Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN)
Technical Reference Summary
Covered Models & Document Scope
Data sheet 2BH7 630-0A: side channel blower with integrated frequency converter (VFD), G-BH7 e series. Covers 2BH7630-0A variants with 100 Hz/400 V, 85 Hz/380 V, and 85 Hz/400 V delta motors, plus VFD types A–K (2FC4xxx-1) and accessories.
Technical Data
| Parameter | Value | Condition |
|---|---|---|
| Rated frequency | 100 Hz p.2 ↗ | 2BH7630-0A361-2 |
| Rated voltage | 400 V p.2 ↗ | 2BH7630-0A361-2 |
| Rated current | 29,0 A p.2 ↗ | 2BH7630-0A361-2 |
| Rated motor power | 16,0 kW p.2 ↗ | 2BH7630-0A361-2 |
| Max. differential pressure (vacuum) | -500 mbar p.2 ↗ | 2BH7630-0A361-2 |
| Max. differential pressure (pressure) | 720 mbar p.2 ↗ | 2BH7630-0A361-2 |
| Sound level | 80 dB(A) p.2 ↗ | 2BH7630-0A361-2 |
| Weight | 121 kg p.2 ↗ | 2BH7630-0A361-2 |
| Rated frequency | 100 Hz p.2 ↗ | 2BH7630-0A371-2 |
| Rated voltage | 400 V p.2 ↗ | 2BH7630-0A371-2 |
| Rated current | 22,0 A p.2 ↗ | 2BH7630-0A371-2 |
| Rated motor power | 12,1 kW p.2 ↗ | 2BH7630-0A371-2 |
| Max. differential pressure (vacuum) | -500 mbar p.2 ↗ | 2BH7630-0A371-2 |
| Max. differential pressure (pressure) | 480 mbar p.2 ↗ | 2BH7630-0A371-2 |
| Sound level | 80 dB(A) p.2 ↗ | 2BH7630-0A371-2 |
| Weight | 109 kg p.2 ↗ | 2BH7630-0A371-2 |
| Rated frequency | 85 Hz p.2 ↗ | 2BH7630-0A366-2 |
| Rated voltage | 380 V p.2 ↗ | 2BH7630-0A366-2 |
| Rated current | 27,4 A p.2 ↗ | 2BH7630-0A366-2 |
| Rated motor power | 14,0 kW p.2 ↗ | 2BH7630-0A366-2 |
| Max. differential pressure (vacuum) | -560 mbar p.2 ↗ | 2BH7630-0A366-2 |
| Max. differential pressure (pressure) | 940 mbar p.2 ↗ | 2BH7630-0A366-2 |
| Sound level | 80 dB(A) p.2 ↗ | 2BH7630-0A366-2 |
| Weight | 121 kg p.2 ↗ | 2BH7630-0A366-2 |
| Rated voltage/frequency set point | 345 V / 87 Hz p.1 ↗ | frequency converter operation, delta connection |
Operating Limits
- Max. ambient/suction temperature for stated pressure differences: 25 °C p.1 ↗
- Performance tolerance: ±10 % p.1 ↗
- Minimum pulse frequency for frequency converter operation: 4 kHz p.1 ↗
- Minimum mains voltage for frequency converter: 380 V p.1 ↗
Type Code Decoder
| Position | Token | Meaning |
|---|---|---|
| 1-7 p.2 ↗ | 2BH7630 | Series and size (side channel blower 2BH7, size 630) |
| 8-9 p.2 ↗ | -0A | Version / motor variant |
| 10-12 p.2 ↗ | 361 / 371 / 366 / 376 / K66 / K76 | Motor and voltage variant code (e.g. 361: 100 Hz/400 V; 366: 85 Hz/380 V; K66: 85 Hz/400 V delta) |
| VFD type field p.2 ↗ | A–K | Frequency converter size (2FC4xxx-1) |
Ordering Data
| Ordering Code | Part No. | Variant / Code | Applies To | Note |
|---|---|---|---|---|
| 2BH7630-0A361-2 p.2 ↗ | 2BH7630-0A361-2 | 100 Hz, 400 V | 16.0 kW, 29.0 A | |
| 2BH7630-0A371-2 p.2 ↗ | 2BH7630-0A371-2 | 100 Hz, 400 V | 12.1 kW, 22.0 A | |
| 2BH7630-0A366-2 p.2 ↗ | 2BH7630-0A366-2 | 85 Hz, 380 V | 14.0 kW, 27.4 A | |
| 2BH7630-0A376-2 p.2 ↗ | 2BH7630-0A376-2 | 85 Hz, 380 V | 10.2 kW, 20.3 A | |
| 2BH7630-0AK66-2 p.2 ↗ | 2BH7630-0AK66-2 | 85 Hz, 400 V delta | 14.0 kW, 26.0 A | |
| 2BH7630-0AK76-2 p.2 ↗ | 2BH7630-0AK76-2 | 85 Hz, 400 V delta | 10.2 kW, 20.0 A |