Product name and general introduction to the Unistat T305 HT unit
Specp. 2
Technical data according to DIN 12876 for the unit
p. 1table, 34 rows
Technical data according to DIN 12876
Parameter
Value
Order-No.
1003.0049.01
Operating temperature range
65... 300 °C
Temperature stability at 70°C
0,01 K
temperature set point / display
5,7" colour Touchscreen
Resolution of display
0,01 K
Internal temperature sensor
Pt100
External sensor
Pt100
Interface digital
Ethernet, USB (Host u. Device), RS232
digital input
ECS ONE
digital output
POKO ONE
Alarm message
optic, acoustic, relay
Safety classification
III / FL
Heating power at 240V
3 kW
Heating power at 230V
3 kW
Heating power at 220V
3 kW
Heating power at 208V
2,7 kW
Heating power at 200V
2,5 kW
Cooling power at 300°C
3,2 kW
Cooling power at 200°C
2,3 kW
Cooling power at 100°C
0,6 kW
Circulation pump: max. delivery
45 l/min
max. delivery pressure
0,9 bar
Pump connection
M24x1,5 male
max. permissible kin. viscosity
50 mm²/s
min. filling capacity
3,5 l
Filling capacity expansion tank
4,5 l
Overall dimensions WxDxH **
425x250x631 mm
Net weight
42 kg
Power supply requirement
200-240V 1~/2~ 50/60Hz
Pressure equipment category
Art. 4.3 PED
Degree of Protection
IP20
min. ambient temperature
5 °C
max. ambient temperature
40 °C
from Serial-No.
1.0/24
** Overall dimensions WxDxH
Engineering Facts
14 facts · every claim linked to a page
Selection
The unit covers 65 to 300 °C, so it is only suitable for high-temperature closed-loop or open-bath duty, not for sub-ambient work.
Defines the process window and excludes applications requiring cooling below 65 °C.
Source
“Operating temperature range
65... 300 °C”
Installation
The electrical supply must be 200–240 V single- or two-phase at 50/60 Hz, so the site must provide the correct branch circuit and plug configuration.
Determines site power availability, cable/plug selection and branch protection before ordering.
Source
“Power supply requirement
200-240V 1~/2~ 50/60Hz”
Installation
External branch circuit protection to UL 489 is mandatory, so the installer must provide a listed breaker ahead of the unit.
Affects electrical panel design and compliance sign-off during installation.
Source
“External branch circuit protection according to UL 489 required.”
Installation
Single- and two-phase units are delivered with a country-specific plug only if specified at order, so the plug type must be stated on the purchase order.
Prevents a missing or wrong plug on delivery and avoids site rework.
Source
“Single / two-phase devices (100V to 240V) --> with power cable and country-specific plug (please specify when ordering)”
Installation
The pump connection is M24x1.5 male with Y-bore and DIN 3863 ball-socket hoses, so mating hoses and fittings must match this standard.
Ensures correct hose/fitting procurement and leak-free connection at commissioning.
Source
“Pump connection
M24x1,5 male”
Installation
The note specifies Y-bore pump connections to DIN 3863 and ball-socket/sleeve-nut hoses to DIN 3863/3870, so non-matching fittings will not seal.
Defines the exact mating geometry for pipework and flexible hoses.
Source
“Pump connections: Bore shape Y (60°) according to DIN 3863, pipework/flexible tempering hoses: Ball socket according to DIN 3863, sleeve nut according to DIN 3870.”
Operation
The maximum permissible kinematic viscosity is 50 mm²/s, so the thermofluid must be selected to stay below this at the lowest operating temperature.
Prevents pump overload and poor circulation when choosing the heat-transfer fluid.
Source
“max. permissible kin. viscosity
50 mm²/s”
Operation
Minimum filling capacity is 3.5 l and the expansion tank holds 4.5 l, so the loop volume and expansion allowance must be checked before filling.
Ensures sufficient fluid volume and expansion space to avoid cavitation or overflow.
Source
“min. filling capacity
3,5 l”
Installation
The unit is rated IP20, so it must be installed in a dry indoor location protected from water ingress.
Restricts installation environment and rules out washdown or outdoor siting.
Source
“Degree of Protection
IP20”
Installation
Ambient temperature must stay between 5 and 40 °C, so the room HVAC and placement near heat sources must be considered.
Affects room selection and derating/performance expectations at site.
Source
“min. ambient temperature
5 °C
max. ambient temperature
40 °C”
Performance
Cooling capacity drops from 3.2 kW at 300 °C to 0.6 kW at 100 °C, so heat-removal capability must be sized against the actual process temperature.
Prevents oversizing expectations and ensures the cooler can handle the process heat load at low end of range.
Source
“Cooling power at 100°C
0,6 kW”
Performance
The pump delivers up to 45 l/min at 0.9 bar, so external loop pressure drop must be checked against this curve.
Determines whether the circulation pump can serve the intended external circuit.
Source
“max. delivery
45 l/min”
Compliance
The unit is classified III / FL to DIN 12876, so it is suitable for flammable liquids only under the conditions of that classification.
Governs whether the unit may be used with flammable thermofluids and what safety measures apply.
Source
“Safety classification
III / FL”
Compliance
The pressure equipment is categorized under Art. 4.3 PED, so the PED assessment route and documentation must be confirmed for the installation.
Affects CE/PED compliance paperwork and acceptance at site.