Agilent Technologies Fluorescence Spectroscopy Instrumentation, Spectrofluorometers
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Fluorescence Spectroscopy Instrumentation, Spectrofluorometers

Agilent Technologies Fluorescence Spectroscopy Instrumentation, Spectrofluorometers — Molecular spectroscopy.

The Cary Eclipse is a benchtop fluorescence spectrophotometer using a xenon flash lamp and a red-sensitive photomultiplier extended to 900 nm. It supports fluorescence, phosphorescence, chemiluminescence and bioluminescence modes, with kinetics data collection at 80 points/s and scan speeds to 24000 nm/min. It is positioned for life-science and analytical labs needing sensitive, fast spectral acquisition.

Agilent Technologies Molecular Spectroscopy Series — Model Comparison & Selection

Model Wavelength rangeSample volume, milliliterAbsorbance error, %Atr path length, µmAtr surface diameter, mmCertified absorbance value of filter
Fluorescence Spectroscopy Instrumentation, Spectrofluorometers Current 900—————
FTIR Spectroscopy Equipment 5100...6000.02—2.62.5—
LDIR Chemical Imaging, IR & Imaging Spectroscopy ——————
UV-Vis & UV-Vis-NIR Spectroscopy, Cary Instruments ——0.189——0.369

Full specifications

Core Performance & Functional Specifications
Wavelength range 900 nm
Cuvette Volume 5 µL
Kinetics Data Collection Rate 80 points/s
Minimum Reduced-volume Cuvette Volume 5 µL
Red-sensitive Photomultiplier Sensitivity Extension 900 nm
Scan speed 24000 nm/min
Typical Lamp Life 10 years
Wavelength range scan time mfr 3 s
Xenon flash lamp lifetime mfr 3 flashes
Wavelength scan time (full range) mfr 3 s
Lamp type mfr xenon flash lamp lamp
Lamp lifetime mfr 3 flashes
Detection sensitivity mfr picoMolar amounts of fluorescein fluorescein
microplate reader conversion time mfr 30 seconds
96-well measurement time mfr 50 seconds
384-well measurement time mfr 90 seconds
image spot size mfr 2 mm
polarizer excitation limit mfr 275 nm
Dimensions, Weight & Mechanical Design
Bench footprint mfr 600 mm
Bench space (footprint) mfr 600 mm
bench footprint mfr 600 mm

Description

Construction and positioning

Behavior and modes

Installation and operation

Integration & Operating Notes

Process Limits
Confirm cuvette volume before committing to 5 µL assays

The 5 µL figure applies to the minimum reduced-volume cuvette; standard cuvettes and larger volumes require separate verification. Below the stated minimum, path length and signal-to-noise degrade, so assay volumes must be validated against the actual cell used.

Factory Specification Sheet
Maintenance
Lamp life figures conflict; verify before scheduling replacement

The specification lists a typical lamp life of 10 years and, separately, a xenon flash lamp lifetime of 3 flashes. These cannot both describe the same lamp. Obtain the correct replacement interval and part number from Agilent service documentation before setting a preventive-maintenance schedule.

Factory Specification Sheet
Control & I/O
Kinetics rate of 80 points/s sets minimum time resolution

At 80 points/s, the shortest resolvable interval between kinetics data points is 12.5 ms. Reactions faster than this cannot be resolved without changing acquisition settings, so assay design must match the chemistry to this sampling limit.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose this fluorescence spectrophotometer instead of the FTIR, Raman or UV-Vis siblings?

Choose this model for fluorescence, phosphorescence, chemiluminescence or bioluminescence work needing 900 nm red-sensitive detection and 80 points/s kinetics. FTIR, Raman and UV-Vis/UV-Vis-NIR are separate instrument families for absorption, vibrational or imaging measurements, not interchangeable configurations.

What adjacent equipment and interfaces must be confirmed before integrating this instrument?

The available brochure digest lists no electrical ratings, interface protocols or controller requirements. Confirm power, data interface and control software from the full instruction manual before specifying a PC, autosampler or LIMS connection; do not assume standard ports.

What duty-cycle and environmental limits apply to this instrument?

The supplied documents contain no operating temperature, humidity or duty-cycle data. The xenon flash lamp is pulsed rather than continuous, but flash rate and thermal limits are not stated. Obtain environmental specifications from Agilent before placing the unit in a non-climate-controlled lab.

What maintenance and consumables are required, and what is not included in base delivery?

Lamp replacement interval is unresolved: the sheet states both 10 years typical and 3 flashes. Cuvettes, reduced-volume cells and any control computer are not described as included. Confirm lamp part number, cuvette options and software licensing with Agilent before purchase.