Agilent Technologies GC/MS Instruments, GC/MS Systems, GC/MS Analysis
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies GC/MS Instruments, GC/MS Systems, GC/MS Analysis

Agilent Technologies GC/MS Instruments, GC/MS Systems, GC/MS Analysis — Gas chromatography mass spectrometry gc ms.

The Agilent 7010D is a triple quadrupole GC/MS system with heated gold quadrupoles and a JetClean ion source, covering a mass range to 1050 m/z at attogram-level detection limits. It is the highest-sensitivity modification in the GC/TQ line, positioned above the single-quadrupole 5977C MSD family. It serves targeted trace analysis in complex matrices where peak-area RSD of 5% and S/N 100 are required.

Agilent Technologies GC/MS Series — Model Comparison & Selection

Model Mass rangeDetection limitSensitivityCarrier gasIon sourcePeak area rsd, %
GC/MS Instruments, GC/MS Systems, GC/MS Analysis Current 1050attogram-level——2.05
GC/MS Ion Sources, GC Inlets 1050—1002——

Full specifications

Core Performance & Functional Specifications
Detection limit attogram-level
Ion source 2.0
Peak Area Rsd 5 %
Sensitivity (S/N) mfr 100
Quadrupole mfr heated gold quadrupoles quadrupoles
Ion source cleaning mfr JetClean JetClean
Acquisition software mfr 13.0
Instrument uptime mfr 100 injections
Average instrument repair experience mfr 10 years
Parts available right away mfr 96
Parts accessible at worldwide logistics centers mfr Millions Millions
Repairs fixed during first visit mfr 85
Service engineers worldwide mfr 1850
Priority service call response time mfr 1...2 days
Dimensions, Weight & Mechanical Design
Mass range 1050 m/z
Mass spectrometer type mfr triple quadrupole quadrupole

Description

Construction and series positioning

Analytical behavior

Control and software

Integration & Operating Notes

Control & I/O
Plan for MassHunter Acquisition 13.0 as the control layer

Instrument control is provided through MassHunter Acquisition Software, listed at version 13.0. Workflows for targeted screening (ChemVista, PCDL, MRM databases) and nontargeted analysis run on the same suite, so the data-system specification should be fixed before the instrument is ordered.

Brochure MassHunter Software 5994-4923EN
Process Limits
Method transfer must respect the 5% peak-area RSD

Peak-area RSD is specified at 5%. Methods transferred from other GC/MS platforms should be re-validated against this figure, since precision depends on the ion source condition and the JetClean cleaning state at the time of acquisition.

Factory Specification Sheet
Maintenance
Use JetClean source cleaning to sustain sensitivity

The ion source is equipped with JetClean cleaning. Sensitivity is stated as S/N 100 and detection limit at attogram level; these figures depend on source cleanliness, so the JetClean routine should be scheduled as part of the preventive maintenance plan rather than run only after signal loss.

7010D Triple Quadrupole GC/MS 5994-7389EN

Selection & Integration Q&A

When should the 7010D triple quadrupole be chosen instead of a 5977C single-quadrupole GC/MSD?

Choose the 7010D when targeted trace analysis needs MS/MS selectivity and the stated 5% peak-area RSD at attogram-level detection limits. The 5977C family (EI, Inert Plus with HydroInert source, EI/CI, HES) is a single-quadrupole MSD line and is the appropriate neighbor when full-scan spectra and ion-source variants matter more than triple-quadrupole MRM sensitivity.

What companion GC and software must be specified alongside the 7010D?

The 7010D document references the 8890B and 8850 GC systems as companions, and instrument control runs through MassHunter Acquisition Software version 13.0. Targeted screening uses ChemVista, PCDL and MRM databases within the MassHunter suite, so the GC model and data-system configuration should be fixed together with the mass spectrometer.

What duty-cycle and environment limits are documented for this system?

The supplied digests contain no environmental or duty-cycle tables for the 7010D. The only operational figures given are the 5% peak-area RSD, S/N 100 and attogram-level detection limit; installation environment and duty cycle must be taken from the full 7010D manual, which is not included in the supplied extracts.

What maintenance and service items should be planned beyond base delivery?

The ion source uses JetClean cleaning, which should be scheduled to maintain the stated S/N 100 and attogram-level detection limit. The service program quotes 1–2 day priority response, 96% immediate parts availability and 85% first-visit repair; cables, consumables and service contracts are not listed in the supplied facts and must be confirmed at order.

Dimensional Drawings & Technical Documentation

Technical documentation