Agilent Technologies 1260 Infinity II Multidetector GPC/SEC System

Agilent Technologies 1260 Infinity II Multidetector GPC/SEC System — Liquid chromatography.

The 1260 Infinity II Multidetector GPC/SEC System is a high-temperature gel-permeation chromatography platform built around a 220 °C column oven, a 40-vial autosampler with two heated zones, and a differential refractive index detector. It is the high-temperature modification of the 1260 Infinity II GPC/SEC series, distinguished from the ambient Bio-SEC siblings by its 230 VAC/50 Hz supply, 136 kg frame, and solvent-compatible oven. It is used to separate and characterize synthetic polymers by molecular weight in THF or TCB at temperatures up to 220 °C.

Agilent Technologies GPC SEC Solutions Series — Model Comparison & Selection

Model Pumping speed, m³/hSample volume, milliliterColumn particle size, µmColumn temperature, °CColumn inner diameter, mmColumn length, m
1260 Infinity II Multidetector GPC/SEC System Current —5...500—220——
1260 Infinity II Bio-SEC System 0.024—1.8—2.10.05
1260 Infinity II Bio-SEC system | Biological polymer analysis 4.8×10⁻⁵0.012.730——
1290 Infinity II GPC/SEC system 3.6×10⁻⁶0.023354.60.25

Full specifications

Core Performance & Functional Specifications
Wavelength range 890 nm
Column Pore Size 300 Å
Column temperature 220 °C
Precision 1 millimeter
Sample volume 5...500 µL
Column dimensions mfr 7.8 mm
Monomer content before sonication mfr 76.12
Dimer content before sonication mfr 16.45
Aggregates content before sonication mfr 7.44
Monomer content after sonication mfr 83.80
Dimer content after sonication mfr 12.25
Aggregates content after sonication mfr 3.95
Safety standards mfr IEC, CSA, UL UL
Flow Rate Reproducibility mfr 0.07 SD
Column Capacity mfr 6 columns
Cell Volume mfr 8 μL
Carousel Capacity mfr 40 vials
Deflection mfr Differential Refractometer Refractometer
Instrument Control mfr Microprocessor Microprocessor
Flow Rate Reproducibility1 mfr 0.07 temperature
Detector Differential Refractometer Deflection Cell Volume mfr 8 μL
Noise2 mfr 100 μV
Drift2 mfr 10 mV/h
Autosampler Carousel Capacity mfr 40 Vials
Precision1 mfr 1
DMSO mfr 215
Dibutoxymethane mfr 220
Tetrahydrofuran mfr 321
Dimethylformamide mfr 445
Toluene mfr 480
Acetone mfr 465
m-Cresol mfr 558
Chloronaphthalene mfr 558
DRI cell volume mfr 8 μL
Carousel capacity mfr 40 Vials
Syringe sample volume mfr 800 μL
DRI reference purge time mfr 20 min
Solvent filter pore size mfr 0.45 μm
Dimensions, Weight & Mechanical Design
Weight 136 kg
Model protein monomer mass mfr 150 kDa
Model protein dimer mass mfr 300 kDa
Size (width × depth × height) mfr 900 mm
Packaged Size (width × depth × height) mfr 930 mm
Bench width mfr 90 cm
Bench depth mfr 53 cm
Bench height mfr 62 cm
Oven open height mfr 97 cm
Electrical, Power & Drive Specifications
Line voltage mfr 230 VAC
Line frequency mfr 50 Hz
Power consumption mfr 3300 BTU
Interfaces, Connections & Control
Instrument Interface mfr 7 bit
Operating Conditions, Environment & Protection
Noise 100 µV
Operating Altitude 2000 m
Non-operating altitude mfr 4600 m
Humidity mfr 25...30 °C
Standards, Safety & General Data
Safety standards: IEC, CSA, UL mfr 2

Description

Construction and positioning

Behavior under load and in different modes

Installation, connection and control

Integration & Operating Notes

Electrical
Dedicated 230 VAC circuit with RCCB is mandatory

The system draws 3300 VA (2310 W) at 230 VAC ±10%, 50 or 60 Hz ±5%, and has no voltage selector. A shared or undersized circuit will trip or cause unstable detector baselines; provide a dedicated single-phase supply with earth leakage protection.

User Manual, Physical Specifications, page 24
Mounting
Bench must support 136 kg and allow four-person lift

At 136 kg (300 lbs.), the instrument requires at least four persons or lifting equipment to place it. Use a sturdy bench of at least 90 cm width, preferably with wheels, and plan the final location before unpacking to avoid moving the unit after installation.

User Manual, Unpacking the Main Module, page 29
Cooling & Media
Exhaust airflow must stay below 1.0 SLM

The four-inch fan-forced exhausts must be connected to fume extraction or a hood with airflow <1.0 SLM. Higher extraction rates can cool the oven unevenly and disturb the RI baseline; verify the extraction balance before running temperature-sensitive methods.

User Manual, Site Requirements, page 23
Control & I/O
Pump must be powered before the HT GPC system

Turning on the G7110B pump first ensures it is initialized and ready before the HT GPC system starts communication. Reversing the order can cause communication errors and require a full restart of the system and PC.

User Manual, Installing the System, page 34
Process Limits
Oven heat rate limited to 1 °C/min below 100 °C

Programmable heat rate is 0.4–2 °C/min, but setpoints below 100 °C must use ≤1 °C/min to prevent overshoot and prolonged stabilization. Above 100 °C, 1 °C/min is recommended; faster rates risk tripping the over-temperature cut-out set about 5 °C above operating temperature.

User Manual, Oven Configuration Editor, pages 42–43
Maintenance
Allow 8 hours for RI baseline equilibration

After a temperature change or solvent switch, the system typically needs 8 hours to reach a stable RI baseline. Plan equilibration overnight before analysis; automatic RI conditioning can then purge and autozero until drift falls within the configured RI limits.

User Manual, General Troubleshooting Guide, page 75
Maintenance
Keep position 0 vial empty with a clean cap

The autosampler zero position is an index/waste vial and must remain empty with a clean, shiny cap. A blocked or contaminated zero vial can cause polymer precipitation and injection errors; inspect and replace the cap as part of routine maintenance.

User Manual, System Description and General Operation, page 14

Selection & Integration Q&A

When should I choose this Multidetector GPC/SEC System instead of the Bio-SEC or standard GPC/SEC siblings?

Choose this model for high-temperature GPC/SEC in THF or TCB up to 220 °C with up to six 30 cm columns. The Bio-SEC siblings are for ambient biological mobile phases; the standard 1260 Infinity II GPC/SEC lacks the 220 °C oven and heated autosampler zones.

What power and exhaust provisions must be in place before the system is installed?

Provide a dedicated 230 VAC ±10% single-phase circuit with earth and RCCB, 50 or 60 Hz ±5%, rated for 3300 VA. Route the four-inch fan-forced exhausts to fume extraction with airflow <1.0 SLM. No voltage selector is present, so the supply must match the nameplate.

What ambient and duty-cycle limits apply to the installation site?

Operate at 15–30 °C ambient and 25–30% humidity, at altitudes up to 2000 m. Non-operating range is -40 to 70 °C and 4600 m. If shipped cold, let the box warm to room temperature and wait 1 h after unpacking before applying power to avoid condensation damage.

What maintenance and consumables are required beyond the base delivery?

Plan for 8 h RI baseline equilibration after temperature changes, periodic autozero/purge cycles (0–38 cycles, purge 0–3600 s), and replacement of the zero-position vial cap. The base delivery excludes the G7821B viscometer and G7822B dual-angle light scattering detectors, which are optional add-ons.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent 1260 Infinity II High Temperature GPC System User Manual
Manual ·142 pp.