Nabertherm RT 50/250/13
Nabertherm RT 50/250/13 — Tube furnaces.
The RT 50/250/13 is a horizontal/vertical tube furnace with a 50 mm inner tube diameter and a 250 mm heated length, operating up to 1300 °C on a 1-phase supply. Its 80 mm constant-temperature zone and 360 mm tube length distinguish it from the sibling RT 50/250/11, which shares the same tube geometry but a lower maximum temperature. It is intended for laboratory-scale thermal processing of small samples in controlled atmospheres or air.
Nabertherm RT Series — Model Comparison & Selection
| Model | Max temperature, °C | Electrical connection | Weight, kg |
|---|---|---|---|
| RT 50/250/13 Current | 1300 | 1-phase | 25 |
| RT 50/250/11 | 1100 | 1-phase | 25 |
Full specifications
| Electrical connection | 1-phase |
| Inner tube Ø mfr | 50 |
| Heated mfr | 250 |
| Connected mfr | 2 |
| Outer dimensions (W × D × H) mfr | 350 × 380 × 740 mm |
| Weight | 25 kg |
| Length constant mfr | 80 |
| Tube length mfr | 360 |
| Max temperature | 1300 °C |
Description
Construction and series positioning
- The RT 50/250/13 is a stand-mounted tube furnace configured for both horizontal and vertical operation, with a 50 mm inner tube diameter and a 360 mm tube length.
- The heated length is 250 mm, with an 80 mm length of constant temperature; the outer dimensions are 350 × 380 × 740 mm (W × D × H) and the unit weighs 25 kg.
- Within the series, the sibling RT 50/250/11 shares the same 50 mm tube and 250 mm heated length but has a lower maximum temperature; the RT 50/250/13 is the 1300 °C modification for work requiring the higher ceiling.
Thermal behavior and operating range
- Maximum operating temperature is 1300 °C. No digitized heating or cooling curves are available for this model, so no ramp-rate or uniformity figures are asserted here.
- The 80 mm constant-temperature length is the usable zone for samples requiring defined thermal uniformity; samples longer than this zone will see a gradient toward the tube ends.
- The 250 mm heated length and 360 mm total tube length leave overhanging tube ends for gas connections and end seals.
Electrical and control
- The furnace is connected to a 1-phase supply; the connected load is listed as 2 (unit not stated in the source data) and should be confirmed against the nameplate before sizing the circuit.
- Controller and process-data functions are not specified in the supplied digests for this model; the Nabertherm controller documentation covers the 500 series and MyNabertherm app but does not print model-specific settings for the RT 50/250/13.
Installation and operation
- The stand permits vertical or horizontal tube orientation; the chosen orientation determines how the tube is supported and how the sample is loaded.
- No manual sections specific to this model were supplied, so installation torque values, gas-panel requirements and error-code behavior cannot be stated.
Integration & Operating Notes
The heated length is 250 mm but only 80 mm is specified as constant temperature. Samples or boats longer than 80 mm will straddle the gradient zone toward the tube ends, so position the workload centrally and verify uniformity with a test run before committing to a process.
The furnace is supplied with a stand for horizontal and vertical operation. The chosen orientation changes how the tube is supported and how the sample is introduced; plan bench height, tube overhang (360 mm tube in a 250 mm heated length) and access for loading before installation.
The Nabertherm controller digest covers the 500 series and MyNabertherm app in general terms but does not specify which controller is fitted to the RT 50/250/13. Confirm the controller model, interface options and any process-data recording requirements with the order documentation before integrating with a supervisory system.
Selection & Integration Q&A
Choose the /13 when the process needs temperatures up to 1300 °C; the /11 shares the 50 mm tube and 250 mm heated length but has a lower maximum temperature. If your peak temperature stays below the /11 limit, the /11 avoids paying for a higher-temperature element set.
It is a 1-phase unit; the connected load is listed as '2' without a unit in the source data, so read the nameplate for the actual kW/A and size breaker and cable to that value. Do not infer the load from the series or from the sibling model.
Yes — the stand is designed for horizontal and vertical operation. Vertical mounting changes sample retention and tube support; with a 360 mm tube in a 250 mm heated length, plan the overhang and end fittings for the chosen orientation before installation.
The supplied documents do not define a maintenance schedule or a consumables list for this model. Plan for replacement tubes and end seals as wear items and confirm controller options and any gas-panel accessories with the order documentation; none are confirmed as included in base delivery.