Elmo Rietschle 2BH7630
Elmo Rietschle ·Made in Germany · In Active Production

Elmo Rietschle 2BH7630

Elmo Rietschle 2BH7630 — Side-Channel / Regenerative Ring Blowers with Max. differential pressure -500 mbar, Motor power 16 kW, Noise level 75…78 dB.

The 2BH7630 is a side-channel blower from the G-BH7 e series, supplied with an integrated frequency converter for variable-speed operation. It delivers up to 720 mbar differential pressure in pressure mode and 500 mbar in vacuum mode at 50 Hz, with a 12.1 kW rated motor. This modification is the higher-capacity unit within the series, intended for continuous industrial vacuum or pressure duty where flow and pressure must be electronically controlled.

Max. differential pressure
-500 mbar
Motor power
16 kW
Noise level
75…78 dB
Weight
121 kg

Elmo Rietschle G-BH7 Series — Model Comparison & Selection

Model Motor power, kWNoise level, dBMax. differential pressure, mbarWeight, kgCurrent, AVoltage, V
2BH7630 Current 1680-50012129400
2BH721 159-300214.2190–210
2BH7210 0.6363-270163.0 △ / 1.7 Y220-275 △ / 380-480 Y
2BH722 1.158480284.8 UU / 2.4 U190-210 UU / 380-420 U
2BH7220 0.8158-440244220-275 / 380-480 Y
2BH731 1.163-340242.8–5.5190-210 / 380-420
2BH7310 0.6358250—2.8200-240 / 345-415 Y
2BH732 1.364440333.2190-210 / 380-420
2BH7320 3.577-510486.5—
2BH741 1.363—266.3190–210
2BH7410 2.673-230335.2400
2BH742 1.864460383.9–7.8190-210 / 380-420
2BH7420 2.977-270456.5380
2BH751 1.868-340337.8 UU190-210 UU / 380-420 U
2BH7510 6.6784304312.7400
2BH752 2.564-5205012190-210 / 380-420
2BH7520 4.377-520578.7400 V (-15%) … 480 V (+1
2BH753 5.3699507217.1190–210
2BH7530 7.570-6108016.2400
2BH7610 5.880-4105512.7380
2BH7620 8.879-5307716.2400

Full specifications

Core Performance & Functional Specifications
Max. differential pressure -500 mbar
Motor power 16.0 kW
Noise level 80 dB(A)
50 Hz / 60 Hz: 75/78 dB(A)
Max differential pressure vacuum mfr 500 mbar (50 Hz)
Motor type mfr 3~ 50/60 Hz, IP55, Insulation material class F,
Max. differential pressure (Pressure) (alt var) mfr 720 mbar
Dimensions, Weight & Mechanical Design
Weight 121 kg
Weight approx. mfr 123 kg
Electrical, Power & Drive Specifications
Current 29.0 A
Frequency 100 Hz
Power supply 3~ 50/60 Hz, IP55, Insulation material class F, UL 1004 and CNA/CSA 22.2 No 68-09
Voltage 400 V
Rated mains voltage mfr 400 V (50 Hz)
Rated mains voltage mfr 480 V (60 Hz)
Rated motor current mfr 29.0 A (400 V)
Rated motor current mfr 27.4 A (380 V)
Max motor current mfr 10.2 A (50 Hz)
Typical motor power mfr 14.0 kW (50 Hz)
Rated motor power mfr 12.1 kW (50 Hz)
Mains frequency mfr 50/60 Hz
Rated motor current mfr 29.0 A
Operating Conditions, Environment & Protection
Protection rating IP55
Sound pressure level mfr 80 dB(A) (50 Hz)
Sound pressure level mfr 85 dB(A) (60 Hz)
Sound pressure level mfr 80 dB(A)

Description

Construction and series positioning

Operating behavior

Installation and control

Integration & Operating Notes

Electrical
Mains supply must match 400 V or 480 V and rated current

The motor is rated for 400 V at 50 Hz and 480 V at 60 Hz, with a rated current of 29.0 A at 400 V. Ensure the supply transformer and protection devices can handle the starting current and continuous load; undersized supply will cause voltage drop and converter faults.

Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN
Control & I/O
Frequency converter requires correct parameter set for the blower

The integrated frequency converter (variants 2FC4152-1□□00 to 2FC4223-1□□00) must be configured with the motor data of the 2BH7630. Incorrect parameterization can lead to overload, overheating or insufficient pressure; always verify the converter settings against the data sheet before commissioning.

Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN
Process Limits
Do not exceed 720 mbar pressure or 500 mbar vacuum differential

The maximum differential pressure is 720 mbar in pressure mode and 500 mbar in vacuum mode at 50 Hz. Operating beyond these limits will cause overheating and may damage the impeller or motor; install pressure relief or monitoring to keep the process within the envelope.

Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN
Cooling & Media
Ensure adequate cooling air flow around motor and converter

The motor and frequency converter dissipate heat; restricted airflow will cause overheating and reduced service life. Maintain the minimum clearance specified in the data sheet and avoid recirculating hot exhaust air into the intake.

Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN

Selection & Integration Q&A

When should I choose the 2BH7630 instead of a smaller model like 2BH7220?

Choose the 2BH7630 when you need higher pressure (up to 720 mbar) and flow than the smaller siblings can provide. The 2BH7220 is limited to lower performance; the 2BH7630 is the largest in the series and includes an integrated frequency converter for speed control.

What are the requirements for the power supply and protection when integrating this blower?

The blower requires a 400 V (50 Hz) or 480 V (60 Hz) supply with rated current of 29.0 A at 400 V. Use motor protection rated for the starting current and ensure the supply can handle the 16.0 kW continuous load. The integrated frequency converter must be configured for the motor data.

What maintenance and accessories are required for this blower?

Regular maintenance includes checking the impeller for debris, inspecting the frequency converter cooling, and verifying electrical connections. The base delivery does not include external filters, silencers, or flexible connectors; these must be ordered separately based on the application.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — G-BH7 2BH7630 side channel blower (EN)
Datasheet ·481,9 КБ ·2 pp.
View PDF