Nabertherm R 50/250/13
Nabertherm R 50/250/13 — Tube furnaces.
The R 50/250/13 is a single-phase compact tube furnace rated to 1300 °C, built around a 50 mm outer-diameter tube with a 250 mm heated length and 450 mm overall tube length. Its 80 mm constant-temperature zone and 1.9 kW connected load distinguish this short-zone modification from longer siblings such as the R 50/500/12 and larger-bore R 170/1000/13. It is intended for small-sample thermal processing where a defined uniform hot zone matters more than chamber volume.
Nabertherm Compact Tube Furnaces up to 1300 °C | Nabertherm Series — Model Comparison & Selection
| Model | Electrical connection | Max temperature, °C | Weight, kg |
|---|---|---|---|
| R 50/250/13 Current | 1-phase | 1300 | 22 |
| R 170/1000/13 | 3-phase | 1300 | 89 |
| R 50/500/12 | 1-phase | 1200 | 34 |
Full specifications
| Electrical connection | 1-phase |
| Outer tube Ø mfr | 50 |
| Heated mfr | 250 |
| Connected mfr | 1.9 |
| Outer dimensions (W × D × H) mfr | 340 × 508 mm |
| Weight | 22 kg |
| Length constant1 mfr | 80 |
| Tube length mfr | 450 |
| Max temperature | 1300 °C |
Description
Construction and series positioning
- The R 50/250/13 is the short, small-bore member of the compact tube furnace line: 50 mm outer tube diameter, 250 mm heated length, 450 mm tube length, 80 mm constant-temperature length.
- Siblings in the same series differ in bore and heated length: the R 50/500/12 keeps the 50 mm bore but doubles the heated length at a lower 1200 °C class, while the R 170/1000/13 moves to a 170 mm bore and 1000 mm heated length. Choose this model when the work fits a 50 mm tube and an 80 mm uniform zone; move to the R 50/500/12 for longer residence or larger batches at 1200 °C, and to the R 170/1000/13 for larger-diameter workloads.
- The 340 × 508 mm outer footprint and 22 kg weight make it a bench-top unit; the 1-phase connection and 1.9 kW connected load are the electrical basis for installation planning.
Thermal behavior
- Maximum working temperature is 1300 °C. The 80 mm constant-temperature length is the zone within which the 250 mm heated length is specified as uniform; workpieces or crucibles should be centered on that zone rather than spread across the full heated length.
- No digitized heating or cooling curves were supplied for this model, so no heat-up or cool-down rates are stated here. Process recipes must be established empirically or from the controller documentation.
Control and operation
- The attached controller documentation covers the Nabertherm 500-series controllers and the MyNabertherm app, including process-data storage and temperature-uniformity instrumentation per AMS2750F. It does not print model-specific wiring for the R 50/250/13, so controller configuration must be matched to the furnace at commissioning.
- The remaining attached documents (fiber-optics glass, foundry, dental) describe other product lines and contain no actionable facts for this tube furnace; they are not a basis for its installation or operation.
Integration & Operating Notes
The furnace connects to a 1-phase supply with a 1.9 kW connected load. Confirm the site circuit rating and protective device against this load before installation, and keep the supply dedicated so that controller electronics are not shared with high-inrush equipment.
The 1300 °C maximum temperature is the upper limit for the furnace and its tube assembly. Operation above this value risks tube failure and invalidates the specified thermal behavior; set the controller limit accordingly and verify with an independent thermocouple during first runs.
The uniform zone is only 80 mm long inside a 250 mm heated length. Samples or crucibles longer than this zone will see a temperature gradient; center the workload on the constant zone and account for the gradient when designing multi-step thermal profiles.
Selection & Integration Q&A
Pick the R 50/250/13 for small samples needing a defined 80 mm uniform zone at up to 1300 °C in a 50 mm tube. The R 50/500/12 gives a longer heated length but a 1200 °C class; the R 170/1000/13 is for larger-diameter, longer workloads.
It runs on a single-phase supply at 1.9 kW connected load, so size the circuit and protective device to that load. The controller is documented separately (500-series/MyNabertherm); confirm its type and any recorder option at commissioning since no model-specific wiring is printed.
The supplied documents do not list a tube, controller, thermocouple, or recorder as included, so treat the 50 mm tube and control hardware as items to specify separately. No maintenance interval is printed for this model; service planning must come from the controller and furnace documentation at handover.