HiPace 800 P with TC 400 — product leaflet
Technical Reference Summary
Covered Models & Document Scope
Pfeiffer Vacuum HiPace 800 P turbomolecular vacuum pump — a high-performance pump designed for coating processes with an optimized rotor/stator concept. The document is a short brochure/datasheet (3 pages) covering technical data, accessories and options; no ordering codes are given.
Section-by-Section Technical Breakdown
Highlights the pump's positioning for coating applications: high performance, reliability and easy maintenance. Emphasizes hybrid bearing technology and on-site bearing change with tolerance to process dust.
- Specially designed for coating processes, optimized rotor/stator concept
- Best-in-class hybrid bearing technology, long life cycle, maximum uptime
- On-site bearing change, insensitive to process dust
Pumping speeds, compression ratios and gas throughputs for N₂, H₂, He and Ar, plus mechanical and operating data. Defines forevacuum limit, run-up time, noise level and weight.
- Pumping speed: N₂ 785 l/s, H₂ 320 l/s, He 595 l/s, Ar 770 l/s
- Compression ratio: N₂ 1·10⁶, H₂ 4·10², He 3·10³, Ar 1·10⁷
- Gas throughput at final rotational speed: N₂ 2.5 hPa·l/s, H₂ 8 hPa·l/s, He 5 hPa·l/s, Ar 2 hPa·l/s
- Max. forevacuum pressure for N₂: 1.1 hPa
- Run-up time: 1.6 min
- Sound pressure level (EN ISO 2151): 50 dBA
- Weight approx. 12.7 kg
- Communication interfaces standard: RS-485, remote
- Mounting orientation: arbitrary
- Gas inlet DN 200 ISO-K/ISO-F/CF-F; outlet DN 25 ISO-KF / G 1/4"
Lists available accessories and options for the HiPace 800 P, covering electrical, fieldbus, mounting, venting and vibration items.
- Electrical adapter, mains cable, connecting cable
- Various fieldbus systems
- Power supply kit and display unit
- Mounting kit, safety valve
- Venting accessories, power failure venting unit
- Vibration damper
Key Integration, Operating & Safety Requirements
| Specification / Condition | Engineering Implication | Applies To |
|---|---|---|
| Pumping speed for N₂ is 785 l/s at final rotational speed. p.2 ↗ | Size the forevacuum pump and process chamber conductance so effective speed near 785 l/s is preserved at the DN 200 inlet. | HiPace 800 P |
| Pumping speed for H₂ is 320 l/s, for He 595 l/s and for Ar 770 l/s. p.2 ↗ | For hydrogen-containing coating processes expect ~40% of N₂ speed; consider gas-type effects when estimating pump-down of light gases. | HiPace 800 P |
| Compression ratio for N₂ is 1·10⁶ and for Ar 1·10⁷. p.2 ↗ | Very high compression for heavy gases supports clean high-vacuum base pressures when backed adequately. | HiPace 800 P |
| Compression ratio for H₂ is only 4·10² (He: 3·10³). p.2 ↗ | Ultimate pressure for hydrogen is limited by forevacuum pressure; a low-H₂-content backing pump is needed for low total pressure with hydrogen. | HiPace 800 P |
| Maximum admissible forevacuum pressure for N₂ is 1.1 hPa. p.2 ↗ | Select and size the backing pump to maintain foreline pressure below 1.1 hPa at full gas throughput to avoid loss of compression/back-migration. | HiPace 800 P |
| Gas throughput at final speed is 2.5 hPa·l/s for N₂ and 8 hPa·l/s for H₂. p.2 ↗ | Check backing pump throughput against these values when specifying continuous gas loads in coating processes. | HiPace 800 P |
| Run-up time is 1.6 min to final rotational speed. p.2 ↗ | Allow ~2 minutes from start to full pumping performance in process automation timing; consider power failure venting unit if process cannot tolerate this delay after restart. | HiPace 800 P |
| Gas inlet flange is DN 200 ISO-K/ISO-F/CF-F; outlet is DN 25 ISO-KF or G 1/4". p.3 ↗ | Plan chamber interface with DN 200 hardware and select matching foreline connections; CF option available for UHV-tight systems. | HiPace 800 P |
| Mounting orientation is arbitrary. p.3 ↗ | The pump can be installed horizontally or vertically, simplifying integration into coating systems without orientation constraints. | HiPace 800 P |
| Standard communication interfaces are RS-485 and remote. p.3 ↗ | Plan control wiring for RS-485; additional fieldbus systems are available as options for higher-level control integration. | HiPace 800 P |
| Sound pressure level is 50 dBA per EN ISO 2151. p.2 ↗ | Suitable for installation in close proximity to operators without special acoustic enclosure. | HiPace 800 P |
| Weight is approximately 12.7 kg. p.2 ↗ | Single-person handling feasible; mounting brackets/supports must be sized for this mass plus attached cabling and vibration damper. | HiPace 800 P |
| Hybrid bearing technology allows on-site bearing change. p.1 ↗ | Maintenance can be performed in situ, reducing downtime versus returning the pump to the factory; schedule bearing replacement around process campaigns. | HiPace 800 P |
| The rotor/stator concept is insensitive to process dust and optimized for coating processes. p.1 ↗ | Suitable for sputtering/evaporation environments with particulate load without additional particle protection in many cases. | HiPace 800 P |
| A power failure venting unit and venting accessories are available as options. p.1 ↗ | Specify the power failure venting unit to automatically vent the pump on mains failure, protecting the process chamber from oil/backstreaming-related contamination paths. | HiPace 800 P |