Shimadzu Nexera UC Prep
Shimadzu Nexera UC Prep — Chromatographs.
The Shimadzu Nexera UC Prep is a preparative supercritical fluid chromatography (SFC) system configured for purification-scale separations. It extends the analytical Nexera UC platform to milligram-to-gram throughput by integrating a preparative pump, injection valve, and fraction collector. Its primary purpose is isolating target compounds from complex matrices with CO2-based mobile phases, reducing organic solvent consumption versus conventional preparative HPLC.
Direct drop-in replacements
Full specifications
| Maximum operating pressure (UHPLC/SFC switching system) mfr | 66 MPa (UHPLC/SFC switching system) |
| Number of switchable columns (chiral screening system) mfr | up to 12 columns (chiral screening system) |
| Number of switchable modifiers (chiral screening system) mfr | 7 types (chiral screening system) |
| Fractionation scale (2.0 mm I.D. column) mfr | 5 mg (2.0 mm I.D. column) |
| Fractionation scale (4.6 mm I.D. column) mfr | 100 mg (4.6 mm I.D. column) |
| Fractionation scale (10 mm I.D. column) mfr | 500 mg (10 mm I.D. column) |
| Fractionation scale (20 mm I.D. column) mfr | 1 g (20 mm I.D. column) |
| Flow rate (4.6 mm I.D. column, Shim-pack UC-PBr 4.6 x 250 mm) mfr | 3.0 mL/min (4.6 mm I.D. column, Shim-pack UC-PBr 4.6 x 250 mm) |
| Flow rate (20 mm I.D. column, Shim-pack UC-PBr 20 x 250 mm) mfr | 56.7 mL/min (20 mm I.D. column, Shim-pack UC-PBr 20 x 250 mm) |
| Injection volume (4.6 mm I.D. column) mfr | 20 μL (4.6 mm I.D. column) |
| Injection volume (20 mm I.D. column) mfr | 500 μL (20 mm I.D. column) |
| Fraction volume (4.6 mm I.D. column) mfr | 10 mg (4.6 mm I.D. column) |
| Fraction volume (20 mm I.D. column) mfr | 250 mg (20 mm I.D. column) |
| Typical sample preparation time (on-line SFE-SFC) mfr | 60 minutes (on-line SFE-SFC) |
| System (Recovery rate test) mfr | Nexera UC Prep Stacked fraction system (Recovery rate test) |
| Flow rate (Recovery rate test) mfr | 125 mL/min (Recovery rate test) |
| Detection wavelength (Caffeine, recovery rate test) mfr | 272 nm (Caffeine, recovery rate test) |
| BPR pressure (Recovery rate test) mfr | 10 MPa (Recovery rate test) |
| Sample concentration (Caffeine, recovery rate test) mfr | 10 mg/mL (Caffeine, recovery rate test) |
| Injection volume (Recovery rate test) mfr | 1 mL (Recovery rate test) |
| Modifier (LotusStream separator test) mfr | Methanol (LotusStream separator test) |
| Modifier concentration (LotusStream separator test) mfr | 20 % (LotusStream separator test) |
| Modifier flow rate (LotusStream separator test) mfr | 100 mL/min (LotusStream separator test) |
| System (Contamination test) mfr | Nexera UC Prep Multi-fraction system (Contamination test) |
| Makeup (Contamination test) mfr | Methanol (Contamination test) |
| Makeup flow rate (Contamination test) mfr | 15 mL/min (Contamination test) |
| BPR pressure (Contamination test) mfr | 10 MPa (Contamination test) |
| Sample (Contamination test) mfr | Linalool 1 % (Contamination test) |
| Fraction collector (Contamination test) mfr | FRC-40 SF (Contamination test) |
| Column (Carryover test) mfr | Silica column (250 mm L. × 20 mm I.D.) (Carryover test) |
| Makeup flow rate (Carryover test) mfr | 10 mL/min (Carryover test) |
| Sample concentration (Hydrocortisone, carryover test) mfr | 30 mg/mL (Hydrocortisone, carryover test) |
| Modifier (Carryover test) mfr | Methanol (Carryover test) |
| Flow rate (Carryover test) mfr | 3 mL/min (Carryover test) |
| Allowable maximum pressure (LC-40D) mfr | 44 MPa (LC-40D) |
| Allowable maximum pressure (LC-40D XR) mfr | 70 MPa (LC-40D XR) |
| Allowable maximum pressure (LC-40D XS) mfr | 105 MPa (LC-40D XS) |
| Allowable maximum pressure (LC-40D X3) mfr | 130 MPa (LC-40D X3) |
| Flow rate settings range (LC-40D, 1.0 to 44 MPa) mfr | 0.0001 to 5.0000 mL/min (LC-40D, 1.0 to 44 MPa) |
| Flow rate settings range (LC-40D, 1.0 to 22 MPa) mfr | 5.0001 to 10.0000 mL/min (LC-40D, 1.0 to 22 MPa) |
| Flow rate accuracy (under specified conditions) mfr | ≤ ± 1% or ± 2 μL/min, whichever greater (under specified conditions) |
| Flow rate precision mfr | ≤ 0.06% RSD or 0.02 minSD, whichever greater |
| Gradient range of set concentrations (0.1% step) mfr | 0 to 100 % (0.1% step) |
| Gradient concentration accuracy (under specified conditions) mfr | ± 0.5 % (under specified conditions) |
| Dimensions (LC-40D) mfr | W 260 × D 500 × H 140 mm (LC-40D) |
| Plunger capacity (LC-20AR) mfr | 47 μL (LC-20AR) |
| Flow rate setting range (LC-20AR, 1.0 to 50 MPa) mfr | 0.001 to 5 mL/min (LC-20AR, 1.0 to 50 MPa) |
| Flow rate setting range (LC-20AR, 1.0 to 25 MPa) mfr | 5.001 to 20 mL/min (LC-20AR, 1.0 to 25 MPa) |
| Flow rate accuracy (LC-20AR, 0.1 to 5.0 mL/min) mfr | No more than ±1% or ±10 μL/min, whichever is gre (LC-20AR, 0.1 to 5.0 mL/min) |
| Flow rate precision (LC-20AR) mfr | No more than 0.08% RSD or 0.02 min SD, whichever (LC-20AR) |
| Number of degassed solvents (DGU-403) mfr | 3 (DGU-403) |
| Degassed flow line capacity (DGU-403) mfr | 400 μL/1 line (DGU-403) |
| Injection volume accuracy (SIL-40C XR, 5 μL injection, n = 20) mfr | ≤ ± 1 % (SIL-40C XR, 5 μL injection, n = 20) |
| Wavelength range (SPD-40) mfr | 190 to 700 nm (SPD-40) |
| Column inner diameter mfr | 4.6 mm I.D. (Nexera UC) |
| Column inner diameter mfr | 30 mm I.D. (Nexera UC Prep) |
| Weight (LC-40D) mfr | 10 kg (LC-40D) |
| Weight (LC-40D XR) mfr | 12 kg (LC-40D XR) |
| Power supply (LC-40D series) mfr | 100 to 240 V AC, 150 VA, 50/60 Hz (LC-40D series) |
| Available pH range mfr | 1 to 14 |
Description
Construction and Series Positioning
The Nexera UC Prep is the preparative-scale member of Shimadzu's Nexera UC supercritical fluid chromatography family. While analytical Nexera UC systems prioritize resolution and detection sensitivity at microliter flow rates, the UC Prep modification substitutes a higher-capacity pumping module, a larger-volume injection loop, and a fraction collection stage to handle elevated mass loads. The architecture retains the CO2 delivery and back-pressure regulation scheme common to the series but scales column dimensions and flow-path components accordingly. ### Behavior Under Load and Across Media
Supercritical CO2 serves as the primary mobile phase, with an organic co-solvent (typically methanol or ethanol) added via a secondary pump to modulate polarity. Because the mobile phase is compressible, system pressure must be actively regulated at the back-pressure regulator to maintain a stable supercritical state throughout the column and into the detector. At preparative scale, the ratio of co-solvent to CO2 and the total flow rate determine both retention and the recovery window for fraction collection; these parameters are method-specific and must be established empirically for each target-compound/matrix pair. ### Installation, Connection, and Control
Installation requires a CO2 supply with adequate pressure and purity, an exhaust/vent path for depressurized gas, and a solvent reservoir for the co-solvent pump. The system is controlled through Shimadzu's chromatography data system, which coordinates injection, gradient delivery, back-pressure regulation, and fraction-valve switching. Fraction collection timing is triggered by time-based or signal-threshold events programmed in the method; the collector must be configured with the appropriate tube or plate format before a run.
Integration & Operating Notes
The back-pressure regulator and pump seals are wear items exposed to pressurized CO2 and co-solvent. The manual specifies periodic inspection and replacement intervals; neglecting these can lead to pressure drift, seal leakage, and inconsistent retention times. Keep spare seal kits and regulator components on hand, and log pressure stability as an early indicator of wear.
The system requires a stable laboratory bench with sufficient clearance for the preparative pump, column oven, detector, and fraction collector, plus a vent path for depressurized CO2. Because CO2 is heavier than air, the installation area should be ventilated at low level to prevent accumulation; confirm room ventilation meets the manual's requirements before commissioning.
Selection & Integration Q&A
Choose the UC Prep when the goal is isolating milligram-to-gram quantities of target compounds and fraction collection is required. Analytical Nexera UC systems are optimized for resolution and detection at microliter flow rates and lack preparative-scale pumping and collection hardware.
The system needs instrument-grade, moisture-free CO2 at sufficient inlet pressure to stay above the critical point, plus a co-solvent pump fed from a compatible solvent reservoir. Verify supply pressure and purity against the manual's installation requirements before commissioning.
Base delivery typically excludes consumable pump seals, back-pressure regulator rebuild kits, fraction collection tubes or plates, and the CO2 supply regulator and plumbing. These must be ordered separately; consult the manual's maintenance schedule for replacement intervals.