No photo available yet

Nabertherm ·Made in Germany · In Active Production

Nabertherm SAL 250/85

Nabertherm SAL 250/85 — Forced Convection Furnaces.

The SAL 250/85 is a forced-convection pit-type furnace with a 250-litre chamber (600 × 600 × 750 mm) and a maximum working temperature of 850 °C. It is the larger of the two SAL 85-series models, distinguished from the SAL 120/85 by its 250-litre volume and 250 kg maximum charge weight. It is intended for uniform heat treatment of dense loads in a floor-level configuration.

Nabertherm SAL Series — Model Comparison & Selection

Model Chamber volume, LWeight, kgElectrical connectionMax temperature, °C
SAL 250/85 Current 2506003-phase850
SAL 120/85 1204003-phase850

Full specifications

Core Performance & Functional Specifications
Chamber volume 250 l
Chamber volume 250 l
Electrical connection 3-phase
Electrical connection 3-phase
Heating mfr 20
Inner dimensions (W × D × H) mfr 600 × 600 × 750 mm
Outer dimensions (W × D × H) mfr 1500 × 1300 × 1600 mm
Dimensions, Weight & Mechanical Design
Weight 600 kg
Weight 600 kg
Electrical, Power & Drive Specifications
Max. charging weight mfr 250
Operating Conditions, Environment & Protection
Max temperature 850 °C
Max temperature 850 °C

Description

Construction and series positioning

Working range and load behaviour

Installation and control

Integration & Operating Notes

Process Limits
Charge weight must not exceed 250 kg regardless of volume

The maximum charging weight is 250 kg. A load that fits within the 600 × 600 × 750 mm chamber can still exceed this limit if it is dense; the charge must be weighed or calculated, not judged by chamber fill alone.

Factory Specification Sheet
Process Limits
850 °C maximum temperature is a hard process ceiling

The maximum temperature of 850 °C applies to the furnace; processes requiring higher temperatures must use a different furnace category. Exceeding it risks damage to the heating elements and chamber insulation.

Factory Specification Sheet
Control & I/O
Controller options documented separately from furnace data

Process control functions, data storage and recorder options are described in the Nabertherm controller documentation (series 500 and MyNabertherm app). The controller configuration for this specific unit is not fixed in the verified facts and must be confirmed at order.

Prozesssteuerung englisch

Selection & Integration Q&A

When should I choose the SAL 250/85 rather than the SAL 120/85?

Choose the SAL 250/85 when the charge requires the 250-litre chamber (600 × 600 × 750 mm) or approaches the 250 kg charging weight. The SAL 120/85 has a 120-litre chamber; both share the 850 °C maximum temperature, so the decision is volume and load weight, not temperature.

What electrical supply and protective devices does the SAL 250/85 require?

The furnace is a 3-phase unit. The verified facts do not state the connected load in kW or the full-load current, so the feeder, breaker and cable sizing must be based on the nameplate data supplied with the unit, not on generic assumptions.

What is included in base delivery and what must be ordered separately?

The verified facts list only the furnace itself; controller type, recorder options and process-data software are described in separate Nabertherm controller documentation and are not confirmed as part of the base delivery. Confirm controller, thermocouples and any recorder as order options.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Prozesssteuerung englisch
Brochure ·2,8 МБ ·20 pp.
View PDF
PDF
Fiber optics glass english 0
Brochure ·10,3 МБ ·97 pp.
View PDF
PDF
Foundry english
Brochure ·4,2 МБ ·52 pp.
View PDF
PDF
Dental english
Brochure ·13,1 МБ ·72 pp.
View PDF