Guides selection of the appropriate IDP dry scroll pump
Orderingpp. 8-9
Provides ordering codes and part numbers for pumps and accessories
Servicesp. 10
Highlights service, support, and partnership with Agilent
p. 8table, 39 rows
p. 9table, 23 rows
p. 7table, 6 rows
Ordering information — Agilent IDP Dry Scroll Pumps
Description
Part number
IDP-3, 1φ, 220 V, 50/60 Hz
IDP3A01
IDP-3, 1φ, 115 V, 60 Hz
IDP3B01
IDP-3, 1φ, 100 V, 50/60 Hz
IDP3C01
IDP-3, 24 VDC
IDP3D01
With inlet isolation valve
IDP-3, 1φ, 220 V, 50/60 Hz
IDP3A21
IDP-3, 1φ, 115 V, 60 Hz
IDP3B21
IDP-3, 1φ, 100 V, 50/60 Hz
IDP3C21
IDP-3, 24 VDC
IDP3D21
Service part numbers
IDP-3 tip seal replacement kit
IDP3TS
Accessory part numbers
Exhaust silencer kit
EXSLRIDP3
Inlet trap
SCRINTRPNW16
Vibration isolation kit
IDP3VIBISOKIT
IDP-7
Description
Part number
IDP-7
X3807-64000
IDP-7 with inlet isolation valve
X3807-64010
Service part numbers
IDP-7/10 tip seal replacement kit
X3807-67000
Accesory part numbers
Exhaust silencer kit
X3807-68003
Purge kit
X3807-68004
Gas ballast kit
X3807-68008
Inlet trap
SCRINTRPNW25
Vibration isolation kit
SH110VIBISOKIT
IDP-10
Description
Part number
IDP-10
X3810-64000
IDP-10 with inlet isolation valve
X3810-64010
Service part numbers
IDP-7/10 tip seal replacement kit
X3807-67000
Accesory part numbers
Exhaust silencer kit
X3807-68003
Purge kit
X3807-68004
Gas ballast kit
X3807-68008
Inlet trap
SCRINTRPNW25
Vibration isolation kit
SH110VIBISOKIT
Таблица приведена как напечатана: три отдельные секции (IDP-3, IDP-7, IDP-10), каждая со своими заголовками Description / Part number; строки-заголовки секций (Service part numbers, Accessory part numbers) оставлены с пустым Part number.
Ordering information — Agilent IDP Dry Scroll Pumps
Description
Part number
IDP-15
X3815-64000
IDP-15 with inlet isolation valve
X3815-64010
Service part numbers
IDP-15 tip seal replacement kit
X3815-67000
Accesory part numbers
Exhaust silencer kit
EXSLRSH110
Purge kit
X3807-68004
Gas ballast kit
X3807-68008
Inlet trap
SCRINTRPNW25
IDP-35
X3835-64011
IDP-35 with Gauge
X3835-64010
IDP-35 with Inlet Valve
X3835-64001
IDP-35 with Inlet Valve and Gauge
X3835-64000
Accesory part numbers
Inlet HEPA filter, NW40
SCRINTRPNW40
HEPA filter, NW25
SCRINTRPNW25
IDP-45
X3845-64011
IDP-45 with Gauge
X3845-64010
IDP-45 with Inlet Valve
X3845-64001
IDP-45 with Inlet Valve and Gauge
X3845-64000
Accesory part numbers
Inlet HEPA filter, NW40
SCRINTRPNW40
HEPA filter, NW25
SCRINTRPNW25
How to select your Agilent IDP dry scroll vacuum pump — Agilent IDP Dry Scroll Pumps
60 Hz
1.3 x 10-² mbar
1.0 x 10-² Torr
50 Hz
1.3 x 10-² mbar
1.0 x 10-² Torr
0.75 HP (560 W)/
100-115; 220-230 VAC
- General laboratory vacuum
- Thin film deposition
- LED, bulb manufacturing
With inlet isolation valve
- GC/MS
- Beam and particle physics
- Backing a turbo pump
- Quietest pump available
- Lowest vibration at inlet available
- Good speed to evacuate a large chamber
- Safegaurds your system and high vacuum pump in case of power loss
- Isolates the pump inlet during turbulent stop and start
- Hermetically sealed (magnetic torque coupling)
- Precise vacuum control
- Smart features- visibility and control
- Communications/Remote access and control (analog and digital)
- Inverter for universal voltage, flexible and easy
IDP-45
60 Hz
750 L/min
45 m³/h
60 Hz
1.07 × 10-² mbar
8 × 10-³ Torr
1.5 HP (1.1 KW)/
100-127; 200-240 VAC
Значения приведены дословно, как напечатано на странице; для IDP-45 колонки Common Applications и Advantages на странице пусты.
Engineering Facts
12 facts · every claim linked to a page
Maintenance
Tip seal or pumping module replacement is a DIY task needed only about every two to three years and takes roughly half an hour.
Sets realistic maintenance intervals and labor expectations for planning service and spare parts.
Source
“This can be performed approximately every two to three years and requires about half an hour.”
Installation
The pumps use standard IEC power cords that are not hard-wired, simplifying electrical integration.
Affects electrical cabinet design and allows easy cord replacement or regional plug changes.
Source
“Agilent IDP dry scroll pumps also use standard IEC power cords that are not hard-wired to the motor.”
Installation
Small footprint, low weight and minimal power requirements allow use inside cabinet enclosures without special voltage.
Confirms the pump can be enclosed and powered from standard utilities, easing system layout.
Source
“They place litte burden on utilities, require no special voltage, and are suitable for use inside cabinet enclosures.”
Safety
The optional integral isolation valve closes the inlet in about 20 ms on power loss to prevent backstreaming and sudden venting.
Critical for protecting the vacuum system and high-vacuum pump during power interruptions.
Source
“Upon power loss, the solenoid valve vents a small chamber beneath the valve, which closes the inlet valve (approximately 20 milliseconds).”
Operation
After power is restored, the inlet valve reopens in about 10–30 seconds once the pump evacuates.
Defines restart timing and sequencing for automated vacuum control logic.
Source
“Once power is restored, the solenoid closes, the pump evacuates, and the inlet valve opens (approximately 10-30 seconds).”
Operation
IDP-35 and IDP-45 have a tool-free adjustable gas ballast with Hi, Low, or No Flow settings for vapor handling.
Allows operators to optimize performance for water vapor or solvent loads without tools.
Source
“The IDP-35 and IDP-45 models come standard with a simple (no tools), user-adjustable gas ballast knob.”
Performance
The VFD provides consistent pumping performance from 105 VAC to 240 VAC at 50 or 60 Hz.
Enables one pump model to be used globally without voltage-specific variants.
Source
“Get consistent performance worldwide from 105 VAC to 240 VAC (50 Hz or 60 Hz).”
Installation
IDP-35 and IDP-45 offer RS-232, RS-485, or analog interfaces for PC or PLC integration.
Determines available communication options for remote monitoring and control.
Source
“The IDP-35 and IDP-45 dry scroll pumps can be used with RS-232 or RS-485 or with an analog interface.”
Operation
Rotational speed can be reduced after reaching vacuum to lower noise, energy consumption, and wear.
Supports energy-saving and noise-reduction operating strategies.
Source
“Decrease once vacuum pressure is reached to make the system even quieter and reduce energy consumption and wear.”
Selection
IDP-35 and IDP-45 can be fitted with an integrated Pirani gauge covering 1x10-4 to 1000 mbar.
Affects selection when in-built pressure monitoring is required without external gauges.
Source
“fitted with an integrated Pirani gauge head to measure pressures in the range of 1x10-4 to 1000 mbar”
Selection
IDP-35 and IDP-45 are hermetically sealed with magnetic torque coupling, suitable for rare gas and helium recirculation.
Important for applications requiring complete isolation of pumped gases from the environment.
Source
“Hermetically sealed (magnetic torque coupling)”
Selection
IDP-15 is described as the quietest pump available with the lowest vibration at inlet.
Guides selection where acoustic noise and vibration are critical constraints.