Shimadzu TOC 4200
Shimadzu TOC 4200 — Gas analyzers.
The Shimadzu TOC 4200 is a wall-mounted online total organic carbon analyzer using 680°C combustion catalytic oxidation with NDIR detection. It measures TC and NPOC (optional IC, POC, TOC, TN) over a range of 0–5 to 0–1,000 mgC/L full scale, extendable to 20,000 mgC/L with internal dilution. Designed for continuous monitoring in industrial and environmental water systems, it provides analog and contact outputs for integration with plant control.
Full specifications
| Measurement range | 0 - 5 to 0 - 1,000 mgC/L f.s. (0 to 20,000 mgC/L f.s. with dilution function) From |
| High-sensitivity measurement range (TOC-4200, optional) mfr | 0 to 1 mgC/L (TOC-4200, optional) |
| Number of flow lines (multi-stream sample switching unit) mfr | up to six flow lines (multi-stream sample switching unit) |
| Measuring cycle (short measuring cycle) mfr | 4 minutes (short measuring cycle) |
| Maintenance space (external dimensions) mfr | over 500 mm (external dimensions) |
| Data storage function mfr | 20,000 past |
| Dimensions mfr | 550 x |
| Construction mfr | Indoor wall mounting (optional stand available) |
| Carrier gas mfr | 4 |
| Communication function mfr | -485 RS |
| Contact input mfr | 1 to 6 halt |
| Analog output mfr | 4 |
| Printer mfr | 40 characters |
| Recorder mfr | 100 mm |
| Data storage device mfr | 3 |
| EPA TOC removal rate calculation function mfr | 40 CFR |
| Measurement principle mfr | 680 |
| Load calculation function mfr | 100 ohms |
| Conversion function mfr | Conversion with a linear expression using requir |
| Stream switching function mfr | 1 to 6 can |
| Automatic calibration function mfr | 5 |
| Sample dilution function mfr | 2 to 50 Dilution |
| IC removal method mfr | Acidify/sparge within syringe |
| Sample injection method mfr | Syringe pump/sliding injection port |
| Measurement cycle mfr | 4 minutes |
| Zero stability mfr | 2 % |
| Span stability mfr | 2 % |
| Repeatability mfr | 2 % |
| Width (external dimensions) mfr | 550 mm (external dimensions) |
| Depth (external dimensions) mfr | 388 mm (external dimensions) |
| Height (external dimensions) mfr | 214 mm (external dimensions) |
| Weight mfr | 70 kg |
| Power supply mfr | 100 to 240 V |
| Contact output signal mfr | 2 A |
| Display, operation mfr | Color LCD with touch screen |
| Dilution factor (TOC-4200, standard dilution function) mfr | up to 50x (TOC-4200, standard dilution function) |
Description
Construction and positioning
- The TOC 4200 is an indoor, wall-mounted unit (optional stand available) with a color LCD touch screen for local operation. It is the base model in the series, distinguished by its standard measurement items (TC, NPOC) and optional extensions (IC, POC, TOC, TN). - Sample introduction uses a syringe pump and sliding injection port, with in-syringe dilution (factor 2–50) and acidify/sparge for IC removal. The combustion furnace operates at 680°C with NDIR detection. ### Measurement behavior
- The analyzer provides a measurement range from 0–5 to 0–1,000 mgC/L full scale, and with the dilution function up to 20,000 mgC/L full scale. Repeatability is within ±2% f.s., and zero/span stability is within ±2% f.s. per day (temperature variation within 5°C). - The minimum measurement cycle is 4 minutes for NPOC with residual IC ≤2%. Automatic calibration is supported using standard solutions, with options for up to eight standards. The system stores 20,000 on-line measured values (about one year at 30-minute intervals) and offers trend graphs. ### Installation and operation
- The unit requires AC 100–240 V ±10%, 10 A, 50/60 Hz power. Carrier gas can be pressurized air, high-purity air, or oxygen at 250–300 kPa supply pressure; high-purity nitrogen is optional. - Communication interfaces include RS-485, RS-232C (option), and Modbus. Contact inputs allow start/stop of calibration and measurement, alarm reset, and flow line selection (1–6). Contact outputs provide alarm and event signals. Analog outputs are selectable 4–20 mA or 0–16 mA DC (isolated), with up to 12 outputs when the option is attached. A USB port allows data storage to USB memory (FAT16/FAT32, no encryption). - The EPA TOC removal rate calculation function is available when a 2- or more-stream switching option is provided. Load calculation is possible with the optional analog input board.
Integration & Operating Notes
The analyzer draws up to 10 A at 100–240 V AC ±10%, 50/60 Hz. Ensure the circuit and wiring are rated for this current and that a suitable disconnect device is provided. Voltage fluctuations beyond ±10% may affect performance.
Use pressurized air, high-purity air, or oxygen (or optional high-purity nitrogen) with a supply pressure of 250–300 kPa. Pressure outside this range can cause incomplete combustion or detector noise, invalidating measurements.
Selection & Integration Q&A
Choose the TOC 4200 if you need standard TC and NPOC monitoring with the option to add IC, POC, TOC, or TN later. If you require simultaneous TN or IC measurement out of the box, consider a higher-tier model in the series that includes those as standard.
The analyzer offers RS-485, RS-232C (option), and Modbus communication. For analog signals, select 4–20 mA or 0–16 mA DC isolated outputs (load ≤500 Ω). Contact inputs need dry contacts rated ≥1.4 V DC, 10 mA. Ensure proper grounding and cable shielding.
The base delivery includes the analyzer but not the optional stand, printer, recorder, or USB memory. Calibration standards, carrier gas regulators, and consumables like combustion tubes and catalysts are not included. Regular maintenance kits are available separately.