Operating Instructions — BA 261 (BA 261, EN)
Technical Reference Summary
Covered Models & Document Scope
This document covers the dry running rotary vane vacuum pumps V-VTR 100 and V-VTR 140 (V-Series), including their setup, installation, commissioning, maintenance, troubleshooting and technical data. It applies to the pump and motor combination as delivered, with standard flanged three-phase motors. Variants include plug-connection version (motor terminal box connection diagram not applicable) and accessory blow-out filter cartridge. Ordering codes are not explicitly listed; spare parts are ordered per spare parts list E 261.
Section-by-Section Technical Breakdown
Describes the main components and data plate of the V-VTR 100/140, the functional description including vacuum regulating valve, and the areas of application. The pumps are suitable for evacuating closed systems and permanent vacuum in the intake pressure range 150–1000 mbar (abs.), with pumping capacities of 100 and 140 m³/h at 50 Hz.
- Components include vacuum connection, exhaust air outlet, vacuum regulating valve, cooling air inlet/outlet, inlet grating, greasing plate, data plate, rotation direction plate, drive motor, filter housing, maintenance plate.
- Data plate shows type/size, year of construction, motor design, serial number, item number, final pressure, pumping capacity 50/60 Hz, speed 50/60 Hz, motor output 50/60 Hz, operating mode.
- Vacuum regulating valve sets vacuum to required values with an upper limit.
- Suitable for air with relative humidity 30–90%; ambient and suction temperature 5–40°C.
- Frequent switching (about 10 times/hour) or high ambient/intake temperatures may exceed motor winding and bearing temperature limits; contact manufacturer.
Covers preparation for installation, mounting requirements, pipe connection, control and relief valve, and motor electrical connection. Specifies clearances, foundation conditions, pipe length limits, and electrical supply tolerances.
- Machine must be freely accessible; do not close ventilation grids; cooling air inlets/outlets at least 30 cm from adjacent walls; minimum 40 cm in front of filter housing and inlet grating for maintenance.
- Install horizontally on a level, straight foundation able to bear the machine weight; anchoring not required on firm base; flexible buffers recommended on substructure.
- Connect pipes by hand only; if suction pipe has same cross-section and is longer than 3 m, install a non-return valve to avoid reverse operation.
- Do not operate without the standard control and relief valve; exceeding permissible final compression pressure may damage the machine.
- Electrical installation per EN 60204 by specialist electrician; motor protection switch required; cable fitting for strain relief; motor IP55, insulation class F, DIN EN 60034.
- Permissible without derating: ±5% voltage deviation, ±2% frequency deviation.
Provides procedures for initial commissioning, checking rotation direction, decommissioning/storing, and re-commissioning. Includes safety notes on hot surfaces, noise, and waiting for the machine to stop before restart.
- Check rotation direction by briefly starting motor (max. two seconds); when looking at motor fan, it must rotate clockwise.
- Use a phase sequence indicator to check direction; reverse operation may damage or break blades.
- Decommissioning: switch off, close cut-off devices, disconnect power, depressurise slowly, remove pipes, seal connections with adhesive foil, insert desiccant bag in filter housing.
- Re-commissioning: check condition, remove desiccant bag, follow installation and commissioning sections.
Defines maintenance intervals and procedures for lubrication, blade inspection/replacement, air filtering, coupling check, repair/service, and spare parts ordering. Includes specific wear limits for blades and grease quantities.
- Monthly: check pipes/screws for leaks, terminal box and cable inlets, clean regulating valve and ventilation slots.
- 20,000 h: change motor-side bearing (A bearing); 3,000 h: lubricate B bearing with 4 g grease (no later than one year).
- Blade check first after 3,000 h, then every 1,000 h; minimum height >26 mm (V-VTR 100) and >32 mm (V-VTR 140); minimum thickness >2.5 mm; replace as a set.
- Clean filter cartridges monthly by blowing from inside out; replace every six months.
- Check coupling sprocket at least once a year; replace if worn or damaged; do not operate without flywheel mass.
- Use only original spare parts; spare parts list E 261.
Troubleshooting table listing faults, probable causes, and corrective actions with references to relevant sections. Covers motor protection tripping, insufficient pumping capacity, failure to reach final pressure, overheating, and abnormal noise.
- Faults include machine switched off by motor protection switch, insufficient pumping capacity, final pressure not reached, machine gets too hot, abnormal noise.
- Causes include incorrect mains voltage/frequency, wiring errors, dirty filters/valves, leaking system, worn blades, obstructed cooling, worn housing.
- Remedies include checking electrical connection, cleaning/replacing filters and valves, replacing blades, repairing by manufacturer.
- Contact Elmo Rietschle Service for other malfunctions.
Lists sound pressure and sound power levels, weight, dimensions, and vacuum connection size for V-VTR 100 and V-VTR 140. Additional data available in data sheet D 261.
- Sound pressure level (max.) at 50 Hz: 82 dB(A) for V-VTR 100, 87 dB(A) for V-VTR 140; at 60 Hz: 84/89 dB(A); tolerance ±3 dB(A).
- Sound power level at 50 Hz: 92/97 dB(A); at 60 Hz: 96/99 dB(A).
- Weight: 122 kg (V-VTR 100), 127 kg (V-VTR 140); length 842/859 mm; width 406 mm; height 368 mm.
- Vacuum connection: G 1 1/4 for both models.
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Ambient and suction temperature must be between 5 and 40°C. p.7 ↗ | Operation outside this range requires consultation with manufacturer; ensure installation environment stays within limits. | V-VTR 100 and V-VTR 140 |
| Permissible media: air with relative humidity 30–90%; non-explosive, non-inflammable, non-aggressive, non-poisonous dry gases and gas-air mixtures. p.7 ↗ | Do not use for explosive, flammable, aggressive, poisonous media, dust (ATEX zone 20-22), solvents, oxygen, damp air, water vapour, oil traces. | V-VTR 100 and V-VTR 140 |
| Back pressure on outlet side must not exceed +0.1 bar. p.7 ↗ | Ensure exhaust line is adequately sized and free from restrictions to avoid exceeding limit. | V-VTR 100 and V-VTR 140 |
| Cooling air inlets and outlets must be at least 30 cm from adjacent walls; minimum 40 cm in front of filter housing and inlet grating for maintenance. p.14 ↗ | Plan installation layout to provide sufficient clearance for cooling and maintenance access. | V-VTR 100 and V-VTR 140 |
| With connection pipes of same cross-section as machine connection and longer than 3 m, a non-return valve must be installed. p.15 ↗ | Prevents reverse operation when machine stops; select and install suitable non-return valve in suction line. | V-VTR 100 and V-VTR 140 |
| Motor electrical data: DIN EN 60034, protection class IP 55, insulation class F. p.16 ↗ | Verify mains supply matches motor data plate; use appropriate motor protection switch with delayed switch-off. | V-VTR 100 and V-VTR 140 |
| Permissible supply deviation without derating: ±5% voltage, ±2% frequency. p.16 ↗ | Ensure site power quality within these limits; otherwise consult manufacturer for derating. | V-VTR 100 and V-VTR 140 |
| Rotation direction: when looking at motor fan, it must rotate clockwise; check by briefly starting motor (max. two seconds). p.18 ↗ | Incorrect rotation can damage or break blades; use phase sequence indicator to verify. | V-VTR 100 and V-VTR 140 |
| Motor-side bearing (A bearing) must be replaced after 20,000 operating hours or 2.5 years (3-shift operation). p.20 ↗ | Plan bearing replacement as preventive maintenance; use qualified professional or authorised workshop. | V-VTR 100 and V-VTR 140 |
| B bearing (side facing away from motor) must be lubricated with 4 g of grease after 3,000 operating hours but no later than one year. p.20 ↗ | Use recommended grease Klüber Petamo GY193 or equivalent; do not overfill grease reservoir. | V-VTR 100 and V-VTR 140 |
| Blade minimum height: >26 mm for V-VTR 100, >32 mm for V-VTR 140; minimum thickness >2.5 mm. p.20 ↗ | Check blades first after 3,000 h, then every 1,000 h; replace entire set if limits reached. | V-VTR 100 and V-VTR 140 |
| Filter cartridges must be cleaned monthly by blowing from inside out and replaced every six months. p.22 ↗ | Maintain air filtering to prevent power loss and machine damage; wear goggles and dust mask when using compressed air. | V-VTR 100 and V-VTR 140 |
| Coupling sprocket must be checked at least once a year; replace if worn or damaged. p.23 ↗ | Defective sprocket may lead to rotor shaft breaking; do not operate without flywheel mass. | V-VTR 100 and V-VTR 140 |
| Sound pressure level (max.) at 50 Hz: 82 dB(A) for V-VTR 100, 87 dB(A) for V-VTR 140; at 60 Hz: 84/89 dB(A), tolerance ±3 dB(A). p.28 ↗ | Use ear protection when spending long time near running machine. | V-VTR 100 and V-VTR 140 |
| Weight: 122 kg (V-VTR 100), 127 kg (V-VTR 140); dimensions: length 842/859 mm, width 406 mm, height 368 mm. p.28 ↗ | Ensure lifting equipment and foundation can handle weight; length and weight may vary with motor manufacturer. | V-VTR 100 and V-VTR 140 |
| Vacuum connection: G 1 1/4 for both models. p.28 ↗ | Use compatible pipe fittings; screw pipes in by hand only. | V-VTR 100 and V-VTR 140 |
| Pumping capacity with unrestricted suction: 100 m³/h (V-VTR 100) and 140 m³/h (V-VTR 140) at 50 Hz. p.13 ↗ | Select model based on required flow; refer to data sheet D 261 for capacity vs. intake pressure. | V-VTR 100 and V-VTR 140 |
| Permanent vacuum range: 150–1000 mbar (abs.). p.13 ↗ | Ensure application vacuum level falls within this range for continuous operation. | V-VTR 100 and V-VTR 140 |
Faults & Troubleshooting
| Code / Symptom | Possible Cause | Remedy | Note |
|---|---|---|---|
| Machine is switched off by the motor protection switch p.26 ↗ | Mains voltage/ Frequency does not correspond with the motor data | Check by qualified electrician | Section 5.5 |
| Machine is switched off by the motor protection switch p.26 ↗ | Connection to motor terminal board is not correct | Check by qualified electrician | Section 5.5 |
| Machine is switched off by the motor protection switch p.26 ↗ | Motor protection switch is not set correctly | Check by qualified electrician | Section 5.5 |
| Machine is switched off by the motor protection switch p.26 ↗ | Motor protection switch is triggered too quickly | Use a motor protection switch with an overload-dependent delayed switch off that takes into consideration the short term excess current at start up (version with short circuit and overload trigger as per VDE 0660 Part 2 or IEC 947-4) | |
| Machine is switched off by the motor protection switch p.26 ↗ | The blow out filter cartridge (accessory) is dirty. | Clean or replace the filter cartridges | Section 7.2.3, Section 7.4 |
| Machine is switched off by the motor protection switch p.26 ↗ | The regulating valve is dirty so that the permissible vacuum value is exceeded. | Clean or replace the regulating valve | Section 7.2, Section 7.4 |
| Pumping capacity is insufficient p.26 ↗ | The intake filter is dirty | Clean or replace the intake filter | Section 7.2.3, Section 7.4 |
| Pumping capacity is insufficient p.26 ↗ | The suction pipe is too long or too narrow | Check the hose or the pipe | Section 5.3 |
| Pumping capacity is insufficient p.26 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and to ensure that they are firmly seated. | Section 7.2 |
| Pumping capacity is insufficient p.26 ↗ | Blades are damaged | Replace blades | Section 7.2.2, Section 7.4 |
| Final pressure (max. vacuum) is not reached p.27 ↗ | Machine or system leaking | Check the pipework and screw connections for leaks and to ensure that they are firmly seated. | Section 7.2 |
| Final pressure (max. vacuum) is not reached p.27 ↗ | Blades are worn or damaged | Replace blades | Section 7.2.2, Section 7.4 |
| Machine gets too hot p.27 ↗ | Ambient or intake temperature is too high | Ensure it is being used properly | Section 2.3 |
| Machine gets too hot p.27 ↗ | Cooling air supply is obstructed | Check environmental conditions | Section 5.1 |
| Machine gets too hot p.27 ↗ | Cooling air supply is obstructed | Clean ventilation slots | Section 7.2 |
| Machine gets too hot p.27 ↗ | The blow out filter cartridge (accessory) is dirty. | Clean or replace the filter cartridges | Section 7.2.3, Section 7.4 |
| Machine gets too hot p.27 ↗ | The regulating valve is dirty so that the permissible vacuum value is exceeded. | Clean or replace the regulating valve | Section 7.2, Section 7.4 |
| The machine makes a abnormal noise p.27 ↗ | The compressor housing is worn (chatter marks) | Repair by manufacturer or authorised workshop | Elmo Rietschle Service |
| The machine makes a abnormal noise p.27 ↗ | The regulating valve is vibrating | Replace the valve | Section 7.4 |
| The machine makes a abnormal noise p.27 ↗ | Blades are damaged | Replace blades | Section 7.2.2, Section 7.4 |