Waters BioAccord LC-MS System
Waters ·Made in USA · In Active Production

Waters BioAccord LC-MS System

Waters BioAccord LC-MS System — Mass spectrometers.

The BioAccord LC-MS System is an integrated liquid chromatography–mass spectrometry platform combining a binary solvent manager, sample manager, column manager, and a quadrupole time-of-flight mass spectrometer. It delivers intact mass accuracy within 20 ppm and peptide mapping sequence coverage over 87%, with deconvoluted intensity reproducibility below 5% RSD. Designed for biopharmaceutical characterization, it supports intact mass analysis and peptide mapping across a 25–2,500 ng concentration range.

Direct drop-in replacements

Shimadzu
Axima Assurance
0%
match
⚖️ Compare
Shimadzu
Axima Confidence
0%
match
⚖️ Compare
0%
match
⚖️ Compare
Shimadzu
GC-MS Qp2020 NX
0%
match
⚖️ Compare

Full specifications

Core Performance & Functional Specifications
Deconvoluted intensity reproducibility mfr <5% RSD
Concentration range mfr 25 ng to 2,500 ng
Sequence coverage (peptide mapping) mfr over 87%
Dimensions, Weight & Mechanical Design
Mass accuracy (intact mass) mfr within 20 ppm
Mass precision mfr <5 ppm
Precursor mass accuracy (peptide mapping) mfr <10 ppm

Description

System Architecture and Positioning

The BioAccord LC-MS System is a fully integrated LC-MS platform that bundles a binary solvent manager, sample manager, column manager, and a QToF mass spectrometer into a single controlled system. Unlike modular LC-MS configurations that require user assembly and tuning, this system is factory-integrated and calibrated for biopharmaceutical workflows. ### Performance Under Analytical Conditions

Integration & Operating Notes

Process Limits
Sample concentration must stay within 25–2,500 ng

Operating outside this range may compromise mass accuracy and reproducibility; samples outside the range should be diluted or concentrated and re-analyzed to ensure valid results.

Factory Specification Sheet
Maintenance
Regular calibration and performance verification required

To maintain mass accuracy within 20 ppm and reproducibility below 5% RSD, schedule routine calibration and system suitability checks as per the manufacturer’s recommendations; failure to do so may invalidate results.

Factory Specification Sheet
Electrical
Verify site power and gas supplies before installation

The system requires stable electrical power and high-purity nitrogen for the mass spectrometer; consult the site preparation guide for exact voltage, current, and gas specifications to avoid installation delays.

Instruction Manual, Site Preparation

Selection & Integration Q&A

When should I choose the BioAccord LC-MS System instead of a modular LC-MS setup?

Choose BioAccord for an integrated, factory-calibrated system that simplifies biopharmaceutical intact mass and peptide mapping workflows. Modular systems offer flexibility but require user assembly and tuning, which can introduce variability.

What are the requirements for connecting the BioAccord to my existing LC system?

The BioAccord is a fully integrated LC-MS system that includes its own LC components; it is not designed to connect to an external LC. Ensure your laboratory has appropriate electrical, gas, and solvent supplies as specified in the site preparation guide.

What maintenance and consumables are required, and what is not included in the base delivery?

The base system includes the instrument and software, but consumables such as columns, solvents, and calibration standards are not included. Regular maintenance includes cleaning the ion source and replacing filters; refer to the maintenance schedule in the manual.