Induztr
Engineering Digest Document Viewer Related Models

Operating Instructions — VCS 200 vacuum pump (BA 236-EN, ed. 1.7 28/06/2022, EN)

Technical Reference Summary

Covered Models & Document Scope

This document covers the oil-flooded rotary vane vacuum pumps V-VCS 200 | 300 (standard design) and V-VCX 200 | 300 (increased water vapour compatibility). Both sizes (200 and 300) are covered in both variants. The V-VCX variant additionally features more water-steam/solvent-resistant functional parts, glass-fibre reinforced epoxy resin slide gates, increased gas ballast quantity, and an adjustable gas ballast valve with ball valve.

Section-by-Section Technical Breakdown

pp. 14-16
Product Overview and Functioning

Describes the construction and operating principle of the single-stage oil-flooded rotary vane vacuum pumps. Key components include the vacuum connection, inlet flange with non-return valve, oil separator element, gas ballast valve, oil sight glass, and cooling air paths. The V-VCX variant has increased water vapour compatibility and an adjustable gas ballast valve.

  • Single-stage oil-flooded rotary vane design with integrated mesh filter on suction side and oil mist separator on outlet side.
  • Integrated non-return valve prevents the evacuated system from being ventilated after pump stop for approx. 2 minutes.
  • Standard gas ballast valve prevents condensation of low quantities of water vapour when at operating temperature.
  • V-VCX variant: functional parts more resistant to water steam and solvents, glass-fibre reinforced epoxy resin slide gates, increased gas ballast quantity, higher oil sump temperature.
  • V-VCX includes an additional adjustable gas ballast valve with ball valve for variable gas ballast capacity.
pp. 16
Fields of Application

Defines the permissible intake pressure ranges for continuous operation and the nominal suction capacity. Also provides guidance on evacuation of closed systems, motor selection for higher intake pressures, and switching frequency limits.

  • Nominal suction power with unrestricted suction: 200 and 300 m³/h at 50 Hz.
  • Continuous vacuum intake pressure ranges: V-VCS 0.5 to 500 mbar (abs.); V-VCX 3.0 to 500 mbar (abs.).
  • When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity.
  • For continuous operation > 100 mbar (abs.), the next higher motor output should be used.
  • Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed motor winding and bearing temperature limits.
pp. 17-19
Installation

Covers preparation of installation, mechanical installation, pipe connection, oil level check, and motor connection. Specifies space requirements, ambient temperature limits, cooling air clearances, permissible back pressure, and electrical connection requirements.

  • Machine must be set up horizontally with max. inclination 1° in all directions.
  • Provide at least 50 cm space around the machine for maintenance work.
  • Cooling air inlets and outlets must be at least 30 cm away from adjacent walls.
  • Ambient temperature: min. +12 °C, max. +40 °C.
  • Exhaust air side counter pressure only permissible up to +100 mbar.
  • No filter may be installed on the exhaust air side; exhaust air opening must not be closed or restricted.
  • For parallel operation, an external non-return valve must be installed in the suction line upstream of each pump.
  • Motor electrical data: protection class IP 55, insulation class F, permissible tolerances ±5% voltage deviation and ±2% frequency deviation.
  • Electrical installation must be carried out by a qualified electrician observing EN 60204; motor must be safeguarded via a motor protection switch.
pp. 20-22
Commissioning and Decommissioning

Describes start-up checks, rotation direction verification, oil level check during operation, standstill procedures, decommissioning, storage, and recommissioning. Emphasizes safety checks before first start-up.

  • Installation check must confirm no transport damage, safe horizontal standing, correct pipe connections, tight screw/flange connections, and complete electrical installation.
  • Direction of rotation of the motor must correspond with the direction of rotation arrow on the motor flange.
  • Oil level must be checked through the oil sight glass and topped up if necessary.
  • For standstill times longer than two minutes, vent the connected suction line to atmospheric pressure.
  • Decommissioning and storage procedures are specified; recommissioning requires repeating start-up checks.
pp. 23-31
Maintenance and Repair

Provides the maintenance table, procedures for cleaning the vacuum pump and filters, lubricating oil specifications and oil change, oil separator element replacement, oil cooler and fan maintenance, motor and coupling inspection, and spare parts information.

  • Maintenance table defines intervals for inspection and maintenance works.
  • Mesh filter in suction flange and filter cartridge of gas ballast valve must be cleaned.
  • Lubricating oil must comply with ISO VG 100 as per DIN ISO 3448.
  • Oil separator elements must be changed when dirty.
  • Oil cooler and fan must be cleaned; fan renewed if necessary.
  • Coupling and coupling sleeve must be checked and replaced if defective or worn out.
  • Repairs only allowed by authorised workshops using original spare parts.
pp. 33-35
Errors

Contains a table of malfunctions with symptoms, causes, and remedies. Covers motor protection switch trips, insufficient pumping capacity, failure to reach final pressure, overheating, oil mist in exhaust air, strange noises, and water in lubricating oil.

  • Never put the pump back into operation after automatic shut-off without finding and remedying the cause.
  • Motor protection switch may trip due to incorrect mains voltage/frequency, incorrect terminal board connection, incorrect switch setting, cold oil, dirty oil separator elements, or excessive back pressure.
  • Insufficient pumping capacity can be caused by too long/narrow inlet pipe, leaks, dirty intake filter, or cold/too viscous oil.
  • Final pressure not reached due to leaks, incorrect oil viscosity, or dirty oil separator elements.
  • Overheating due to high ambient/inlet temperatures, obstructed cooling air, soiled oil cooler, or too viscous oil.
  • Visible oil mist in exhaust air due to incorrectly inserted oil separator elements, missing O-rings, unsuitable oil, or dirty separator elements.
  • Strange noises may indicate worn pump housing, vibrating vacuum adjustment valve, damaged blades, cold oil, too viscous oil, or defective coupling.
  • Water in lubricating oil requires installation of a water interceptor upstream or increased gas ballast.
pp. 37
Technical Data

Reference to chapter 10 for technical data including weight, sound pressure level, and other performance parameters. The actual data table is not included in the provided text.

  • Technical data are provided in chapter 10 of the manual.
  • Data sheet D236 contains technical data and characteristic curves.
  • Sound pressure level is specified in chapter 10.

Key Integration, Operating & Safety Requirements

Specification / Condition Engineering Implication Applies To
Nominal suction power with unrestricted suction is 200 and 300 m³/h at 50 Hz. p.16 ↗ Select pump size based on required pumping speed at 50 Hz; 60 Hz data available on data plate. V-VCS 200/300 and V-VCX 200/300
Continuous vacuum intake pressure ranges: V-VCS 0.5 to 500 mbar (abs.); V-VCX 3.0 to 500 mbar (abs.). p.16 ↗ Operation outside these ranges risks oil leaking through the outlet opening. V-VCS and V-VCX variants respectively
When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity of the vacuum pump. p.16 ↗ Size the evacuated volume accordingly to avoid operational issues. Whole series
For continuous operation > 100 mbar (abs.), the next higher motor output should be used. p.16 ↗ Motor selection must account for higher intake pressures to avoid overheating. Whole series
Ambient temperature and inlet temperature must be between 12 and 40 °C. p.8 ↗ Installation location must maintain this temperature range; contact manufacturer for outside range. Whole series
Permissible back pressure on the exhaust air side is up to +100 mbar. p.18 ↗ Exhaust piping must be sized to avoid exceeding this limit; no filters on exhaust side. Whole series
Machine must be set up horizontally with max. inclination 1° in all directions. p.17 ↗ Mounting surface must be plane and even; secure against tipping. Whole series
Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.17 ↗ Ensure sufficient clearance for cooling air flow to prevent overheating. Whole series
Provide at least 50 cm space around the machine for maintenance work. p.17 ↗ Installation layout must allow access for maintenance and pipe removal. Whole series
Motor protection class IP 55, insulation class F; permissible voltage deviation ±5%, frequency deviation ±2%. p.19 ↗ Verify mains supply quality and motor data plate before connection. Whole series
Lubricating oil must comply with ISO VG 100 as per DIN ISO 3448. p.26 ↗ Use only recommended oil types; incorrect viscosity can cause overheating or insufficient vacuum. Whole series
For parallel operation of multiple pumps, an external non-return valve must be installed in the suction line upstream of each pump. p.18 ↗ Prevents damage to a switched-off pump from operating pumps. Whole series
For standstill times longer than two minutes, vent the connected suction line to atmospheric pressure. p.18 ↗ Provide an air release position (e.g., ball valve) in the suction line. Whole series
Storage temperature range: -10 °C to +60 °C; relative air humidity max. 80%; storage not more than 6 months. p.13 ↗ Long-term storage (>3 months) requires preservation oil instead of operating oil. Whole series
An output reduction is noticeable when installed at more than 1000 m above sea level. p.17 ↗ Contact manufacturer for high-altitude installations. Whole series
Frequent switching at regular intervals of approx. 10 times per hour or higher ambient/inlet temperatures may exceed motor winding and bearing temperature limits. p.16 ↗ Contact manufacturer for such operating conditions. Whole series

Faults & Troubleshooting

Code / Symptom Possible Cause Remedy Note
Machine is switched off by the motor protection switch p.33 ↗ Mains voltage/ Frequency does not correspond with the motor data Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.33 ↗ Connection to motor terminal board is not correct Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.33 ↗ Motor protection switch is not set correctly Check by qualified electrician Chapter 5.5
Machine is switched off by the motor protection switch p.33 ↗ Motor protection switch is triggered too quickly Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per IEC 60947-4-1)
Machine is switched off by the motor protection switch p.33 ↗ Vacuum pump or its oil is too cold Note the ambient temperature and the inlet temperature Chapter 2.4
Machine is switched off by the motor protection switch p.33 ↗ The lubricating oil is too viscous The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Chapter 7.6
Machine is switched off by the motor protection switch p.33 ↗ The air oil separator elements are dirty. Change the oil separator elements Chapter 7.7
Machine is switched off by the motor protection switch p.33 ↗ The back pressure in the exhaust line is too high Check the hose and/or the pipe Chapter 5.3
Machine is switched off by the motor protection switch p.33 ↗ Permanent operation >100 mbar (abs.). Use next largest motor output Chapter 4.4
Pumping capacity is insufficient p.33 ↗ The inlet pipe is too long or too narrow Check the hose and/or the pipe Chapter 5.3
Pumping capacity is insufficient p.33 ↗ Leak on the inlet side of the vacuum pump or in the system Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Pumping capacity is insufficient p.33 ↗ The intake filter is dirty Clean or replace the intake filter Chapter 7.5
Final pressure (max. vacuum) is not reached p.34 ↗ Leak on the inlet side of the vacuum pump or in the system Check the pipework and screw connections for leaks and check for tight fit Chapter 7.2
Final pressure (max. vacuum) is not reached p.34 ↗ Incorrect oil viscosity The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Chapter 7.6
Machine gets too hot p.34 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.4
Machine gets too hot p.34 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Machine gets too hot p.34 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.8
Machine gets too hot p.34 ↗ Soiled oil cooler Clean the oil cooler and fan, renew the fan if necessary Chapter 7.8
Machine gets too hot p.34 ↗ The lubricating oil is too viscous The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Chapter 7.6
Machine gets too hot p.34 ↗ The air oil separator elements are dirty. Change the oil separator elements Chapter 7.7
Machine gets too hot p.34 ↗ The back pressure in the exhaust line is too high Check the hose and/or the pipe Chapter 5.3
Exhaust air contains visible oil mist p.34 ↗ The oil separator elements are not inserted correctly or the O rings are missing. Check that it is correctly seated Chapter 7.7
Exhaust air contains visible oil mist p.34 ↗ Unsuitable oil is being used Use suitable types Chapter 7.6
Exhaust air contains visible oil mist p.34 ↗ The air oil separator elements are dirty Change the oil separator elements Chapter 7.7
Exhaust air contains visible oil mist p.34 ↗ Ambient or inlet temperatures too high Ensure proper use Chapter 2.4
Exhaust air contains visible oil mist p.34 ↗ Cooling air supply is obstructed Check ambient conditions Chapter 5.1
Exhaust air contains visible oil mist p.34 ↗ Cooling air supply is obstructed Clean ventilation slots Chapter 7.2
The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.34 ↗ The pump housing is worn (chatter marks) Repair by manufacturer or authorised workshop Elmo Rietschle Service
The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.34 ↗ The vacuum adjustment valve (if available) is vibrating Replace the valve Chapter 7.11
The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.34 ↗ Blades are damaged Repair by manufacturer or authorised workshop Elmo Rietschle Service
The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.34 ↗ Vacuum pump or its oil is too cold Note the ambient temperature and the inlet temperature Chapter 2.4
The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.34 ↗ The lubricating oil is too viscous The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 Chapter 7.6
The machine makes a strange noise p.35 ↗ Coupling defective or coupling sleeve worn out Check and replace coupling / coupling sleeve Chapter 7.9.2
Water in lubricating oil p.35 ↗ Pump sucks in water Install water interceptor upstream of the pump —
Water in lubricating oil p.35 ↗ The pump sucks in more water vapour than is suitable for its water vapour compatibility Contact the manufacturer for increased gas ballast —
Water in lubricating oil p.35 ↗ Pump only works for a short time and therefore does not reach its normal operating temperature Let the pump continue to run with a closed suction side after extracting the water vapour until the water has evaporated from the oil —