Waters ACQUITY QDa II - Single Quadrupole Mass Spec Detector
Waters ACQUITY QDa II - Single Quadrupole Mass Spec Detector — Mass spectrometers.
The ACQUITY QDa II is a single quadrupole mass detector with a mass range of m/z 30–1250 and positive/negative electrospray ionization. It integrates with ACQUITY UPLC, ACQUITY Arc, and Alliance HPLC systems, providing mass confirmation for chromatographic peaks. Its compact design and ESI source make it suitable for routine LC-MS analyses in pharmaceutical and chemical laboratories.
Direct drop-in replacements
Full specifications
| Type | single quadrupole |
| Ion source | positive and negative electrospray ionization |
| Compatible chromatography systems mfr | ACQUITY UPLC, ACQUITY Arc, Alliance HPLC |
| Mass range | m/z 30 to 1250 |
Description
Construction and positioning
- Single quadrupole mass analyzer with electrospray ionization (ESI) source, operable in positive and negative modes. - Designed as a detector for Waters ACQUITY UPLC, ACQUITY Arc, and Alliance HPLC systems, not as a standalone instrument. ### Behavior under load
- Mass range covers m/z 30 to 1250, suitable for small molecules and some larger compounds. - ESI source supports both positive and negative ionization, allowing analysis of a wide range of analytes. - No curve points or detailed performance data (e.g., scan speed, resolution) are provided; refer to the instrument manual for acquisition parameter optimization. ### Installation and operation
- The system requires connection to a compatible chromatography system and appropriate electrical supply (voltage not specified in facts). - Control and data acquisition are typically managed via Waters MassLynx software (not explicitly stated in facts; confirm with manual).
Integration & Operating Notes
The QDa II is a benchtop detector that must be placed close to the LC system to minimize tubing length. Ensure adequate ventilation and access for maintenance. No specific mounting hardware is mentioned in the facts.
The electrospray ionization source typically requires volatile buffers and solvents to prevent contamination and maintain sensitivity. Avoid non-volatile salts and strong acids unless using appropriate ionization techniques. Refer to the manual for specific solvent compatibility.
Selection & Integration Q&A
The QDa II is specifically designed for integration with Waters ACQUITY UPLC, ACQUITY Arc, and Alliance HPLC systems, offering seamless control and data acquisition. Choose it when you need a compact, ESI-based single quadrupole for routine mass confirmation within a Waters chromatography workflow. For other LC brands or higher resolution requirements, consider alternative detectors.
The QDa II is compatible with ACQUITY UPLC, ACQUITY Arc, and Alliance HPLC systems. Connection typically involves plumbing the LC effluent to the ESI source and configuring the system software (e.g., MassLynx) for communication. Ensure the LC system is equipped with a suitable interface and that the QDa II is placed close to minimize dead volume.
Regular maintenance includes cleaning the ESI source and replacing the ESI probe as needed. Consumables such as ESI emitters and solvent filters are not included in the base delivery and must be ordered separately. Refer to the manual for the specific maintenance schedule and part numbers.