Agilent Technologies HPLC/UHPLC Upgrades – Upgrade an existing HPLC system
Agilent Technologies HPLC/UHPLC Upgrades – Upgrade an existing HPLC system — Liquid chromatography.
The 1260 Infinity II GPC/SEC System is a high-performance gel-permeation/size-exclusion chromatography platform built from InfinityLab LC modules. This card covers the upgrade and supply ecosystem for the series, including 800 bar Quick Turn fittings, 200 mL/min pump heads, and 0.2 µm/47 mm filtration consumables. It is used to configure and maintain GPC/SEC workflows across 1220/1260/1290 Infinity II/III instruments.
Agilent Technologies Liquid Chromatography Series — Model Comparison & Selection
| Model | Carryover, % | Column inner diameter, mm | Filter membrane diameter, mm | Filter membrane pore size, µm | Filter pore size, µm | Ptfe frits per pm kit, pk |
|---|---|---|---|---|---|---|
| HPLC/UHPLC Upgrades – Upgrade an existing HPLC system Current | — | — | 47 | 0.2 | 2 | 5 |
| HPLC Instruments, UHPLC Systems, | 9×10⁻⁴ | 4.6 | — | — | — | — |
Full specifications
| Filter Membrane Diameter | 47 mm |
| Filter Membrane Pore Size | 0.2 μm |
| Filter Pore Size | 2 μm |
| Ptfe Frits Per Pm Kit | 5 pk |
| Pump Head Flow Rate | 200 mL/min |
| Solvent Bottle Volume | 1 L |
| Solvent Filtration Assembly Flask Volume | 1 L |
| Solvent Filtration Assembly Funnel Volume | 250 mL |
| Solvent Inlet Filter Pore Size | 10 μm |
| Well-plate Closing Mat Quantity | 50 pk |
| Well-plate Volume | 0.5 mL |
| Quick Connect heat exchanger flow rate mfr | 2.5 mL/min |
| Capillary dimensions mfr | 0.12 mm |
| Preventive maintenance cost reduction mfr | 30 |
| Pump seals per PM kit mfr | 4 |
| Seal cap assembly sets per PM kit mfr | 2 |
| Gold seals for outlet valve per PM kit mfr | 2 |
| Seal washes per PM kit mfr | 4 |
| Solvent bottles per convenience kit mfr | 3 amber |
| Recommended quantity mfr | 2 |
| Cost reduction from PM mfr | 30 |
| Finger caps pack size mfr | 15 pk |
| pressure stability mfr | 1300 bar |
| Quick Turn pressure (finger-tight) mfr | 600 bar |
| inline filter pore size (HPLC) mfr | 0.5 μm |
| high-flow heat exchanger volume mfr | 3.0 μL |
| low-dispersion heat exchanger volume mfr | 1.1 μL |
| high flow rate threshold mfr | 2.5 mL/min |
| Quick Turn Fitting Pressure Limit | 800 bar |
| Solvent bottle thread mfr | 45 |
| Fitting diameter mfr | 4.7 mm |
| Adapter thread mfr | 45 |
| Adapter material mfr | PTFE PTFE |
Description
Series positioning and modification scope
- The 1260 Infinity II GPC/SEC System sits in the InfinityLab LC family alongside the 1220 Infinity II analytical-scale and purification systems and the 1260 analytical-scale purification system.
- This entry describes the upgrade and consumable set for the series rather than a single fixed configuration: pump heads rated to 200 mL/min, Quick Turn fittings rated to 800 bar, and solvent/sample handling supplies are shared across 1260 Infinity II/III and 1290 Infinity II/III instruments.
- Sibling models differ by scale and detection intent: 1220 systems are compact analytical-scale units, while the 1260 purification variants add fraction collection; the GPC/SEC configuration is distinguished by size-exclusion separation and the associated filtration and solvent preparation supplies.
Fluidic and pressure behavior
- Quick Turn fittings carry an 800 bar pressure limit; capillary dimensions are 0.17 mm, and the Quick Connect heat exchanger operates at 2.5 mL/min.
- Solvent inlet filters are 10 µm; filtration assemblies use 47 mm membranes at 0.2 µm pore size, with 2 µm filters also listed for coarser filtration steps.
- Solvent bottles are 1 L with a 45 thread; PTFE adapters (4.7 mm fitting diameter, 45 thread) mate bottles to the inlet line.
Installation and maintenance architecture
- Preventive maintenance kits bundle two pump seals, two seal cap assembly sets, two gold seals for the outlet valve, and four seal washes; the supplier states a 30% PM cost reduction.
- Well plates are 0.5 mL with 50-pack closing mats; finger caps are supplied in 15-packs; PTFE frits come 5 per PM kit.
- The flyer digests cover supplies for 1220 Infinity II, 1260 Infinity II/III, and 1290 Infinity II/III series, including lamps, starter kits, and heat exchangers, but provide no additional numerical limits.
Integration & Operating Notes
Quick Turn fittings are rated to 800 bar; operating above this limit risks fitting failure and leakage. Verify the system pressure setpoint and pump head rating before installing fittings in high-pressure GPC/SEC methods.
Solvent filtration uses 47 mm membranes at 0.2 µm, with 2 µm filters also listed; inlet filters are 10 µm. Select the pore size according to the solvent and column protection requirement, since a finer membrane increases backpressure and filtration time.
Each preventive maintenance kit includes two pump seals, two seal cap assembly sets, two gold seals for the outlet valve, and four seal washes. Plan seal replacement as a paired service so both pump channels are refreshed together.
The supplier states a 30% preventive maintenance cost reduction when using the bundled PM kit rather than individual parts. This figure is a supplier claim and should be validated against local service pricing.
1 L solvent bottles have a 45 thread; PTFE adapters with a 4.7 mm fitting diameter and 45 thread connect the bottle to the solvent inlet line. Confirm thread compatibility before ordering replacement bottles or adapters.
Selection & Integration Q&A
Choose the GPC/SEC configuration for size-exclusion separations requiring the InfinityLab supply set (0.2 µm filtration, 800 bar fittings, 200 mL/min pump heads). The 1220 analytical-scale system suits compact routine analysis, while the 1260 purification variant adds fraction collection for preparative work.
Quick Turn fittings are rated to 800 bar, and capillaries are 0.17 mm. Adjacent components must be rated at least to the system's maximum operating pressure; the Quick Connect heat exchanger operates at 2.5 mL/min and should be plumbed with matching fittings.
Use 1 L solvent bottles with 45-thread PTFE adapters (4.7 mm fitting), 10 µm inlet filters, and 47 mm filtration membranes at 0.2 µm (2 µm also listed). Filter mobile phase before use to protect columns and reduce baseline noise.
The PM kit includes two pump seals, two seal cap assembly sets, two gold seals for the outlet valve, and four seal washes. Solvent bottles, filtration membranes, frits, well plates, and finger caps are separate supply items and are not included with the base instrument.