Agilent Technologies FTIR Microscopes & Imaging Systems
Agilent Technologies FTIR Microscopes & Imaging Systems — Molecular spectroscopy.
The 4200 FlexScan is a handheld FTIR spectrometer for onsite molecular analysis, covering 5100–600 cm⁻¹ with a 2.5 mm ATR surface and 2.6 µm effective pathlength. Its 3.8 kg housing and 20 cm bench footprint distinguish it from the larger 4300, 4500 and 5500 siblings. It is used for direct-contact identification of liquids and solids in the field.
Agilent Technologies FTIR Spectroscopy Series — Model Comparison & Selection
| Model | Wavelength range | Sample volume, milliliter | Atr path length, µm | Atr surface diameter, mm | Effective pathlength, µm | Optical aperture, mm |
|---|---|---|---|---|---|---|
| FTIR Microscopes & Imaging Systems Current | 5100...600 | 0.02 | 2.6 | 2.5 | 2.6 | 25 |
| Benchtop FTIR Instruments | 5100...600 | 0.02 | 2.6 | 2.5 | 2.6 | 25 |
| Compact & Portable FTIR Systems, Mobile FTIR | 5100...600 | 0.02 | 2.6 | 2.5 | 2.6 | 25 |
Full specifications
| Wavelength range | 5100...600 |
| Atr Surface Diameter | 2.5 mm |
| Effective Pathlength | 2.6 μm |
| Optical Aperture | 25 mm |
| Sample volume | 20 µL |
| Bench space required mfr | 20 cm |
| ATR spectral range mfr | 5100...600 |
| Spectrometer Body mfr | Glass-fiber reinforced polyamide for durability |
| Detector mfr | High-sensitivity thermoelectrically cooled deute |
| Interferometer mfr | 45 aperture |
| Bench space mfr | 20 cm |
| Spectral range (KBr optics) mfr | 7000...350 |
| Spectral range (ZnSe optics) mfr | 5100...600 |
| DialPath path lengths mfr | 30...1,000 microns |
| DialPath Modules mfr | 5100...600 |
| Sample Type mfr | Lower-concentration components, more dilute solu |
| ZnSe engine spectral range mfr | 5100...600 |
| KBr engine spectral range mfr | 7000...350 |
| DialPath pathlength repeatability mfr | 0.25 μm |
| DialPath custom pathlength mfr | 1000 μm |
| TumblIR fixed pathlength range mfr | 100 μm |
| Atr Path Length | 2.6 μm |
| Weight | 3.8 kg |
| Weight range | 3.5 kg |
| ATR effective path length mfr | 36.5 |
| Footprint mfr | 26.4 module |
| ATR effective pH range mfr | 1...14 |
| ATR pH range mfr | 5...9 |
| ZnSe ATR pH range mfr | 5...9 |
Description
Construction and series positioning
- Handheld FTIR with integrated single-reflection ATR; 3.8 kg mass and 20 cm bench space when docked.
- Spectral range 5100–600 cm⁻¹ shared with the ATR accessory; 25 mm optical aperture.
- Sits below the 4300 handheld, 4500 portable and 5500 compact benchtop in the FlexScan/portable family; choose this model when portability and direct ATR contact are the priority rather than benchtop automation.
Sampling behavior
- ATR surface diameter 2.5 mm with 2.6 µm effective pathlength; sample volume 20 µL.
- ATR effective pH range 5–9: strongly acidic or alkaline samples are outside the accessory's chemical window.
- No digitized curve points were supplied, so no spectral performance curves are asserted here.
Installation and operation
- The attached document digests cover the Cary 635 benchtop FTIR and its interchangeable modules, not the 4200 FlexScan itself; no installation, control or connection specifics for this handheld can be taken from them.
- No certificates or applications were supplied.
Integration & Operating Notes
The ATR accessory is rated for an effective pH range of 5 to 9. Samples outside this window can attack the crystal or coating, degrading the 2.6 µm effective pathlength and invalidating subsequent spectra; neutralize or use an alternative sampling interface.
The 2.5 mm ATR surface diameter and 20 µL sample volume define the contact area that must be fully wetted for a representative spectrum. Underfilling or spreading the sample beyond the crystal reduces signal and repeatability.
The instrument requires 20 cm of bench space in its docked/bench configuration. In handheld use the 3.8 kg mass must be supported during contact measurement; plan a stable surface or stand for repeatable ATR pressure.
Because the ATR crystal is the exposed optical interface, clean it after each measurement and inspect for scratches or chemical attack, particularly after samples near the pH 5–9 limits. No service interval is stated in the supplied documents.
Selection & Integration Q&A
Pick the 4200 when handheld, direct-contact ATR identification at 5100–600 cm⁻¹ is the task and 3.8 kg portability matters. The 4300 handheld, 4500 portable and 5500 compact benchtop are the neighboring options; no comparative specs for them were supplied, so confirm their ranges and interfaces before substituting.
The ATR presents a 2.5 mm surface with 2.6 µm effective pathlength and 20 µL sample volume, and tolerates pH 5–9 only. Any sample preparation or delivery hardware must present liquid or solid contact within that spot size and chemistry; no drive, power supply or controller interface data was supplied for this model.
The unit weighs 3.8 kg and needs 20 cm of bench space when docked. The supplied documents cover the Cary 635 benchtop, not this handheld, so no duty-cycle, IP rating or environmental limits can be quoted; confirm these with Agilent before continuous field deployment.
No accessories, cables or consumables are listed in the supplied facts, and no service interval is stated. The only maintenance-relevant fact is the ATR pH 5–9 window, so crystal cleaning and inspection after each sample should be planned; request the accessory and spares list from Agilent.