Agilent Technologies GPC/SEC Systems, Macromolecular Analysis and Solution
Agilent Technologies GPC/SEC Systems, Macromolecular Analysis and Solution — Liquid chromatography.
The Agilent GPC/SEC System is a dedicated gel-permeation/size-exclusion chromatography configuration within the InfinityLab HPLC series, built around a 4.6 mm internal-diameter column format and a typical flow rate of 1 mL/min. It is distinguished from analytical HPLC and 2D-LC siblings by its macromolecular-analysis purpose, supporting up to 6144 samples in automated operation with 9 ppm carryover. It serves as the separation engine for polymer molecular-weight distribution and solution-size characterization workflows.
Agilent Technologies HPLC Systems Series — Model Comparison & Selection
| Model | Max pressure, megapascal | Carryover, % | Column inner diameter, mm | Maximum pressure, bar | Sample capacity | Typical flow rate, mL/min |
|---|---|---|---|---|---|---|
| GPC/SEC Systems, Macromolecular Analysis and Solution Current | — | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
| 2D-LC System | 130 | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
| Analytical HPLC and UHPLC Systems | — | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
| Preparative HPLC Systems, InfinityLab LC Purification Solutions | — | 9×10⁻⁴ | 4.6 | 1300 | 6144 | 1 |
Full specifications
| Carryover | 9 ppm |
| Maximum pressure | 1300 bar |
| Sample Capacity | 6144 samples |
| Typical Flow Rate | 1 mL/min |
| Productivity range mfr | Micrograms Micrograms |
| Column Inner Diameter | 4.6 mm |
Description
Construction and series positioning
- This model is the GPC/SEC (macromolecular analysis and solution) member of the Agilent HPLC Systems series; sibling configurations cover 2D-LC, analytical/UHPLC, application-specific, and bio-inert/biocompatible HPLC.
- The verified configuration is defined by a 4.6 mm column inner diameter and a typical flow rate of 1 mL/min, i.e. an analytical-scale SEC column format rather than a preparative or bio-inert flow path.
- Sample capacity is stated as 6144 samples, indicating an automated, high-throughput autosampler configuration; carryover is 9 ppm.
Behavior and media
- No digitized curve points or pressure/flow-range data were supplied, so no retention, pressure or calibration behavior is asserted here. The only performance anchors are the 1 mL/min typical flow, 4.6 mm column ID and 9 ppm carryover.
- The 'productivity range' extra spec is recorded only as 'Micrograms' with no numeric value; it is therefore not usable as a quantitative rating and is not restated as one.
Installation, control and operation
- The attached brochures cover the broader InfinityLab LC portfolio (2D-LC, Bio LC, purification) and contain no model-specific installation, connection or control facts for this GPC/SEC configuration; no ordering codes or part numbers are printed in them.
- Consequently, electrical ratings, interface protocols and control-software specifics for this exact model are not documented in the supplied facts and must be taken from the model-specific user manual before integration.
Integration & Operating Notes
With 9 ppm carryover stated for this configuration, method sequences that quantify trace high-molecular-weight shoulders should include blank injections at the start and end of each batch to confirm the wash performance of the autosampler remains within this budget.
The attached brochures describe the InfinityLab LC portfolio generally and print no model-specific voltage, current, communication protocol or software-version facts for this GPC/SEC system. Obtain these from the model-specific user manual before specifying power, network or controller hardware.
The supplied document digests contain no maintenance schedule, error-code list or consumable part numbers for this GPC/SEC configuration. Service intervals and replacement parts must be taken from the model-specific manual; do not infer them from the 2D-LC, Bio LC or purification brochures.
Selection & Integration Q&A
Pick this one for macromolecular/solution SEC work at 4.6 mm column ID and ~1 mL/min with 6144-sample capacity and 9 ppm carryover. Choose the analytical/UHPLC sibling for small-molecule assays, the 2D-LC sibling for orthogonal multidimensional separations, and the Bio HPLC sibling for bio-inert flow paths.
They must support the verified 4.6 mm column format at a typical 1 mL/min and keep system carryover at the stated 9 ppm. The supplied brochures print no voltage, protocol or fitting data for this model, so pump/detector compatibility and connection details must be confirmed against the model-specific manual.
The supplied facts and document digests contain no ambient temperature, humidity, bench-load or duty-cycle figures for this GPC/SEC model. The 6144-sample capacity implies long unattended runs, but environmental and continuous-operation limits must be read from the model-specific user manual before installation.
No service intervals, error codes, cables or consumable part numbers are documented in the supplied digests; those brochures cover 2D-LC, Bio LC and purification portfolios only. Maintenance schedule and any cables, fittings or columns must be specified from the model-specific manual and ordering information.