Agilent Technologies 1260 Infinity III LC System
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 1260 Infinity III LC System

Agilent Technologies 1260 Infinity III LC System — Liquid chromatography with Flow rate 0.6 liter/minute, Pumping speed 6×10⁻⁵ m³/h.

The Agilent 1260 Infinity II GPC/SEC System is a quaternary HPLC configuration built around the G7111B pump, G7129A vialsampler with integrated G7130A column compartment, and G7114B variable wavelength detector. It operates at 1.0 mL/min with a 100 µL analytical head and 100 µL injection loop, supporting up to 600 bar and 80 °C column temperature. This modification targets size-exclusion separations requiring stable flow and precise injection volumes.

Flow rate
0.6 liter/minute
Pumping speed
6×10⁻⁵ m³/h

Agilent Technologies Analytical HPLC Systems Series — Model Comparison & Selection

Model Flow rate, liter/minuteSample volume, milliliterColumn temperature, °CData rate, HzOperating altitude, mWeight, kg
1260 Infinity III LC System Current 0.60.00540120——
1220 Infinity II LC System —15080200030
1260 Infinity III Prime LC System 9×10⁻⁴0.0024040300011.5

Full specifications

Core Performance & Functional Specifications
Detection limit 0.068 pmol/µL
Flow rate 0.600 mL/min
Pumping speed 1.0 mL/min
Analytical Head Volume 100 µL
Baseline Drift 10...4 AU/h
Column Particle Size 2.7 µm
Column temperature 40 °C
Data Rate 120 Hz
Detection wavelength 254 nm
Flow Cell Volume 14 µL
Flow Rate (1220 Infinity Ii Lc) 10 mL/minute
Flow Rate (1290 Infinity Iii Lc) 5 mL/minute
Flow Rate Range 5 mL/min
Injection Loop Volume 100 µL
Maximum operating pressure 600 bar
Peak Area Rsd 0.20 %
Post Time 1 min
Retention Time %rsd 0.02 %
Sample Loop Volume 100 µL
Sample volume 5 µL
Metering device volume mfr 100 μL
Stop time mfr 15 min
FLD cell volume mfr 8 μL
Software version mfr 2.8 later
Calibration range mfr 2.25...90 pmol/μL
Calibration R2 mfr 0.99999
Binary Pump mfr High-Speed Pump*
Quaternary Pump mfr Flexible Pump**
Solvent Preparation mfr 1260 Degasser
Solvent Delivery mfr 1260 Pump
Valve Solutions mfr InfinityLab Quick Change Valves Valves
Maximum operating pressure (1290 Infinity III LC) mfr 1300 bar
Maximum operating pressure (1260 Infinity III Prime LC) mfr 800 bar
Maximum operating pressure (1260 Infinity III LC) mfr 400 bar
Pressure at 2 mL/min (1290 High-Speed Pump) mfr 1300 bar
Pressure at 5 mL/min (1290 High-Speed Pump) mfr 800 bar
Pressure (1260 Infinity III Flexible Pump) mfr 800 bar
Pressure (1260 Infinity III Binary Pump) mfr 600 bar
Pressure (1260 Infinity III Quaternary Pump VL) mfr 400 bar
Flow rate (1260 Infinity III Quaternary Pump VL) mfr 10 ml/min
Sample capacity (1290 Infinity III Multisampler) mfr 6144 samples
Carryover (1290 Infinity III Multisampler multiwash) mfr 9 ppm
Wavelength range (1290 Infinity III DAD) mfr 190...640 nm
Wavelength range (1260 Infinity III DAD WR) mfr 190...950 nm
ELSD flow range (1290 Infinity III ELSD) mfr 0.2...5 mL/min
RI measurement range (1290 Infinity III RID) mfr 600 RIU
Solvent mfr 10 Methanol/Water
Agilent 1260 Infinity II Multisampler mfr 28.3784
Agilent 1260 Infinity II Vialsampler mfr 28.5657
Dimensions, Weight & Mechanical Design
Column Inner Diameter 2.1 mm
Column Length 50 mm
Detector Flow Cell Path Length 10 mm
Flow Cell Path Length 10 mm
Operating Conditions, Environment & Protection
Column Compartment Temperature 80 °C
Detector noise mfr 2.5 μAU
Column thermostat range (1290 Infinity III Multicolumn thermostat) mfr 20...110 °C
Column thermostat range (1260 Infinity III Multicolumn thermostat) mfr 10...85 °C

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection, and control

Integration & Operating Notes

Process Limits
Do not exceed 600 bar system pressure

The quaternary pump and flow path are rated to a maximum operating pressure of 600 bar. Operating above this limit risks seal damage and invalid retention data; method development should keep backpressure below this threshold, especially with narrow-bore columns and high-viscosity GPC solvents.

Factory Specification Sheet
Control & I/O
OpenLab CDS 2.8 or later required for injector programs

Automated sample preparation workflows using injector programs require OpenLab CDS version 2.8 or later. Earlier software versions will not execute the injection sequences described in the technical overview, so the data system must be upgraded before commissioning these methods.

Technical Overview, Injector Program Sample Preparation, 5994-7703EN
Cooling & Media
Sample cooler holds samples at 4 °C

The sample cooler is set to 4 °C to preserve thermally labile polymer solutions during extended GPC/SEC runs. Ensure the cooler is operational before loading samples; condensation management and solvent compatibility at low temperature should be verified for the mobile phase in use.

Factory Specification Sheet
Maintenance
Replace metering device and loop as a set for volume accuracy

The 100 µL metering device and 100 µL sample loop are matched components; replacing one without the other can shift injection volume accuracy. During scheduled maintenance, verify both volumes and recalibrate the injector using the OpenLab CDS injector calibration routine.

Technical Overview, 1260 Infinity II LC, 5994-2174EN

Selection & Integration Q&A

When should I choose the 1260 Infinity II GPC/SEC System over the 1220 Infinity II LC or the 1260 analytical-scale purification system?

Choose this GPC/SEC configuration when you need a quaternary pump with 100 µL injection loop and integrated column compartment for size-exclusion separations up to 600 bar and 80 °C. The 1220 Infinity II LC is a compact isocratic system for routine HPLC, while the 1260 analytical-scale purification system is optimized for fraction collection, not GPC/SEC.

What detector and column hardware must be mated to this system for GPC/SEC operation?

The system includes the G7114B VWD with a 10 mm path, 14 µL flow cell; GPC/SEC columns with 2.1 mm internal diameter and 2.7 µm particles are supported. Ensure column end-fittings match the low-dead-volume connections of the G7130A column compartment, and use the FLD cell (8 µL) only if fluorescence detection is added.

What maintenance items and accessories are not included in the base delivery?

The base system includes the pump, vialsampler, column compartment, and VWD, but not GPC/SEC columns, guard columns, or solvent filtration kits. OpenLab CDS 2.8 software is required and may be licensed separately. Replacement metering devices (100 µL) and sample loops are consumables; schedule seal and loop replacement per the pump maintenance interval.