Shimadzu I Series

Shimadzu I Series — Chromatographs.

The Shimadzu LC-2070 series comprises integrated HPLC systems with a four-solvent low-pressure gradient pump, total-volume injection autosampler, and UV or PDA detection. This model (LC-2070) is the base UV configuration without sample cooler, distinguished from the LC-2070C (cooled) and LC-2070C 3D (PDA) siblings. It serves as a compact, high-pressure (up to 50 MPa) analytical platform for routine gradient separations.

Direct drop-in replacements

71%
match
⚖️ Compare
⚖️ Compare
50%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Detector types UV (LC-2070)
Maximum pressure (3.0001 to 5 mL/min) mfr 44 MPa (3.0001 to 5 mL/min)
Detector (LC-2070C) mfr UV (LC-2070C)
Detector (LC-2070C 3D) mfr PDA (LC-2070C 3D)
Detector (LC-2080C) mfr UV (LC-2080C)
Detector (LC-2080C 3D) mfr PDA (LC-2080C 3D)
Column capacity (column oven) mfr up to six 100 mm columns (column oven)
Maximum pressure (LC-2070C / LC-2080C, 3.0001 to 5 mL/min) mfr 44 MPa (LC-2070C / LC-2080C, 3.0001 to 5 mL/min)
System delay volume (LC-2070C) mfr 650 μL (LC-2070C)
System delay volume (LC-2080C) mfr 460 μL (LC-2080C)
System delay volume option (LC-2070C) mfr 460, 1100 μL (LC-2070C)
System delay volume option (LC-2080C) mfr 650, 1100 μL (LC-2080C)
Flow cell volume (Conventional cell, 10 mm, TC) mfr 12 μL (Conventional cell, 10 mm, TC)
Flow cell volume (High-Speed cell, 10 mm, TC) mfr 8 μL (High-Speed cell, 10 mm, TC)
Flow cell pressure rating (Flow cell) mfr 12 MPa (Flow cell)
Detector wavelength range (UV detector) mfr 200 to 650 nm (UV detector)
Detector wavelength range (PDA detector) mfr 200 to 750 nm (PDA detector)
Detector dimensions (W × D × H) (UV detector) mfr 260 × 420 × 210 mm (UV detector)
Injection cycle time (Autosampler) mfr 14 s (Autosampler)
Maximum sample capacity (Autosampler, using 384-well MTPs) mfr 1536 samples (Autosampler, using 384-well MTPs)
Carryover (Autosampler) mfr < 0.0004 % (Autosampler)
Minimum injection volume (Autosampler, reproducible/linear) mfr 1 μL (Autosampler, reproducible/linear)
Dimensions, Weight & Mechanical Design
Weight 58 kg (LC-2070)
Weight (LC-2070C / LC-2070C 3D) mfr 63 kg (LC-2070C / LC-2070C 3D)
Weight (LC-2080C / LC-2080C 3D) mfr 63 kg (LC-2080C / LC-2080C 3D)
Detector weight (UV detector) mfr 16 kg (UV detector)
Detector weight (PDA detector) mfr 18 kg (PDA detector)

Description

Construction and Series Positioning

The LC-2070 is a fully integrated HPLC system combining a quaternary low-pressure gradient pump, autosampler, and UV detector in a single 58 kg chassis. Within the series, it is the entry UV variant: the LC-2070C adds a sample cooler (4–45 °C), and the LC-2070C 3D replaces the UV detector with a photodiode array (PDA). All share the same pump, autosampler, and pressure specifications. The pump features a five-line degassing unit (four mobile phases + one rinse solution, 400 µL) and supports gradient formation from 0 to 100% in 0.1% steps. ### Hydraulic and Injection Behavior

Maximum operating pressure is flow-dependent: 50 MPa up to 3 mL/min, 44 MPa from 3.0001 to 5 mL/min, and 22 MPa from 5.0001 to 10 mL/min. The system delay volume is 650 µL standard, with 460 µL and 1100 µL options. The autosampler uses total-volume injection, with injection volumes from 0.1 to 100 µL standard (options up to 2000 µL). Injection accuracy is ±1% at 50 µL (N=10), and reproducibility ranges from RSD <0.20% for 5–2000 µL down to RSD <1.0% for 0.5–0.9 µL. The available pH range is 1 to 13, compatible with standard reversed-phase methods. The system is designed for benchtop use and requires connection to laboratory power and data systems per Shimadzu's standard instructions. The absence of a sample cooler means samples are processed at ambient temperature, which may affect thermally labile analytes compared to the LC-2070C.

Integration & Operating Notes

Process Limits
Pressure limit drops with flow rate above 3 mL/min

Exceeding 50 MPa at flows up to 3 mL/min, 44 MPa between 3.0001 and 5 mL/min, or 22 MPa above 5 mL/min risks column or system damage. Method development must account for the flow-dependent pressure ceiling, especially when scaling up flow rate or using small-particle columns.

Factory Specification Sheet
Process Limits
pH must stay within 1–13 for wetted parts

Mobile phases outside pH 1–13 can degrade the pump, injector, and detector flow cell. Buffers and additives must be chosen accordingly, and post-run flushing is recommended to remove aggressive salts.

Factory Specification Sheet
Maintenance
Rinse solution line requires periodic replenishment

The degassing unit includes a dedicated rinse solution line (400 µL volume) to flush the autosampler. This reservoir must be kept filled with appropriate solvent (e.g., water or methanol) to prevent precipitate buildup and injection carryover; check level before each batch.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the LC-2070 instead of the LC-2070C or LC-2070C 3D?

Choose the LC-2070 for ambient-temperature UV detection when sample cooling is unnecessary and PDA spectral data is not required. The LC-2070C adds a 4–45 °C sample cooler for thermally labile analytes; the LC-2070C 3D provides PDA detection for peak purity and multi-wavelength analysis.

What maintenance items and accessories are not included in the base delivery?

The base LC-2070 includes the pump, autosampler, UV detector, and standard 100 µL injection kit. Optional injection volumes (up to 2000 µL), delay volume kits (460 µL or 1100 µL), and the sample cooler are not included. Routine maintenance parts such as column, filters, and tubing are user-supplied.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
c196-e100
Datasheet ·4,0 МБ ·16 pp.
View PDF
PDF
c196-e101
Datasheet ·1,4 МБ ·8 pp.
View PDF