Nabertherm NAT 15/85
Nabertherm NAT 15/85 — Forced Convection.
The NAT 15/85 is a tabletop forced-convection chamber furnace with a 15-litre chamber (320 × 320 × 150 mm) and a maximum working temperature of 850 °C, electrically heated from a 1-phase supply. Within the NAT series it is the smallest chamber volume, distinguished from the NAT 30/65, NAT 30/85 and NAT 50/85 by its compact 15-litre workspace. It is intended for uniform low-to-medium temperature heat treatment of small batches where forced air circulation is required.
Nabertherm NAT Series — Model Comparison & Selection
Full specifications
| Chamber volume | 15 l |
| Chamber volume | 15 l |
| Chamber volume | 15 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Heating mfr | 3,0 |
| Heat-up time3 mfr | 190 |
| Inner dimensions (W × D × H) mfr | 320 × 320 × 150 mm |
| Outer dimensions (W × D × H) mfr | 690 × 880 × 570 mm |
| Weight | 85 kg |
| Weight | 85 kg |
| Weight | 85 kg |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
- Tabletop forced-convection chamber furnace, electrically heated, 1-phase connection.
- Chamber volume 15 l; inner dimensions 320 × 320 × 150 mm (W × D × H); outer dimensions 690 × 880 × 570 mm; weight 85 kg.
- Within the NAT series, the NAT 15/85 is the smallest chamber (15 l) compared with the NAT 30/65, NAT 30/85 (30 l) and NAT 50/85 (50 l). The 850 °C maximum temperature matches the NAT 30/85 and NAT 50/85; the NAT 30/65 is limited to 650 °C.
Thermal behaviour
- Maximum temperature 850 °C. Heating rating is listed as 3,0 (unit not stated in the source) and heat-up time as 190 (unit not stated). Because the units for these two values are not given in the verified facts, they are reported here only as printed and should not be used for sizing without confirmation.
- No digitized curve points are available for this model; behaviour under load cannot be quantified from the supplied data.
Control and operation
- The attached controller documentation covers the Nabertherm 500 series and MyNabertherm app, including process data storage and temperature-uniformity instrumentation per AMS2750F. No furnace-specific wiring, sensor type or controller configuration for the NAT 15/85 is stated in the supplied digests.
- The catalog section covering the NAT/NA forced-convection chamber furnaces (up to 900 °C) does not provide model-specific installation or operating instructions for the NAT 15/85.
Integration & Operating Notes
The chamber is rated to 850 °C. Operating above this limit is outside the verified specification and risks damage to the heating elements, insulation and charge. The controller setpoint and any over-temperature protection should be configured so that 850 °C cannot be exceeded in normal or fault conditions.
Selection & Integration Q&A
Choose the NAT 15/85 when the 15-litre chamber (320 × 320 × 150 mm) and 850 °C limit cover the charge and you want the smallest tabletop footprint. Move to the NAT 30/85 or NAT 50/85 when a larger batch needs the 30- or 50-litre chamber at the same 850 °C; the NAT 30/65 only if 650 °C is sufficient.
The unit is 1-phase, but the verified facts give no voltage, current or connected load in defined units. Confirm voltage, full-load current and required protection from the nameplate and order documents, then size the supply cable and breaker accordingly; do not infer them from the '3,0' heating entry.
The controller documentation covers the 500 series and MyNabertherm app with AMS2750F instrumentation options, but the supplied facts do not state which controller, thermocouple type or recorder is fitted to the NAT 15/85. These, plus any interface cables, must be specified on the order and confirmed on the order confirmation.