No photo available yet
Agilent Technologies 4200 TapeStationDx System
Agilent Technologies 4200 TapeStationDx System — Automated electrophoresis.
The 4200 TapeStationDx System is a CE-IVD-labeled automated electrophoresis instrument for DNA/RNA sample QC in regulated laboratories. It is the high-throughput variant of the TapeStationDx series, processing 1–96 samples per run with a 2 µL sample input and a 90-minute run time for 96 samples. It is used for quality control of nucleic acid samples prior to downstream analytical or clinical workflows.
Agilent Technologies Tapestation Instruments Series — Model Comparison & Selection
| Model | Sensitivity | Dimensions w d h | Weight, kg | Storage temperature, °C | Analysis time, min | Application |
|---|---|---|---|---|---|---|
| 4200 TapeStationDx System Current | — | — | — | — | — | automated electrophoresi |
| 4150 TapeStation | 5 | 254 | 17.8 | -40...70 | 16 | — |
| 4150 TapeStationDx | — | — | — | — | — | automated electrophoresi |
| 4200 TapeStation | 5 | 435 | 25.5 | -40...70 | 16 | — |
Full specifications
| Application | automated electrophoresis for QC of DNA and RNA samples isolated from human specimen |
| Run Time For 96 Samples | 90 minutes |
| Sample Capacity | 1...96 samples |
| Sample Input Volume | 2 µL |
| Time per sample mfr | 1...2 minutes |
| Samples per run mfr | 1...96 samples |
| Sample loading format mfr | 8 plate |
| Analysis time per sample mfr | 1...2 minutes |
| Instrument format mfr | compact benchtop benchtop |
| Regulatory labeling mfr | CE-IVD IVD |
| Compliance support mfr | 21 frameworks |
| throughput (4200) mfr | 1...96 samples |
| throughput (4150) mfr | 1...16 samples |
| time per sample mfr | 1...2 minutes |
Description
Construction and positioning
- The 4200 TapeStationDx is an automated electrophoresis system in the Tapestation Instruments series, distinguished from the 4150 TapeStationDx by its high-throughput capability: it supports 1–96 samples per run, whereas the 4150 is limited to lower throughput.
- The system is CE-IVD-labeled, intended for clinical and regulated laboratory environments.
- Sample loading is performed in an 8-well plate format (likely an 8-tube strip or 8-well column), enabling batch processing.
Behavior and performance
- Run time for a full 96-sample plate is 90 minutes, corresponding to approximately 1–2 minutes per sample.
- Sample input volume is 2 µL per sample, minimizing consumption of precious samples.
- No digitized curve points or additional performance data are available in the provided facts.
Installation and operation
- The document digest does not provide specific installation, connection, or control details. The system is operated as a standalone instrument with associated software (TapeStation Software), but no further operational specifics are available.
Selection & Integration Q&A
Choose the 4200 TapeStationDx when high-throughput sample QC is needed: it processes 1–96 samples per run with a 90-minute run time for 96 samples. The 4150 TapeStationDx is better suited for lower-throughput laboratories with fewer samples per batch.
The provided facts do not specify environmental operating conditions or duty-cycle limits. Refer to the instrument manual for details on operating temperature, humidity, and recommended run intervals.
Maintenance schedules and consumables are not detailed in the provided facts. The base delivery likely does not include consumables such as tapes, reagents, or plates; these must be ordered separately. Consult the manual for service intervals.