Agilent Technologies 4150 TapeStationDx
Agilent Technologies 4150 TapeStationDx — Automated electrophoresis.
The 4150 TapeStationDx is a CE-IVD-labeled automated electrophoresis instrument for DNA/RNA sample QC in regulated laboratories. It processes 1–96 samples per run with a 2 µL sample input and a 90-minute run time for 96 samples, using an 8-well strip loading format. It is the lower-throughput sibling of the 4200 TapeStationDx, which is described as the high-throughput variant.
Agilent Technologies Tapestation Instruments Series — Model Comparison & Selection
| Model | Sensitivity | Dimensions w d h | Weight, kg | Storage temperature, °C | Analysis time, min | Application |
|---|---|---|---|---|---|---|
| 4150 TapeStationDx Current | — | — | — | — | — | automated electrophoresi |
| 4150 TapeStation | 5 | 254 | 17.8 | -40...70 | 16 | — |
| 4200 TapeStation | 5 | 435 | 25.5 | -40...70 | 16 | — |
| 4200 TapeStationDx System | — | — | — | — | — | automated electrophoresi |
Full specifications
| Application | automated electrophoresis for QC of DNA and RNA samples isolated from human specimen |
| Run Time For 96 Samples | 90 minutes |
| Sample Capacity | 1...96 samples |
| Sample Input Volume | 2 µL |
| Time per sample mfr | 1...2 minutes |
| Samples per run mfr | 1...96 samples |
| Sample loading format mfr | 8 plate |
| Analysis time per sample mfr | 1...2 minutes |
| Instrument format mfr | compact benchtop benchtop |
| Regulatory labeling mfr | CE-IVD IVD |
| Compliance support mfr | 21 frameworks |
| throughput (4200) mfr | 1...96 samples |
| throughput (4150) mfr | 1...16 samples |
| time per sample mfr | 1...2 minutes |
Description
Series positioning
- The 4150 TapeStationDx belongs to the Agilent TapeStationDx portfolio alongside the 4200 TapeStationDx; the 4200 is described as the high-throughput variant supporting 1–96 samples.
- The 4150 TapeStationDx is the CE-IVD-labeled configuration intended for DNA/RNA sample QC in clinical and regulated laboratories.
- Sibling non-Dx models (4150 TapeStation, 4200 TapeStation) are listed with a 5 ng/µL sensitivity figure; no sensitivity value is stated for the Dx model in the verified facts, so none is asserted here.
Throughput and run behavior
- Samples per run: 1–96; time per sample: 1–2 minutes; run time for 96 samples: 90 minutes.
- Sample input volume: 2 µL per sample.
- Sample loading format is given as an 8-well strip format.
- No digitized curve points were supplied, so no migration/sizing performance curves are described.
Documentation scope
- The attached portfolio document covers both the 4150 and 4200 TapeStationDx systems; it contains no extracted section-level engineering facts, so installation, control and connection specifics are not detailed in the verified material.
Integration & Operating Notes
Each sample consumes 2 µL, and a run can carry between 1 and 96 samples. Batching below full capacity is permitted, but the 90-minute figure applies to a 96-sample run; smaller batches should be scheduled against the 1–2 minute per-sample figure rather than the full-plate time.
The verified loading format is an 8-well strip. Labs planning 96-sample runs must account for arranging samples across multiple 8-well strips rather than a single plate, which affects consumable planning and bench workflow.
The TapeStationDx portfolio document describes the Dx systems as CE-IVD-labeled for DNA/RNA sample QC in clinical and regulated laboratories. Confirm the applicable regulatory status for your jurisdiction before placing the instrument in a diagnostic workflow.
Selection & Integration Q&A
Choose the 4150 TapeStationDx when you need CE-IVD-labeled DNA/RNA sample QC in a regulated or clinical lab at moderate throughput. The 4200 TapeStationDx is described as the high-throughput variant; the non-Dx 4150 TapeStation is listed separately with a 5 ng/µL sensitivity figure.
Upstream steps must deliver 2 µL per sample, and downstream analysis should be planned around batches of 1–96 samples. A full 96-sample run takes 90 minutes, so adjacent steps should be scheduled against that window rather than per-sample timing alone.
Runs accept 1–96 samples with 1–2 minutes per sample and 90 minutes for a full 96-sample run. Samples are loaded in an 8-well strip format, so a 96-sample batch requires multiple strips; plan strip handling and bench space accordingly.
The verified facts contain no maintenance schedule, service interval, error-code list, or accessory/cable/consumable delivery list for the 4150 TapeStationDx. These must be obtained from the full instrument manual or Agilent before planning service and consumable procurement.