Waters RADIAN ASAP Single Quadrupole Direct Mass Detector
Waters RADIAN ASAP Single Quadrupole Direct Mass Detector — Mass spectrometers.
The RADIAN ASAP is a single quadrupole mass detector configured with an Atmospheric Solids Analysis Probe (ASAP) for direct analysis of solids and liquids without chromatographic separation. It delivers nominal-mass confirmation in approximately 30 seconds per sample, distinguishing it from LC-MS or GC-MS variants that require separation time. It is used for rapid screening and identity checks in laboratories where speed and simplicity outweigh high-resolution accuracy.
Direct drop-in replacements
Full specifications
| Type | single quadrupole |
| Ion source | Atmospheric Solids Analysis Probe (ASAP) |
| analysis time mfr | approximately 30 seconds per sample |
Description
Construction and positioning
- Single quadrupole mass analyzer with an ASAP ion source; no front-end chromatography is required. - The ASAP probe enables direct introduction of solid or liquid samples into the ion source, bypassing LC or GC separation. - This model is a dedicated direct-analysis configuration; it is not a general-purpose LC-MS detector and cannot be converted to chromatographic operation without additional hardware. ### Behavior under load
- Analysis time is approximately 30 seconds per sample, from probe insertion to result. - The single quadrupole provides nominal-mass spectra suitable for targeted screening and confirmation of known analytes. ### Installation and operation
- No installation, connection, or control details are available from the supplied documentation; refer to the manufacturer's site preparation guide for electrical, vacuum, and gas requirements. - The ASAP probe is a consumable accessory; spare probes and sample capillaries should be stocked for continuous operation.
Integration & Operating Notes
Samples must be applied directly to the ASAP probe capillary and dried before insertion; liquid samples may need a solvent that evaporates completely to avoid source contamination. The probe operates at atmospheric pressure and is inserted into the source only after the sample is ready.
The disposable capillary at the tip of the ASAP probe is a consumable; it should be replaced when carryover is observed or after analyzing samples with high analyte concentration. Keep spare capillaries and probe assemblies on hand to avoid downtime.
Selection & Integration Q&A
Choose the ASAP when you need rapid, direct analysis of solids or liquids without separation, such as raw material identification or reaction monitoring. For complex mixtures requiring chromatographic separation, an LC-MS or GC-MS configuration is necessary.
The probe capillary should be replaced when carryover is detected or after high-concentration samples. The probe body can be cleaned with appropriate solvents. Regular replacement of the capillary ensures reproducible results.
The MassLynx software, ASAP probe capillaries, and a nitrogen generator or gas cylinder are typically not included and must be ordered separately. A computer meeting the software specifications is also required.