Agilent Technologies Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems
Agilent Technologies Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems — Liquid chromatography with Pumping speed 3×10⁻⁵ m³/h.
The Infinity III LC upgrade is a field-installed conversion kit that brings existing HPLC/UHPLC systems to Infinity III functionality, using a 2.1 mm column (part 959758) with 1.8 µm particles and a 10 mm flow cell. It is distinguished within the series from injector-focused upgrade kits by its full flow-path and detection update. It serves laboratories modernizing legacy LC platforms for higher-resolution separations without replacing the entire instrument.
Agilent Technologies HPLC Uhplc Upgrades Series — Model Comparison & Selection
| Model | Pumping speed, m³/h | Column particle size, µm | Depth, mm | Filter membrane pore size, µm | Flow cell path length, mm | Frequency, Hz |
|---|---|---|---|---|---|---|
| Infinity III LC upgrades | Upgrade existing HPLC/UHPLC systems Current | 3×10⁻⁵ | 1.8 | — | 0.22 | 10 | — |
| Upgrade kits for HPLC injector improve functionality | — | — | 795 | — | — | 50 |
Full specifications
| Pumping speed | 0.5 mL/min |
| Column Particle Size | 1.8 µm |
| Filter Membrane Pore Size | 0.22 µm |
| Solvent A mfr | Water Water |
| Solvent B mfr | ACN ACN |
| Column dimensions mfr | 2.1 mm |
| Software version mfr | 2.8 later |
| Flow Cell Path Length | 10 mm |
| Column part number mfr | 959758 |
Description
Construction and positioning
- This upgrade modifies existing HPLC/UHPLC systems rather than being a standalone instrument; it is one of several upgrade paths in the Infinity III LC series.
- The sibling model 'Upgrade kits for HPLC injector improve functionality' addresses injector performance only (3 A motor power), whereas this kit covers the broader flow path and detection chain.
- The kit is specified around a 2.1 mm internal diameter column (part number 959758) packed with 1.8 µm particles, a 10 mm path-length flow cell, and 0.22 µm filter membranes for mobile-phase preparation.
Behavior under load and in different media
- The method uses a binary mobile phase of water (Solvent A) and acetonitrile (Solvent B) at a pumping speed of 0.5 mL/min.
- The 1.8 µm particle size and 2.1 mm column format are consistent with UHPLC-level separations; the 10 mm flow cell supports sensitive detection in the upgraded optical path.
- No digitized curve points are available for this upgrade, so pressure/flow behavior cannot be characterized beyond the stated method conditions.
Installation, connection and control
- The attached document digests provide no actionable installation or control facts; the technical overview covers barcode-based sample confirmation with the InfinityLab Sample ID Reader on 1290 Infinity III Multisampler systems, not this upgrade kit.
- Software version 2.8 is noted as a later requirement, but the digests do not specify control interfaces, drivers, or connection details for the upgrade.
- No certificates or application notes are supplied with the verified facts.
Integration & Operating Notes
The specification lists 0.22 µm filter-membrane pore size, indicating that mobile phases must be filtered to this rating to protect the 1.8 µm column and the 10 mm flow cell from particulate contamination. Omitting this step risks column blockage and increased backpressure in the upgraded flow path.
The extra specifications list software version 2.8 with the qualifier 'later', but the attached document digests do not describe the control software, drivers, or firmware for this upgrade. The engineer must confirm the actual required software release and compatibility with the existing data system before installation.
Selection & Integration Q&A
Choose this kit when the goal is a full flow-path and detection update around a 2.1 mm, 1.8 µm column and 10 mm flow cell. The sibling injector upgrade kit (3 A motor) addresses injector functionality only; select it when sample introduction is the sole limitation and the existing separation and detection hardware is adequate.
The method requires a 2.1 mm column (part 959758) with 1.8 µm particles, a 10 mm path-length flow cell, and 0.22 µm filter membranes for mobile-phase preparation. Water (Solvent A) and acetonitrile (Solvent B) are the specified mobile phase; the pump must deliver 0.5 mL/min. No drive or controller details are given in the verified facts.
The verified facts and attached document digests contain no mounting, environmental, or duty-cycle specifications for this upgrade kit. The digests cover sample ID reading and system brochures, not installation limits. These parameters must be obtained from the full instruction manual before planning the installation.
The only maintenance-related fact is the 0.22 µm mobile-phase filtration requirement; no service intervals are stated. The 2.1 mm column (part 959758) and filter membranes are consumables that may not be part of the base upgrade delivery. Software version 2.8 is listed as a later requirement, so the required software release must be confirmed separately.