No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Take gene expression to the next level, Custom Exon Microarrays

Agilent Technologies Take gene expression to the next level, Custom Exon Microarrays — Gene expression microarray platform.

Custom Exon Microarrays are a one-color or two-color 60-mer oligonucleotide array platform for exon-level expression profiling from 25–100 ng total RNA using Low Input Quick Amp WT labeling. This custom modification differs from the series' gene-expression and yeast arrays by exon-level probe content and a defined spike-mix workflow. It serves transcriptome-wide exon analysis in a microarray hybridization system.

Agilent Technologies Custom Microarrays Series — Model Comparison & Selection

Model Total rna input, ngTotal rna input highest listed, ngTotal rna input lowest listed, ngCdna synthesis incubation, °CCdna synthesis incubation time, hoursCrna elution volume, microliter
Take gene expression to the next level, Custom Exon Microarrays Current 251002540230
Custom Gene Expression Microarray 10...2002001040230

Full specifications

Core Performance & Functional Specifications
Cdna Synthesis Incubation Time 2 hours
Crna Elution Volume 30 µL
Crna Transcription Incubation Time 2 hours
Enzyme Inactivation Time 15 minutes
Fragmentation Incubation Time 30 minutes
Hybridization Duration 17 hours
Hybridization Rotator Speed 10 rpm
Hybridization Time 17 hours
Hybridization Volume 490 µL
Maximum Total Rna Sample Volume 2.3 µL
Minimum Pipette Dispensing Volume 2 µL
Pipetting volume 2 µL
Primer/template Denaturation Time 10 minutes
Recommended Crna Yield 5 µg
Spike Mix Heat Incubation Time 5 minutes
Spike Mix Volume Per Labeling Reaction 2 µL
Starting Total Rna Amount 25 ng
Step 1 Time Required 0.5 hours
Total Rna Input 25 ng
Total Rna Input, Highest Listed 100 ng
Total Rna Input, Lowest Listed 25 ng
Total Volume 3
Triton X-102 Final Concentration In Wash Buffers 0.005 %
Minimum Feature Extraction software version for automatic eArray download mfr 10.7
Spike A Mix labeling dye mfr 3
Feature Extraction Software version for SpikeIns LogRatio Statistics mfr 10.7.3 later
Feature Extraction software version mfr 10.7 higher
Specific activity mfr 15 cRNA
Recommended specific activity mfr 15 cRNA
Agilent Microarray Scanner mfr 4900 BA
Hybridization gasket slides 1 microarray/slide, 5 slides/box mfr 2534
Hybridization gasket slides 2 microarrays/slide, 5 slides/box mfr 2534
Hybridization gasket slides 4 microarrays/slide, 5 slides/box mfr 2534
Hybridization gasket slides 8 microarrays/slide, 5 slides/box mfr 2534
G4832A mfr 3 Kit
G4857A-028679 mfr 3 Microarray
G4848A mfr 3 Kit
G4856A-028680 mfr 3 Microarray
RNA 6000 Nano Assay Kit (RNA Series II Kit) mfr 5067
Stabilization and Drying Solution* mfr 5185
Ozone-Barrier Slide Cover* mfr 2505
Absolutely RNA Nanoprep Kit mfr 400753
slide box mfr 07201629
acetonitrile mfr 271004 L
sulfolane mfr 22209
thermal cycler mfr 96 tubes
Hybridization oven rotator for Agilent Microarray Hybridization Chambers mfr 2530
nuclease-free 1.5 mL microfuge tube mfr 12400 equivalent
magnetic stir bar (×2) mfr 401435 equivalent
magnetic stir plate (×2) mfr 6795 equivalent
circulating water baths or heat blocks set to 37°C, 40°C, 60°C, 65°C, 70°C, and 80°C mfr 6795 equivalent
microcentrifuge mfr 5417 equivalent
sterile storage bottle mfr 455 equivalent
spectrophotometer mfr -1000 equivalent
micropipettor mfr -10 equivalent
slide-staining dish, with slide rack (×3) mfr 121 equivalent
vacuum concentrator mfr 120 equivalent
RNA 6000 Nano LabChip Kit mfr 5067
RNA 6000 Pico LabChip Kit mfr 5067
Spectrophotometer mfr -1000 equivalent
Universal Human Reference RNA mfr 740000
Universal Mouse Reference RNA mfr 740100
Universal Rat Reference RNA mfr 740200
Low Input Quick Amp WT Labeling Kit, One-Color mfr 5190
RNA Spike-In Kit, One-Color mfr 5188
Gene Expression Hybridization Kit mfr 5188
Gene Expression Wash Buffer Kit mfr 5188
DNase/RNase-free distilled water mfr 10977
RNeasy Mini Kit mfr 74104
ethanol (95% to 100% molecular biology grade) mfr 7023 ML
Affinity Script RNase Block Mix (violet cap) mfr 1.2
Recommended total RNA input (2-, 4-, 8-pack) mfr 50 ng
Prewarm duration for 5× First Strand Buffer mfr 3...4 minutes
Triton X-102 (10%) volume added to wash buffer cubitainer mfr 2 mL
Wash 2 duration mfr 1 minute
Wash 1 duration mfr 1 minute
Thermocycler Program 1 initial denaturation duration mfr 10 minutes
Thermocycler Program 2 incubation duration mfr 2 hours
Thermocycler Program 2 inactivation duration mfr 15 minutes
Labeled cRNA expected size range lower bound mfr 200 nucleotides
Low Input Quick Amp WT Labeling Kit, Two-Color mfr 5190
RNA Spike-In Kit, Two-Color mfr 5188
minimum labeled cRNA per microarray mfr 1.65 μg
ozone robustness level mfr 5 ppb
thermocycler program 1 time mfr 10 minutes
thermocycler program 2 time mfr 2 hours
thermocycler program 2 second time mfr 15 minutes
thermocycler hold time mfr 5 minutes
cRNA size range lower bound mfr 200 nucleotides
Electrical, Power & Drive Specifications
Hybridization Chamber, stainless mfr 2534 A
Interfaces, Connections & Control
Spike A Mix serial dilution (first) mfr 1
Spike A Mix serial dilution (second) mfr 1
Spike A Mix serial dilution (third) mfr 1
Spike A Mix serial dilution (fourth) mfr 1
Serial dilution first mfr 1
Serial dilution second mfr 1
Serial dilution third mfr 1
Serial dilution fourth mfr 1
Operating Conditions, Environment & Protection
Cdna Synthesis Incubation 40 °C
Crna Transcription Incubation Temperature 40 °C
Enzyme Inactivation Temperature 70 °C
First Strand Buffer Prewarm Temperature 80 °C
Fragmentation Incubation 60 °C
Hybridization Temperature 65 °C
Spike Mix Heat Incubation Temperature 37 °C
Spike Mix Heating Temperature 37 °C
Storage Temperature Of 10× Blocking Agent -20 °C
Storage Temperature Of Total Rna >100 Ng/µl -80 °C
T7 Primer Denaturation Temperature 65 °C
Wash Buffer 2 Prewarm Temperature 37 °C

Description

Construction and series positioning

Working range and sample behavior

Data extraction and control

Integration & Operating Notes

Control & I/O
Feature Extraction 10.7+ required for automatic eArray download

Automatic eArray download during data extraction requires Feature Extraction software version 10.7 or higher. SpikeIns LogRatio Statistics require version 10.7.3 or later; running an older build blocks these outputs.

G4140-90042 Exon One color 2.0, Step 2 Extract data

Selection & Integration Q&A

When should I choose the custom exon microarray rather than the custom gene-expression or yeast array in the same series?

Pick the exon array when the experiment requires exon-level resolution across a custom probe set. Choose the custom gene-expression array for gene-level custom content, or the yeast array for yeast transcriptome work; probe content, not hardware, is the differentiator.

What software and labeling workflow must be in place around this array for data to be usable?

Feature Extraction 10.7 or higher is needed for automatic eArray download, and 10.7.3+ for SpikeIns LogRatio Statistics. Labeling follows Low Input Quick Amp WT with 25–100 ng total RNA and 2 µL Spike Mix per reaction.

Which reagents and consumables are not included with the array and must be procured separately?

The array delivery covers the microarray and protocol only. Low Input Quick Amp WT labeling reagents, Spike A/B Mix components, hybridization and wash buffers are separate consumables required to complete the one- or two-color workflow.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent One-Color Microarray-Based Exon Analysis (Low Input Quick Amp WT Labeling) Protocol
Manual ·1,5 МБ ·84 pp.
View PDF
PDF
Agilent Two-Color Microarray-Based Gene Expression Analysis (Low Input Quick Amp Labeling) Protocol
Manual ·1,5 МБ ·82 pp.
View PDF