No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies 6.0 CFM

Agilent Technologies 6.0 CFM — Vacuum technologies.

The Agilent IDP 6.0 CFM is a dry scroll pump sized at 6.0 CFM, positioned between the 5.4 CFM and 20.60 CFM siblings in the IDP series. It serves as the backing/roughing stage for high-vacuum systems, with the diffusion-pump pumping speed of 50 L/s listed in the matched performance data. No electrical, ultimate-pressure or interface ratings are verified for this exact model.

Agilent Technologies Idp Pumps Series — Model Comparison & Selection

Model Motor power, kWUltimate pressure, mbarPumping speed, m³/hBase pressure, mbarSupply frequency, HzOperating temperature, °C
6.0 CFM Current ——————
20.60 CFM 0.1193.33.63.350—
26.48 CFM 0.1193.33.63.350—
IDP-4 0.1192.43.63.3—5
Scroll Pumps for Helium Recirculation & Cryogenic Applications 0.119—3.63.3——

Full specifications

Core Performance & Functional Specifications
Diffusion Pump Pumping Speed 50 L/s
Vacuum gauge measurement range mfr 6 pressure
Dry scroll pump typical size mfr 3...30 h
Turbomolecular pump pumping speed mfr 70...3 L/s
Interfaces, Connections & Control
Turbomolecular pump controller protection class mfr 54

Description

Construction and series positioning

Behavior and media

Installation and operation

Integration & Operating Notes

Electrical
Motor power and supply voltage are not stated for this model

Sibling models list 0.16 HP, but no electrical rating is verified for the 6.0 CFM variant; do not size branch protection, cabling or controller output from sibling data. Obtain the model-specific electrical data before integration.

Factory Specification Sheet (sibling model data

Selection & Integration Q&A

When should I choose the IDP 6.0 CFM rather than the 5.4 CFM or 20.60 CFM siblings?

Pick the 6.0 CFM when the required displacement falls between the 5.4 CFM and 20.60 CFM siblings. The 20.60 CFM and 26.48 CFM carry 0.16 HP motor data and 60 L/min / 3.3 mbar figures; no such data is verified for the 6.0 CFM, so confirm its curve before final selection.

What adjacent-system data must I obtain before integrating this pump as a backing stage?

The matched data gives only a 50 L/s diffusion-pump pumping speed; no inlet flange, ultimate pressure or electrical rating is verified for this model. Confirm flange size, supply voltage and controller compatibility against the model-specific datasheet before connecting to the high-vacuum stage.

Are there mounting, environment or duty-cycle limits documented for this model?

No model-specific mounting, ambient or duty-cycle limits are present in the supplied facts; the attached brochures are application-level e-mobility documents without installation content. Operating position and environment must be taken from the IDP 6.0 CFM instruction manual.

What maintenance schedule and accessories come with the base delivery?

No service interval, consumable list or included-accessory list is verified for this model; the 3...30 h figure in the extra specs is a generic dry-scroll size, not a schedule. Tip-seal kits, cables and controllers must be confirmed as separate items from the IDP manual and price list.

Dimensional Drawings & Technical Documentation

Technical documentation