Introduces the Unistat P525 unit and its main features
Specp. 2
Lists technical data according to DIN 12876 standard
p. 2table, 22 rows
p. 1table, 28 rows
Technical data according to DIN 12876
Parameter
Value
Delivery at 1,0 bar
66 l/min
Delivery at 1,5 bar
57 l/min
Delivery at 2,0 bar
46 l/min
Delivery at 2,5 bar
32 l/min
Pump connection
M30x1,5 male
max. permissible kin. viscosity
50 mm²/s
min. filling capacity
5,1 l
Filling capacity expansion tank
18 l
Overall dimensions Temperature Control Unit WxDxH
1290x795x1377 mm
Dimensions of External Transformer WxDxH
253x560x602 mm
Weight External Transformer
135 kg
sound pressure level +/- 4 dB(A)
56 dB(A)
Power supply factory configured (3 Phase)
208V 3~ 60Hz
Input Voltage External Transformer
208V 3~ 60Hz
Output Voltage External Transformer
440V 3~ 60Hz
Max. current temp. control unit with external transformer
45 A
Fuse input voltage external transformer
3x50A
Pressure equipment category
Art. 4.3 PED
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.:
1.1/24
Delivery at 1,0 bar; Technical details and dimensions are subject to change. No liability is accepted for errors or omissions. Illustrations can deviate from the original.
Unistat P525 Technical data according to DIN 12876
Characteristic
Value
Operating temperature range
-55...250 °C
Temperature stability at -10°C
0,01 K
temperature set point / display
5,7" colour Touchscreen
Resolution of display
0,01 K
Internal temperature sensor
Pt100
Sensor external connection
Pt100
Interface digital
Ethernet, USB (Host u. Device), RS232
digital input
ECS ONE
digital output
POKO ONE
Alarm message
optic, acoustic, relay
Safety classification
III / FL
Heating power
6 kW
Cooling power with Thermooil at 250°C
10 kW
Cooling power with Thermooil at 200°C
10 kW
Cooling power with Thermooil at 100°C
10 kW
Cooling power with Thermooil at 20°C
10 kW
Cooling power with Ethanol at 0°C
7 kW
Cooling power with Ethanol at -20°C
4,2 kW
Cooling power with Ethanol at -40°C
1,5 kW
Cooling power with Ethanol at -50°C
0,65 kW
Refrigeration machine
air-cooled, CFC- and HCFC-free
Refrigerant (ASHRAE, GHS)
R-452A (A1, H280)
Global Warming Potential (GWP)
2141
UN-number
UN 2857
Circulation pump
MK pump
max. delivery
82 l/min
max. delivery pressure
3 bar
Delivery at 0,5 bar
75 l/min
Engineering Facts
14 facts · every claim linked to a page
Selection
The unit is a refrigerated heating circulator with a magnetic-coupled stainless steel pump and is suitable for both externally closed and externally open applications.
Determines whether the circulator can serve open bath or external loop configurations without additional hardware.
Source
“Refrigerated Heating Circulator with air-cooled cooling machine and optical level indicator. Magnetic coupled circulation pump made of stainless steel.”
Selection
The P models use a high-discharge-pressure pump intended for applications with high pressure drops such as flow-through chemistry or semiconductor industry.
Confirms the pump head is adequate for restrictive external circuits with significant pressure loss.
Source
“Unistat „P“ Models: Circulating pumps with a high discharge pressure for applications with high pressure drops, e.g. in the Flow-Through chemistry or in the Semicon industry.”
Installation
The temperature control unit requires an external transformer supplied as standard to provide the required voltage.
The transformer must be accommodated and wired on site, affecting footprint and electrical installation.
Source
“the required voltage is provided using a external transformer (supplied as standard)”
Installation
The external transformer is a separate heavy component with its own dimensions and weight that must be planned for.
Space and floor loading must be reserved for the transformer in addition to the main unit.
Source
“Dimensions of External Transformer WxDxH 253x560x602 mm”
Installation
The external transformer weighs 135 kg and must be handled and positioned accordingly.
Requires suitable lifting and floor support during installation.
Source
“Weight External Transformer 135 kg”
Installation
The input voltage of the external transformer is 208V 3~ 60Hz and the output is 440V 3~ 60Hz.
Site power must match the 208V three-phase input; the 440V output feeds the temperature control unit.
Source
“Output Voltage External Transformer 440V 3~ 60Hz”
Installation
The input side of the external transformer requires 3x50A fuses.
Branch circuit protection must be sized to 50A per phase on the transformer input.
Source
“Fuse input voltage external transformer 3x50A”
Installation
The maximum current of the temperature control unit with external transformer is 45 A.
Cable and protection ratings on the transformer output must accommodate 45 A.
Source
“Max. current temp. control unit with external transformer 45 A”
Installation
External branch circuit protection according to UL 489 is required.
The installer must provide UL 489 listed branch protection; it is not included.
Source
“External branch circuit protection according to UL 489 required.”
Safety
Leakage current exceeds 3.5 mA, which affects protective earth and RCD selection.
Standard 30 mA RCDs may nuisance-trip; earth connection and protection must be designed for high leakage.
Source
“Attention: leakage current > 3,5mA”
Installation
Three-phase devices drawing less than 63A are supplied with cable but without a plug.
A suitable plug or direct connection must be procured and installed on site.
Source
“Three-phase devices with current consumption less than 63A --> with cable, without plug”
Operation
Cooling capacity is rated at 20°C room temperature and may drop if ambient temperature rises.
Performance margins must account for actual ambient conditions in the installation room.
Source
“Output data valid for: Room temperature 20°C. If the ambient temperature rises, the cooling capacity may drop.”
Operation
The permissible ambient temperature range is 5°C to 40°C.
The room must stay within this range for reliable operation and rated performance.
Source
“max. ambient temperature 40 °C”
Installation
The pump connection is M30x1.5 male with bore shape Y (60°) per DIN 3863 and mating ball socket and sleeve nut per DIN 3863/3870.
External hoses and fittings must match this thread and DIN geometry to avoid leaks.