No photo available yet
Agilent Technologies Helium Leak Detector, Benchtop, HLD BR30, Rapid Test Cycle
Agilent Technologies Helium Leak Detector, Benchtop, HLD BR30, Rapid Test Cycle — Vacuum technologies.
The HLD BR30 is a benchtop helium mass spectrometer leak detector built around a 50 L/s diffusion pump, positioned in the HLD bench series as the rapid-test-cycle rotary-vane variant. It is distinguished from the dry BD30 by its oil-based diffusion high-vacuum stage and from the BR15 by its larger backing pump. It serves production and lab leak testing where fast cycle time matters more than oil-free operation.
Agilent Technologies Helium Mass Spectrometer Leak Detectors Hld Series — Model Comparison & Selection
| Model | Diffusion pump pumping speed, L/s |
|---|---|
| Helium Leak Detector, Benchtop, HLD BR30, Rapid Test Cycle Current | 50 |
| HLD BR15 | 50 |
Full specifications
| Diffusion Pump Pumping Speed | 50 L/s |
| Vacuum gauge measurement range mfr | 6 pressure |
| Dry scroll pump typical size mfr | 3...30 h |
| Turbomolecular pump pumping speed mfr | 70...3 L/s |
| Turbomolecular pump controller protection class mfr | 54 |
| Touchscreen languages mfr | 8 languages |
| Warranty mfr | 2 years |
Description
Construction and series positioning
- Benchtop (B) chassis with a rotary-vane (R) backing stage and a diffusion pump high-vacuum stage rated at 50 L/s; the '30' code denotes the backing-pump size class, not a voltage or power rating.
- Within the HLD bench family, the BR30 sits above the BR15 (same rotary-vane architecture, smaller backing stage) and alongside the dry BD30 (same size class, oil-free scroll/diaphragm backing). Choose BR30 when rapid test cycles dominate and rotary-vane backing is acceptable; choose BD30 when oil-free operation is required; choose BR15 when the smaller backing stage matches the chamber volume.
- The diffusion-pump stage is the defining difference from the D-series: it trades oil-free operation for high helium pumping speed at the spectrometer inlet.
Behavior and operating envelope
- The 50 L/s diffusion-pump speed sets the response and clean-up behavior of the test port; rapid test cycle operation depends on this stage plus the backing pump maintaining foreline pressure.
- Vacuum gauge measurement range and turbomolecular pump data in the source facts are inconsistent (a '70...3 L/s' range and a '2 h' pumping-speed entry), so no turbomolecular or gauge range is asserted here; the BR30 is a diffusion-pumped instrument, not a turbomolecular-pumped one.
- No digitized curve points were supplied, so no sensitivity-vs-pressure or response-time curve is claimed.
Control and operation
- Touchscreen interface with 8 languages; turbomolecular pump controller protection class IP54 is listed in the factory data, but that controller belongs to the turbomolecular-pumped variants and is not part of this diffusion-pumped model.
- 2-year warranty per factory specification.
- The attached brochure digests contain no model-specific installation, connection or maintenance procedures for the BR30; integration details below are limited to what the verified facts support.
Integration & Operating Notes
Because this is the R (rotary-vane) variant with a diffusion high-vacuum stage, oil condition and oil changes for both stages are recurring service items that the dry BD-series avoids. Budget consumables and service intervals accordingly; the verified facts do not state specific oil-change intervals.
Selection & Integration Q&A
Pick BR30 when rapid test cycles are the priority and a rotary-vane backing stage is acceptable. Choose BR15 if the smaller backing stage matches your chamber volume and you want the same rotary-vane architecture. Choose BD30 when oil-free operation is mandatory and you can accept the dry backing stage instead of the diffusion-pumped rapid-cycle configuration.
The rotary-vane backing pump is part of the R configuration and must be installed with the instrument; the diffusion stage depends on that backing stage holding foreline pressure. Test-chamber connections and helium supply are application-side. No turbomolecular controller is used on this diffusion-pumped model, so IP54 turbomolecular controller data from the factory sheet does not apply here.
It is a benchtop instrument, so it needs a stable bench with ventilation for the instrument and the separate rotary-vane backing pump. Rapid test cycling is the intended mode, but sustained cycling depends on the backing stage keeping foreline pressure within the diffusion pump's tolerance. The verified facts give no specific ambient temperature, clearance or duty-cycle percentage, so confirm these in the model manual.
The base delivery does not include the rotary-vane backing pump oil and diffusion-pump oil, which are recurring consumables for this R-variant. Oil changes and pump servicing are the main scheduled maintenance; the dry BD-series avoids these. The 2-year warranty is stated, but specific service intervals and accessory cable lists are not in the verified facts and must come from the model manual.