Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Benchtop FTIR Instruments

Agilent Technologies Benchtop FTIR Instruments — Molecular spectroscopy.

The Agilent 4200 FlexScan is a handheld FTIR spectrometer for onsite molecular analysis, covering 5100–600 cm⁻¹ with a single-reflection ATR interface (2.6 µm effective pathlength, 2.5 mm surface). Its 3.8 kg weight and 20 cm bench footprint distinguish it from benchtop siblings in the series. It is used for rapid, non-destructive identification of liquids and solids directly in the field.

Agilent Technologies FTIR Spectroscopy Series — Model Comparison & Selection

Model Wavelength rangeSample volume, milliliterAtr path length, µmAtr surface diameter, mmEffective pathlength, µmOptical aperture, mm
Benchtop FTIR Instruments Current 5100...6000.022.62.52.625
Compact & Portable FTIR Systems, Mobile FTIR 5100...6000.022.62.52.625
FTIR Microscopes & Imaging Systems 5100...6000.022.62.52.625

Full specifications

Core Performance & Functional Specifications
Wavelength range 5100...600
Atr Surface Diameter 2.5 mm
Effective Pathlength 2.6 μm
Optical Aperture 25 mm
Sample volume 20 µL
Bench space required mfr 20 cm
ATR spectral range mfr 5100...600
Spectrometer Body mfr Glass-fiber reinforced polyamide for durability
Detector mfr High-sensitivity thermoelectrically cooled deute
Interferometer mfr 45 aperture
Bench space mfr 20 cm
Spectral range (KBr optics) mfr 7000...350
Spectral range (ZnSe optics) mfr 5100...600
DialPath path lengths mfr 30...1,000 microns
DialPath Modules mfr 5100...600
Sample Type mfr Lower-concentration components, more dilute solu
ZnSe engine spectral range mfr 5100...600
KBr engine spectral range mfr 7000...350
DialPath pathlength repeatability mfr 0.25 μm
DialPath custom pathlength mfr 1000 μm
TumblIR fixed pathlength range mfr 100 μm
Dimensions, Weight & Mechanical Design
Atr Path Length 2.6 μm
Weight 3.8 kg
Weight range 3.5 kg
ATR effective path length mfr 36.5
Footprint mfr 26.4 module
Materials, Media & Process Compatibility
ATR effective pH range mfr 1...14
ATR pH range mfr 5...9
ZnSe ATR pH range mfr 5...9

Description

Construction and series positioning

The 4200 FlexScan is the handheld FTIR variant in Agilent's onsite-analysis line, weighing 3.8 kg and requiring 20 cm of bench space when docked. Within the series, the 4300 handheld, 4500 portable, and 5500 compact models occupy adjacent positions; the 4200 is the base handheld configuration with a fixed single-reflection ATR interface. Unlike the benchtop Cary 635, which accepts interchangeable ZnSe, Ge, diamond, DialPath, TumblIR, and reflectance modules, the 4200's sampling interface is integral and not user-swappable.

Optical and sampling behavior

The spectrometer covers 5100–600 cm⁻¹. The ATR element provides a 2.6 µm effective pathlength and a 2.5 mm surface diameter, with a 25 mm optical aperture and a 20 µL sample volume. The ATR is rated for pH 5–9; strongly acidic or alkaline samples outside this window will attack the crystal. No digitized curve points were supplied, so spectral resolution and scan-speed behavior cannot be stated.

Installation and operation

No electrical, interface, or control specifications were provided in the verified facts, and the attached document digests contain no actionable engineering facts. Installation, power, and connectivity requirements must therefore be taken from the instrument's own manual rather than inferred here.

Integration & Operating Notes

Process Limits
Keep sample pH within 5–9 to protect the ATR crystal

The ATR element is rated for pH 5–9. Samples outside this range, including strong acids and bases, can corrode or etch the crystal surface, permanently degrading throughput and requiring factory replacement. Neutralize or dilute aggressive samples before measurement.

Factory Specification Sheet, ATR effective pH range
Process Limits
Sample volume of about 20 µL must fully cover the ATR surface

The ATR surface is 2.5 mm in diameter with a 2.6 µm effective pathlength. The sample must form a continuous film over the entire 2.5 mm surface; insufficient volume or poor contact produces weak or distorted spectra. Ensure the liquid wets the crystal fully before scanning.

Factory Specification Sheet, ATR surface diameter and sample volume
Maintenance
Clean the ATR crystal after every sample to prevent carryover

Residues left on the 2.5 mm ATR surface contaminate subsequent spectra and can attack the crystal if corrosive. Wipe the crystal with a suitable solvent and dry it between measurements; inspect for scratches or clouding that would reduce effective pathlength.

Factory Specification Sheet, ATR surface diameter

Selection & Integration Q&A

When should I choose the 4200 FlexScan handheld instead of the 4300 handheld or 4500/5500 portable models?

Choose the 4200 when onsite, hand-carried ATR identification is the primary task and the fixed single-reflection ATR (2.6 µm pathlength, pH 5–9) suits your samples. The 4300, 4500, and 5500 occupy other positions in the series; their specifications are not given here, so compare their sampling interfaces and portability against your sample types before deciding.

What adjacent system parts or sample conditions must be compatible with the 4200's ATR interface?

The ATR is integral, so no interchangeable module is required. Samples must be compatible with the crystal's pH 5–9 rating and must wet the 2.5 mm surface with roughly 20 µL. No electrical, interface, or controller specifications were provided, so power and data-connection requirements must be confirmed from the instrument manual.

What maintenance and consumables are needed, and what is not included in base delivery?

Routine maintenance is cleaning the ATR crystal after each sample to avoid carryover and crystal damage. No accessories, cables, calibration standards, or consumables are listed in the verified facts, so the base-delivery contents and any service intervals must be confirmed with Agilent; do not assume a calibration kit is included.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Agilent Cary 635 FTIR Spectrometer
Brochure ·4,1 МБ ·26 pp.
View PDF
PDF
Agilent Cary 635 FTIR
Brochure ·1,6 МБ ·10 pp.
View PDF