Nabertherm NAT 30/85
Nabertherm NAT 30/85 — Forced Convection.
The NAT 30/85 is a 30-litre forced-convection chamber furnace in Nabertherm's tabletop NAT series, electrically heated to 850 °C from a 1-phase supply. Its 320 × 320 × 300 mm chamber and 3.0 kW heating distinguish it from the 15-litre NAT 15/85 and the 650 °C NAT 30/65. It serves uniform low-to-medium temperature heat treatment in laboratory and small-batch production.
Nabertherm NAT Series — Model Comparison & Selection
Full specifications
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Chamber volume | 30 l |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Electrical connection | 1-phase |
| Heating mfr | 3,0 |
| Heat-up time3 mfr | 230 |
| Inner dimensions (W × D × H) mfr | 320 × 320 × 300 mm |
| Outer dimensions (W × D × H) mfr | 690 × 880 × 720 mm |
| Weight | 100 kg |
| Weight | 100 kg |
| Weight | 100 kg |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
| Max temperature | 850 °C |
Description
Construction and series positioning
- Tabletop forced-convection chamber furnace, electrically heated, 30 l working volume; chamber 320 × 320 × 300 mm (W × D × H), outer envelope 690 × 880 × 720 mm, 100 kg.
- Within the NAT series the 30/85 is the mid-volume 850 °C unit: the NAT 15/85 offers half the volume at the same temperature, the NAT 50/85 a larger 850 °C chamber, and the NAT 30/65 the same 30 l volume but limited to 650 °C. Choose the 30/85 when 30 l batches need the full 850 °C ceiling.
- Heating rating 3.0 kW on a 1-phase connection; heat-up time to the top of the range is quoted as 230 (minutes) in the factory data.
Thermal behaviour
- Forced convection circulates the chamber atmosphere, so load temperature uniformity depends on airflow around the charge rather than on radiant line-of-sight; the 850 °C maximum is the process limit for this modification.
- No digitized curve points were supplied for this model, so no heat-up or cooling curve is asserted here; the only thermal timing fact is the factory heat-up figure above.
Control and documentation
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and AMS2750F temperature-uniformity instrumentation types; it does not print furnace model sizes, so controller configuration must be fixed at order.
- The fiber-optics catalog section places NAT/NA forced-convection chamber furnaces in the up-to-900 °C class; the NAT 30/85 is the 850 °C member of that family.
Integration & Operating Notes
The furnace is a 1-phase unit with a 3.0 kW heating rating; the site supply, protective device and cable cross-section must be selected for that single-phase load, and the 100 kg tabletop unit needs a stable bench position within reach of the supply.
The NAT 30/85 is rated to 850 °C; the same 30-litre chamber is also built as the NAT 30/65 limited to 650 °C, so any process recipe above 650 °C must be routed to the /85 variant and must never exceed 850 °C in this unit.
Nabertherm 500-series controllers and the MyNabertherm app provide process-data storage and AMS2750F instrumentation types; because the controller documentation carries no furnace ordering codes, the required controller, recorder and uniformity class must be specified with the furnace order.
The supplied documents contain no maintenance schedule, error-code list or consumable list for the NAT 30/85; service intervals and spare parts must be taken from the furnace instruction manual supplied with the unit rather than assumed from the catalog digests.
Selection & Integration Q&A
Pick the 30/85 when 30 l batches need the full 850 °C ceiling. The NAT 15/85 gives half the volume at 850 °C, the NAT 30/65 the same 30 l but only 650 °C, and the NAT 50/85 a larger 850 °C chamber for bigger charges.
A 1-phase supply sized for the 3.0 kW heating load, plus a Nabertherm 500-series controller or MyNabertherm app configuration with the required recorder and AMS2750F instrumentation type, all fixed at order since the controller documents carry no model codes.
The digests give no service interval, error-code list or consumable schedule for the NAT 30/85, and no cables, recorder or controller are stated as included; these must be confirmed against the furnace instruction manual and the order.