Nabertherm NAT 30/85
Nabertherm ·Made in Germany · In Active Production

Nabertherm NAT 30/85

Nabertherm NAT 30/85 — Forced Convection.

The NAT 30/85 is a 30-litre forced-convection chamber furnace in Nabertherm's tabletop NAT series, electrically heated to 850 °C from a 1-phase supply. Its 320 × 320 × 300 mm chamber and 3.0 kW heating distinguish it from the 15-litre NAT 15/85 and the 650 °C NAT 30/65. It serves uniform low-to-medium temperature heat treatment in laboratory and small-batch production.

Nabertherm NAT Series — Model Comparison & Selection

Model Chamber volume, LElectrical connectionWeight, kgMax temperature, °C
NAT 30/85 Current 301-phase100850
NAT 15/85 151-phase85850
NAT 50/85 503-phase130850

Full specifications

Core Performance & Functional Specifications
Chamber volume 30 l
Chamber volume 30 l
Chamber volume 30 l
Electrical connection 1-phase
Electrical connection 1-phase
Electrical connection 1-phase
Heating mfr 3,0
Heat-up time3 mfr 230
Inner dimensions (W × D × H) mfr 320 × 320 × 300 mm
Outer dimensions (W × D × H) mfr 690 × 880 × 720 mm
Dimensions, Weight & Mechanical Design
Weight 100 kg
Weight 100 kg
Weight 100 kg
Operating Conditions, Environment & Protection
Max temperature 850 °C
Max temperature 850 °C
Max temperature 850 °C

Description

Construction and series positioning

Thermal behaviour

Control and documentation

Integration & Operating Notes

Electrical
Single-phase supply sized for the 3.0 kW heating load

The furnace is a 1-phase unit with a 3.0 kW heating rating; the site supply, protective device and cable cross-section must be selected for that single-phase load, and the 100 kg tabletop unit needs a stable bench position within reach of the supply.

Factory Specification Sheet
Process Limits
850 °C is the ceiling for this modification

The NAT 30/85 is rated to 850 °C; the same 30-litre chamber is also built as the NAT 30/65 limited to 650 °C, so any process recipe above 650 °C must be routed to the /85 variant and must never exceed 850 °C in this unit.

Factory Specification Sheet
Control & I/O
Controller and recorder options fixed at order

Nabertherm 500-series controllers and the MyNabertherm app provide process-data storage and AMS2750F instrumentation types; because the controller documentation carries no furnace ordering codes, the required controller, recorder and uniformity class must be specified with the furnace order.

Prozesssteuerung englisch
Maintenance
No model-specific service interval is published

The supplied documents contain no maintenance schedule, error-code list or consumable list for the NAT 30/85; service intervals and spare parts must be taken from the furnace instruction manual supplied with the unit rather than assumed from the catalog digests.

Fiber optics glass english 0

Selection & Integration Q&A

When should I choose the NAT 30/85 rather than the NAT 15/85, NAT 30/65 or NAT 50/85?

Pick the 30/85 when 30 l batches need the full 850 °C ceiling. The NAT 15/85 gives half the volume at 850 °C, the NAT 30/65 the same 30 l but only 650 °C, and the NAT 50/85 a larger 850 °C chamber for bigger charges.

What supply and control hardware must be provided around the NAT 30/85?

A 1-phase supply sized for the 3.0 kW heating load, plus a Nabertherm 500-series controller or MyNabertherm app configuration with the required recorder and AMS2750F instrumentation type, all fixed at order since the controller documents carry no model codes.

What maintenance and accessories are not defined by the supplied documents?

The digests give no service interval, error-code list or consumable schedule for the NAT 30/85, and no cables, recorder or controller are stated as included; these must be confirmed against the furnace instruction manual and the order.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF