Nabertherm NB 650 BO
Nabertherm NB 650 BO — Thermal Cleaning Ashing.
The NB 650 BO is a 650-litre chamber furnace rated to 1000 °C, purpose-built for processes with high evaporation rates of organics and for thermal cleaning by incineration. Its 700 × 850 × 1100 mm chamber accepts up to 3500 units of organic loading, with a 135-unit output burner handling vapour burn-off. It sits above the N 300 BO in the BO series, serving as the larger-capacity incineration platform.
Nabertherm Chamber Furnaces N(B) .. BO for Processes with High Evaporation Rates of Organics or for thermal cleaning by incineratio Series — Model Comparison & Selection
| Model | Chamber volume, L | Max temperature, °C |
|---|---|---|
| NB 650 BO Current | 650 | 1000 |
| N 300 BO | 300 | 1000 |
Full specifications
| Chamber volume | 650 l |
| Output burner in mfr | 135 |
| Inner dimensions (W × D × H) mfr | 700 × 850 × 1100 mm |
| Outer dimensions (W × D × H) mfr | 1600 × 2100 × 2450 mm |
| Max. loading weight of organic substances mfr | 3500 |
| Max temperature | 1000 °C |
Description
Construction and series positioning
The NB 650 BO is the 650-litre member of Nabertherm's BO chamber furnace line, which is dedicated to processes generating high evaporation rates of organic substances and to thermal cleaning by incineration. Within the series it is the larger sibling of the N 300 BO, so the selection between them is driven by chamber volume and organic load rather than by temperature class: both share the 1000 °C maximum temperature, while the NB 650 BO offers a 700 × 850 × 1100 mm working chamber and a maximum loading weight of organic substances of 3500. The outer envelope is 1600 × 2100 × 2450 mm (W × D × H), which must be accounted for in the plant layout, including clearance for loading and for the burner exhaust path.
Behaviour under organic load
The defining process condition is the evaporation of organics, and the furnace is equipped with an output burner rated at 135 to burn off the resulting vapours. The 3500-unit maximum organic loading weight is the governing limit for batch planning: it caps how much material may be charged per cycle independently of the 650-litre geometric volume, because the burner and exhaust path must handle the vapour release rate. No digitized curve points are available for this model, so heat-up and burn-off behaviour should be taken from the process controller documentation and confirmed by trial batches rather than inferred from a published curve.
Control and documentation context
The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process data storage and temperature-uniformity instrumentation per AMS2750F, but it does not print furnace model sizes or ordering codes. The other attached digests (fiber optics glass, foundry, dental) describe different product families and do not apply to this model. Control configuration, recorder options and instrumentation type therefore need to be specified separately against the controller document at order stage.
Integration & Operating Notes
The maximum loading weight of organic substances is a process limit, not a structural one: exceeding it overloads the vapour burn-off path served by the 135 output burner, so batch weight must be checked per cycle even when the 650-litre chamber is not geometrically full.
The controller documentation covers the 500-series controllers and MyNabertherm app, including process data storage and AMS2750F instrumentation types, but prints no furnace model codes; the control package for this unit must therefore be selected explicitly and matched to the incineration process recipe.
Selection & Integration Q&A
Pick the NB 650 BO when the batch needs the 650-litre chamber (700 × 850 × 1100 mm) and organic loads up to 3500; the N 300 BO is the smaller sibling for lower-volume charges. Both share the 1000 °C maximum temperature, so the decision is capacity and organic load, not temperature class.
The unit carries a 135 output burner for burning off evaporated organics, so the exhaust path and its connection must be planned as part of the installation, and the charge weight kept within the 3500 organic loading limit so the burner sees the vapour rate it was sized for.
The controller documentation covers 500-series controllers, MyNabertherm app, process data storage and AMS2750F instrumentation options but prints no model codes, so the control and recorder package must be ordered explicitly; no cables, consumables or accessories are listed in the verified facts.