices documented in the process-control manual. The verified facts give no voltage or current, so the site supply and protection must be confirmed against the model-specific data sheet before installation.
The verified facts list no maintenance intervals, consumables or accessories. Controller and recorder options, including AMS2750F temperature-uniformity instrumentation, are documented separately and are not part of the base furnace. Service planning and spare parts must follow the model-specific instruction manual.