Agilent Technologies icp-ms-automation-systems
Agilent Technologies icp-ms-automation-systems — Atomic spectroscopy.
The Agilent ICP Automation System is a two-syringe autodilutor integrated with a four-rack autosampler, delivering 360-sample capacity and up to 400-fold dilution from a single stock solution. It doubles throughput versus the SPS 4 and is controlled by ICP Expert 7.7+ or MassHunter 5.3+. It serves automated sample introduction and dilution for 5800/5900 ICP-OES and 7850/7900/8900 ICP-MS.
Agilent Technologies Automation Systems Series — Model Comparison & Selection
| Model | Sample capacity | Width, cm |
|---|---|---|
| icp-ms-automation-systems Current | 360 | 15.8 |
| icp-oes-automation-systems | 360 | 15.8 |
Full specifications
| Sample Capacity | 360 samples |
| Maximum dilution factor mfr | 400 fold |
| Dilution range of single stock solution mfr | 1 x |
| Autosampler rack capacity mfr | four sample rack rack |
| Sample capacity increase vs SPS 4 mfr | 50 |
| Sample throughput mfr | doubles doubles |
| Compatible ICP-OES instruments mfr | 5800 |
| Compatible ICP-MS instruments mfr | 7850 |
| ICP-OES software version mfr | 7.7 above |
| ICP-MS software version mfr | 5.3 above |
| Syringe configuration mfr | two-syringe syringe |
| Maximum dilution factor (single stock solution) mfr | 1 x |
| Sample rack count mfr | six sample rack rack |
| Sample throughput increase mfr | doubles doubles |
| maximum dilution factor mfr | 400 fold |
| SPS 6 sample capacity mfr | 540 samples |
| Width | 15.8 cm |
Description
Construction and series positioning
- This modification is the ICP autodilutor/autosampler package built around the ADS 2 two-syringe dilutor and a four-rack autosampler; the sibling ICP-OES automation entry covers the same workflow family for ICP-OES.
- Sample capacity is 360 samples, a 50% increase over the SPS 4, with throughput stated as doubled.
- The unit is 15.8 cm wide; dilution is performed from a single stock solution over a 1x range up to a maximum factor of 400.
Behavior and media
- Two syringes handle sample and diluent separately, allowing on-line dilution without manual preparation; the maximum dilution factor of 400 is the operating ceiling for a single stock solution.
- No digitized performance curves are supplied, so flow and dilution accuracy cannot be characterized beyond the stated factor and range.
Control and integration
- Operation requires Agilent ICP Expert software v7.7 or above for ICP-OES (5800 series) and ICP-MS MassHunter v5.3 or above for ICP-MS (7850/7900/8900).
- The system works with the Advanced Valve System (AVS 7 / AVS MS) as the switching valve stage; the brochure covers ADS 2, AVS 7/AVS MS and SPS 4/SPS 6 as one workflow family.
Integration & Operating Notes
The ADS 2 dilutor is driven by the instrument software, not a standalone controller: ICP Expert must be v7.7 or higher on 5800/5900 ICP-OES and MassHunter v5.3 or higher on 7850/7900/8900 ICP-MS. Upgrading the instrument software is therefore a prerequisite before the hardware can be commissioned.
The two-syringe design prepares all dilutions from a single stock solution with a 1x range and a maximum factor of 400. Samples requiring higher dilution must be pre-diluted offline or run through a second preparation step; planning the calibration range around this ceiling avoids failed runs.
The two-syringe dilutor and the AVS switching valve are separate modules in the workflow; syringe seals, tubing and valve rotor are wear items to be stocked and replaced on a service schedule. Confirm which of these are included with the base system versus ordered as accessories.
Selection & Integration Q&A
Pick this system when the workflow spans both ICP-OES (5800/5900) and ICP-MS (7850/7900/8900) and needs on-line dilution up to 400-fold with 360-sample capacity. The ICP-OES sibling covers the OES-only automation path; choose it when no ICP-MS instrument is in the lab.
The ADS 2 dilutor works with the Advanced Valve System (AVS 7 or AVS MS) as the switching stage and requires ICP Expert v7.7+ (ICP-OES) or MassHunter v5.3+ (ICP-MS). The instrument software version must be verified before commissioning.
The two-syringe dilutor and AVS switching valve are separate workflow modules; syringe seals, tubing and valve rotor are wear items to be stocked. Confirm rack types and valve configuration against the order, as the brochure lists ADS 2, AVS 7/AVS MS and SPS 4/SPS 6 as distinct items.