Agilent Technologies 4 Laser Flow Cytometer, NovoCyte Quanteon

Agilent Technologies 4 Laser Flow Cytometer, NovoCyte Quanteon — Research flow cytometry.

The NovoCyte Quanteon is a 4-laser solid-state flow cytometer with onboard thermal-electric laser cooling, silicon photomultiplier detection per fluorescence channel, and volumetric absolute counting at 5% precision. It acquires up to 100,000 events/second across a 5–120 µL/min sample flow range, positioning it between the 1–3 laser Advanteon and the 5-laser Penteon in the NovoCyte series.

Agilent Technologies Flow Cytometer Systems Series — Model Comparison & Selection

Model Pumping speed, m³/hSample flow rate, µL/minSheath flow rate, mL/minVolumetric absolute count precision, %Laser power, WPrint technology
4 Laser Flow Cytometer, NovoCyte Quanteon Current —5...1206.550.405Solid state laser with o
1,2, or 3 Laser Benchtop Flow Cytometer, NovoCyte Advanteon  —5...1206.550.405Solid state laser with o
1-3 laser benchtop flow cytometer, NovoCyte 3×10⁻⁶5...1206.55——
5 Laser Flow Cytometer, NovoCyte Penteon —5...1206.550.405Solid state laser with o

Full specifications

Core Performance & Functional Specifications
Laser power 405 mW
Print technology Solid state laser with onboard thermal-electric cooling
Sample Flow Rate 5...120 μL/min
Sheath Flow Rate 6.5 mL/min
Ssc Sensitivity 0.1 μm
Volumetric Absolute Count Precision 5 %
Laser beam profile mfr 10 μm
Fluorescence detection mfr Silicon photomultiplier with individual photodet
FSC sensitivity mfr 0.4 μm
Fluorescence threshold sensitivity mfr 40 MESF
Fluorescence resolution mfr 3 % CV
Flow cell mfr 170 μm
Sample acquisition rate mfr 100000 events/second
Sample acquisition volume mfr 5 mL
Manual sample format mfr 12 tube

Description

Construction and series positioning

Measurement behavior

Installation and operation

Integration & Operating Notes

Process Limits
Acquisition rate ceiling is 100,000 events/second

Sample acquisition rate is specified up to 100,000 events/second; samples concentrated enough to exceed this event rate at the chosen sample flow will exceed the stated acquisition capability, so dilution or a lower sample flow rate must be planned before running high-concentration samples.

Datasheet System Specifications NovoCyte Quanteon 5994-1033EN
Maintenance
Manual format is 12 tubes; no automation facts verified

The verified manual sample format is 12 tubes and the sample acquisition volume is 5 mL. The attached datasheet digest contains no loader, automation, cleaning or service-interval facts, so automation accessories and maintenance schedules cannot be specified from the verified material.

Datasheet System Specifications NovoCyte Quanteon 5994-1033EN

Selection & Integration Q&A

When should the 4-laser Quanteon be chosen over the Advanteon or Penteon?

Pick the Quanteon when the panel needs four laser lines; the Advanteon covers 1–3 lasers and the Penteon 5. All three share the NovoCyte platform, so the choice is optical package size, not a different detection principle.

What sample-side requirements must be met for volumetric absolute counting?

Volumetric absolute count precision is 5% with sample flow adjustable 5–120 µL/min and a 5 mL acquisition volume; the sample must be delivered within this flow window, and the 12-tube manual format defines the sample presentation.

What mounting and environmental limits apply to this instrument?

The verified datasheet digest contains no environmental, bench-load or clearance figures for the Quanteon, so site requirements cannot be quoted from the supplied facts; they must be taken from the full instrument manual before installation planning.

What maintenance schedule and accessories are verified for the Quanteon?

No service intervals, cleaning routines, cables or consumables are stated in the verified datasheet digest; only the 12-tube manual sample format and 5 mL acquisition volume are confirmed, so accessories and service plans must be confirmed separately.