Nabertherm NAT 15/85
Nabertherm ·Made in Germany · In Active Production

Nabertherm NAT 15/85

Nabertherm NAT 15/85 — Forced Convection.

The NAT 15/85 is a tabletop forced-convection chamber furnace with a 15-litre chamber (320 × 320 × 150 mm) and a maximum working temperature of 850 °C, electrically heated from a 1-phase supply. Within the NAT series it is the smallest chamber volume, distinguished from the NAT 30/65, NAT 30/85 and NAT 50/85 by its compact 15-litre workspace. It is intended for uniform low-to-medium temperature heat treatment of small batches where forced air circulation is required.

Nabertherm NAT Series — Model Comparison & Selection

Model Chamber volume, LElectrical connectionWeight, kgMax temperature, °C
NAT 15/85 Current 151-phase85850
NAT 30/85 301-phase100850
NAT 50/85 503-phase130850

Full specifications

Core Performance & Functional Specifications
Chamber volume 15 l
Chamber volume 15 l
Chamber volume 15 l
Electrical connection 1-phase
Electrical connection 1-phase
Electrical connection 1-phase
Heating mfr 3,0
Heat-up time3 mfr 190
Inner dimensions (W × D × H) mfr 320 × 320 × 150 mm
Outer dimensions (W × D × H) mfr 690 × 880 × 570 mm
Dimensions, Weight & Mechanical Design
Weight 85 kg
Weight 85 kg
Weight 85 kg
Operating Conditions, Environment & Protection
Max temperature 850 °C
Max temperature 850 °C
Max temperature 850 °C

Description

Construction and series positioning

Thermal behaviour

Control and operation

Integration & Operating Notes

Process Limits
Do not exceed the 850 °C maximum temperature

The chamber is rated to 850 °C. Operating above this limit is outside the verified specification and risks damage to the heating elements, insulation and charge. The controller setpoint and any over-temperature protection should be configured so that 850 °C cannot be exceeded in normal or fault conditions.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the NAT 15/85 rather than the NAT 30/85 or NAT 50/85?

Choose the NAT 15/85 when the 15-litre chamber (320 × 320 × 150 mm) and 850 °C limit cover the charge and you want the smallest tabletop footprint. Move to the NAT 30/85 or NAT 50/85 when a larger batch needs the 30- or 50-litre chamber at the same 850 °C; the NAT 30/65 only if 650 °C is sufficient.

What must be verified about the electrical supply before connecting the NAT 15/85?

The unit is 1-phase, but the verified facts give no voltage, current or connected load in defined units. Confirm voltage, full-load current and required protection from the nameplate and order documents, then size the supply cable and breaker accordingly; do not infer them from the '3,0' heating entry.

Which controller, sensor and recorder items are not defined in the base delivery?

The controller documentation covers the 500 series and MyNabertherm app with AMS2750F instrumentation options, but the supplied facts do not state which controller, thermocouple type or recorder is fitted to the NAT 15/85. These, plus any interface cables, must be specified on the order and confirmed on the order confirmation.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF