Operating Instructions — VCS 40 vacuum pump (BA 238-EN, ed. 1.1 14/07/2023, EN)
Technical Reference Summary
Covered Models & Document Scope
This document covers the oil-flooded rotary vane vacuum pumps V-VCS 40, V-VCS 50, V-VCS 75 (standard design) and V-VCX 40, V-VCX 50, V-VCX 75 (increased water vapour compatibility). The VCX variant has functional parts more resistant to water steam and solvents, glass-fibre reinforced epoxy resin slide gates, increased gas ballast quantity, and a clearly increased oil sump temperature compared with the standard design.
Section-by-Section Technical Breakdown
Describes the construction of the V-VCS/VCX pumps and the layout of the data plate. The pumps are single-stage oil-flooded rotary vane vacuum pumps with integrated suction mesh filter, oil mist separator, fan cooling, non-return valve, and standard gas ballast valve. The data plate encodes model, serial number, year of construction, article number, speed, motor output, operating mode, pumping capacity and final pressure for 50/60 Hz.
- Main components: vacuum connection (A), exhaust air outlet (B), inlet flange with non-return valve (D), cooling air inlet/outlet (E/F), oil filling point (H), oil sight glass (I), oil discharge point (K), oil separator element (L), data plate (N), direction of rotation arrow (O), drive motor (P), hot surfaces >70 °C (Q), oil remover housing (T), gas ballast valve (U).
- Data plate fields: 1 model/size, 2 serial number, 3 year of construction, 4 data matrix barcode, 5 article No., 6 speed 50/60 Hz, 7 motor output 50/60 Hz, 8 operating mode, 9 pumping capacity 50/60 Hz, 10 final pressure (abs.) 50/60 Hz.
- Barcode encodes material number (MA), production order (PR) and serial number (SC).
- VCX variant: more resistant functional parts, glass-fibre reinforced epoxy resin slide gates, increased gas ballast quantity, higher oil sump temperature.
Defines the permissible intake pressure ranges for continuous operation and the maximum volume to be evacuated. It also gives guidance for frequent switching, high ambient temperatures, high altitude and outdoor installation.
- Continuous intake pressure range: V-VCS 0.5 to 500 mbar (abs.); V-VCX 3.0 to 500 mbar (abs.).
- When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity.
- For continuous operation >100 mbar (abs.), use the next higher motor output.
- Frequent switching (approx. 10 times per hour) or high ambient/inlet temperatures may exceed the excess temperature limit of motor winding and bearings; contact manufacturer.
- Outdoor installation requires protection from environmental influences, e.g. a protective roof.
The V-VCX pumps include an additional gas ballast valve that can be variably adjusted via a ball valve. Opening the ball valve increases gas ballast capacity for humid gases but reduces the maximum achievable end pressure.
- Standard gas ballast valve (1) and adjustable gas ballast valve (2) with ball valve (3).
- Open ball valve if necessary when pumping humid gases or gas-air mixtures.
- Increased gas ballast reduces the maximum reachable end pressure.
Specifies the conditions for the installation site and the mechanical installation requirements. The machine must be installed horizontally with maximum inclination 1° in all directions, secured against tipping, and provided with sufficient clearance for cooling and maintenance.
- Machine freely accessible from all sides; do not close ventilation grids and holes.
- Provide at least 40 cm space around the machine for maintenance.
- Cooling air inlets and outlets must be at least 30 cm away from adjacent walls; cooling air must not be recirculated.
- Ambient temperature min. +12 °C, max. +40 °C.
- Max. inclination 1° in all directions; floor must be plane and even; bearing surface must carry the machine weight and be at least the same size as the machine.
- Non-return valve must not be removed.
- Output reduction noticeable when installed at more than 1000 m above sea level; contact manufacturer.
- Installation on a firm base without anchoring is possible; on a substructure, fixing with flexible buffers is recommended.
Covers the connection of suction and exhaust pipes, including permissible back pressure, prohibition of exhaust-side filters, and precautions for parallel operation and standstill.
- Exhaust air opening must not be closed or restricted; no filter may be installed on the exhaust air side.
- Counter pressures on the exhaust air side are only permissible up to +100 mbar.
- Prevent liquids from accumulating in the exhaust line.
- Remove blind plugs at suction connection and exhaust air outlet before connecting.
- Only screw in pipes by hand; use flexible connections if necessary.
- For standstill times longer than two minutes, vent the connected suction line to atmospheric pressure (e.g. ball valve).
- For parallel operation, install an external non-return valve in the suction line upstream of each pump.
- Suction capacity is reduced if the inlet pipe is too narrow and/or too long.
The pumps are delivered with first oil filling; a dark colour due to graphite leaching is normal and does not affect performance. Oil level must be checked at the oil sight glass and topped up to the upper edge of the sight glass.
- Check oil level through oil sight glass (Fig. 2/I).
- Fill lubricating oil via oil filling point (Fig. 2/H) up to the upper edge of the sight glass.
- Close the oil filling point after filling.
Specifies the electrical connection requirements for the motor, including protection class, insulation class, tolerances and the need for a motor protection switch. Electrical installation must be carried out by a qualified electrician observing EN 60204.
- Motors comply with DIN EN 60034, protection class IP 55, insulation class F.
- Unless otherwise stated on the motor data plate: voltage tolerance ±5%, frequency tolerance ±2%.
- Motor must be safeguarded via a motor protection switch installed by the operating company.
- Main switch must be installed by the operating company.
- Direction of rotation must correspond with the direction of rotation arrow on the motor flange.
- Connection diagram is located in the terminal box (not existing for version with plug connection).
- Recommended: motor protection circuit breakers with delayed switch off due to temporary excess current when starting cold.
Before start-up, a series of installation checks must be carried out to ensure safe operation. The checks cover mechanical condition, horizontal alignment, pipe connections, electrical installation and installation room conditions.
- Check for no transport or assembly damage.
- Verify the vacuum pump stands safely on the substrate in a horizontal installation position.
- Check correct connection and leak tightness of inlet and outlet pipelines.
- Check tight fit of screw and flange connections.
- Verify electrical installation complies with the connection diagram.
- Check the installation room conditions.
Covers maintenance works including cleaning the vacuum pump, cleaning the mesh filter in the suction flange and the filter disc of the gas ballast valve, oil refilling and oil change, oil separator elements, motor and coupling. A maintenance table is provided.
- Maintenance table in chapter 7.2.
- Clean the mesh filter in the suction flange (7.5.1).
- Clean the filter disc of the gas ballast valve (7.5.2).
- Oil change and refilling procedures in 7.6.1 and 7.6.2.
- Oil separator elements in 7.7.
- Motor and coupling maintenance in 7.8.
- Repair/service and spare parts in 7.9 and 7.10.
Chapter 10 contains the technical data of the pumps. The data plate example shows for V-VCS 75: final pressure 0.50/0.50 mbar (abs.), pumping capacity 200.0/240.0 m³/h, speed 1465/1795 rpm, motor output 4.00/4.50 kW, operating mode S1.
- Example data plate V-VCS 75: final pressure 0.50/0.50 mbar (abs.) at 50/60 Hz.
- Pumping capacity 200.0/240.0 m³/h at 50/60 Hz.
- Speed 1465/1795 rpm at 50/60 Hz.
- Motor output 4.00/4.50 kW at 50/60 Hz.
- Operating mode S1.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Permissible ambient and inlet temperature range is 12 to 40 °C. p.8 ↗ | Operation outside this range requires consultation with the manufacturer; ensure installation room temperature is controlled. | V-VCS 40/50/75 and V-VCX 40/50/75 |
| Continuous intake pressure range: V-VCS 0.5 to 500 mbar (abs.); V-VCX 3.0 to 500 mbar (abs.). p.8 ↗ | Continuous operation outside these ranges risks oil leaking through the outlet opening. | V-VCS and V-VCX respectively |
| Maximum permissible back pressure on the exhaust side is +100 mbar. p.18 ↗ | Exhaust lines must be sized to avoid exceeding this limit; no filters may be installed on the exhaust side. | Whole series |
| When evacuating closed systems, the volume to be evacuated must be no more than 2% of the nominal pumping capacity. p.16 ↗ | Size the evacuated volume accordingly to avoid operational issues. | Whole series |
| For continuous operation >100 mbar (abs.), the next higher motor output should be used. p.16 ↗ | Motor selection must account for the continuous operating pressure. | Whole series |
| Maximum inclination during installation is 1° in all directions. p.17 ↗ | The machine must be installed horizontally; floor must be plane and even. | Whole series |
| Cooling air inlets and outlets must be at least 30 cm away from adjacent walls. p.17 ↗ | Ensure sufficient clearance to prevent recirculation of cooling air and overheating. | Whole series |
| Provide at least 40 cm space around the machine for maintenance works. p.17 ↗ | Installation layout must allow access for maintenance. | Whole series |
| Motor voltage tolerance ±5% and frequency tolerance ±2% unless otherwise stated on the motor data plate. p.19 ↗ | Verify mains network compliance before connection. | Whole series |
| Motors comply with DIN EN 60034, protection class IP 55, insulation class F. p.19 ↗ | Suitable for industrial environments; observe protection class when installed outdoors. | Whole series |
| Oil viscosity must comply with ISO VG 100 as per DIN ISO 3448. p.32 ↗ | Use only suitable lubricating oil to avoid excessive viscosity and motor overload. | Whole series |
| For standstill times longer than two minutes, vent the connected suction line to atmospheric pressure. p.18 ↗ | Provide an air release position (e.g. ball valve) in the suction line to avoid damage. | Whole series |
| For parallel operation, an external non-return valve must be installed in the suction line upstream of each pump. p.18 ↗ | Prevents a switched-off pump from being damaged by the operating pumps. | Whole series |
| Storage temperature range: -10 °C to +60 °C; relative air humidity max. 80%; storage not more than 6 months. p.13 ↗ | For long-term storage (more than 3 months), use preservation oil rather than operating oil. | Whole series |
| Output reduction is noticeable when installed at more than 1000 m above sea level. p.17 ↗ | Contact manufacturer for high-altitude installations. | Whole series |
| Example data plate V-VCS 75: final pressure 0.50/0.50 mbar (abs.), pumping capacity 200.0/240.0 m³/h, speed 1465/1795 rpm, motor output 4.00/4.50 kW at 50/60 Hz. p.15 ↗ | Reference values for the V-VCS 75 model; actual values per data plate. | V-VCS 75 |
| Nominal pumping capacity with free intake at 50 Hz: 40 m³/h (VCS 40), 50 m³/h (VCS 50), 70 m³/h (VCS 75). p.16 ↗ | Basis for sizing and for the 2% rule for evacuating closed systems. | V-VCS 40/50/75 |
| The non-return valve prevents the evacuated system from being ventilated after the pump has stopped for approx. 2 minutes. p.15 ↗ | The non-return valve must not be removed. | Whole series |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.32 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.32 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.32 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Chapter 5.5 |
| Machine is switched off by the motor protection switch p.32 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per IEC 60947-4-1) | |
| Machine is switched off by the motor protection switch p.32 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the inlet temperature | Chapter 2.4 |
| Machine is switched off by the motor protection switch p.32 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Machine is switched off by the motor protection switch p.32 ↗ | The oil separator elements are dirty. | Change the oil separator elements | Chapter 7.7 |
| Machine is switched off by the motor protection switch p.32 ↗ | The back pressure in the exhaust line is too high | Check the hose and/or the pipe | Chapter 5.3 |
| Machine is switched off by the motor protection switch p.32 ↗ | Permanent operation >100 mbar (abs.). | Use next largest motor output | Chapter 4.4 |
| Pumping capacity is insufficient p.32 ↗ | The inlet pipe is too long or too narrow | Check the hose and/or the pipe | Chapter 5.3 |
| Pumping capacity is insufficient p.32 ↗ | Leak on the inlet side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and check for tight fit | Chapter 7.2 |
| Pumping capacity is insufficient p.32 ↗ | The intake filter is dirty | Clean or replace the intake filter | Chapter 7.5 |
| Final pressure (max. vacuum) is not reached p.33 ↗ | Leak on the inlet side of the vacuum pump or in the system | Check the pipework and screw connections for leaks and check for tight fit | Chapter 7.2 |
| Final pressure (max. vacuum) is not reached p.33 ↗ | Incorrect oil viscosity | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Machine gets too hot p.33 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Machine gets too hot p.33 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Machine gets too hot p.33 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.4 |
| Machine gets too hot p.33 ↗ | Fan dirty and damaged | Clean the fan, replace the fan, if necessary | Chapter 7.8.2 |
| Machine gets too hot p.33 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| Machine gets too hot p.33 ↗ | The oil separator elements are dirty. | Change the oil separator elements | Chapter 7.7 |
| Machine gets too hot p.33 ↗ | The back pressure in the exhaust line is too high | Check the hose and/or the pipe | Chapter 5.3 |
| Exhaust air contains visible oil mist p.33 ↗ | The oil separator elements are not inserted correctly or the O rings are missing. | Check that it is correctly seated | Chapter 7.7 |
| Exhaust air contains visible oil mist p.33 ↗ | Unsuitable oil is being used | Use suitable types | Chapter 7.6 |
| Exhaust air contains visible oil mist p.33 ↗ | The oil separator elements are dirty | Change the oil separator elements | Chapter 7.7 |
| Exhaust air contains visible oil mist p.33 ↗ | Ambient or inlet temperatures too high | Ensure proper use | Chapter 2.4 |
| Exhaust air contains visible oil mist p.33 ↗ | Cooling air supply is obstructed | Check ambient conditions | Chapter 5.1 |
| Exhaust air contains visible oil mist p.33 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Chapter 7.2 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.33 ↗ | The pump housing is worn (chatter marks) | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.33 ↗ | The vacuum adjustment valve (if available) is vibrating | Replace the valve | Chapter 7.10 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.33 ↗ | The Blades are damaged | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.33 ↗ | Vacuum pump or its oil is too cold | Note the ambient temperature and the inlet temperature | Chapter 2.4 |
| The machine makes a strange noise (The blades making a hammering noise when starting from cold is normal if it disappears within two minutes as the operating te p.33 ↗ | The lubricating oil is too viscous | The oil viscosity must comply with ISO VG 100 as per DIN ISO 3448 | Chapter 7.6 |
| The machine makes a strange noise p.34 ↗ | Coupling defective or coupling sprocket worn out | Check and replace coupling / coupling sprocket | Chapter 7.8.2 |
| Water in lubricating oil p.34 ↗ | Pump sucks in water | Install water interceptor upstream of the pump | — |
| Water in lubricating oil p.34 ↗ | The pump sucks in more water vapour than is suitable for its water vapour compatibility | Contact the manufacturer for increased gas ballast | Elmo Rietschle Service |
| Water in lubricating oil p.34 ↗ | Pump only works for a short time and therefore does not reach its normal operating temperature | Let the pump continue to run with a closed suction side after extracting the water vapour until the water has evaporated from the oil | — |