Agilent Technologies Protein Capillary Electrophoresis Instrument
Agilent Technologies Protein Capillary Electrophoresis Instrument — Automated electrophoresis.
The Agilent ProteoAnalyzer is an automated capillary electrophoresis instrument for protein sizing and quantification, using the Protein Broad Range P240 kit. It analyzes 12 samples simultaneously per run in about 30 minutes, covering 10–240 kDa and 2–2,000 ng/µL. It is distinguished within the Proteoanalyzer series by its dedicated protein chemistry and broad-range kit compatibility.
Agilent Technologies Proteoanalyzer Systems Series — Model Comparison & Selection
| Model | Sensitivity | Run time, min | Software | Analysis time for 12 samples, minutes | Detector type | Lower marker size, kDa |
|---|---|---|---|---|---|---|
| Protein Capillary Electrophoresis Instrument Current | 1 | 30 | — | — | — | 6 |
| CE-SDS Protein Analysis Capillary Array, ProteoAnalyzer | — | 30 | Agilent ProSize data ana | 30 | charge-coupled device | — |
Full specifications
| Sensitivity | 1 PBS |
| Lower Marker Size | 6 kDa |
| Overall Average Size (bsa) | 69.2 kDa |
| Overall Average Size (caii) | 28.0 kDa |
| Resolution | 1 milligram |
| Run Time | 30 min |
| Typical Sizing Accuracy (lm And Um) | 10 % |
| Typical Sizing Accuracy (lm Only) | 15 % |
| Typical Sizing Accuracy (% Sizing Error) | 15 % |
| Samples analyzed simultaneously per run mfr | 12 samples |
| Detection concentration range mfr | 2...2,000 ng/μL |
| Upper marker precision benefit mfr | 200 kDa |
| Sample buffer mfr | 1 PBS |
| CAII extinction coefficient mfr | 0.575 |
| Sizing precision mfr | 8 % CV |
| Sample input concentration range mfr | 2...2,000 ng/μL |
| Overall accuracy (BSA) mfr | -10.25 % error |
| Overall precision (BSA) mfr | 1.53 % CV |
| Overall accuracy (CAII) mfr | -19.43 % error |
| Overall precision (CAII) mfr | 1.43 % CV |
| Linearity R2 (CAII) mfr | 0.9998 |
| Sizing range (LM only) mfr | 10...240 kDa |
| Resolution (NIST mAb NGHC/HC) mfr | 1 |
| Sizing precision (LM only) mfr | 8 mAb |
| Sizing precision (LM only, intact NIST mAb) mfr | 10 %CV |
| Sizing precision (LM and UM) mfr | 5 mAb |
| Overall accuracy BSA mfr | -19.43 % error |
| Overall accuracy CAII mfr | -3.55 % error |
| Overall precision BSA mfr | 13.71 %CV |
| Overall precision CAII mfr | 2.10 %CV |
| Linearity R2 CAII mfr | 0.9998 |
| Linearity R2 mfr | 0.9381 |
| Quantitative Range mfr | 2 PBS |
| Quantification Reproducibility mfr | 20...2,000 BSA |
| Quantification reproducibility (low range) mfr | 2...20 BSA |
| Sample volume required mfr | 1 μL |
| Capillary array channels mfr | 12 channel |
| SDS-PAGE separation time mfr | 40 minutes |
| Heat denaturation time mfr | 5 minutes |
| DTT final concentration mfr | 50 mM |
| SDS-PAGE loading volume mfr | 10 μL |
| SDS-PAGE separation voltage mfr | 200 V |
| Sensitivity (Signal/Noise > 3) mfr | 1 PBS |
Description
Construction and positioning
- The ProteoAnalyzer is a capillary electrophoresis instrument configured for SDS-protein analysis, not a general-purpose DNA/RNA analyzer.
- It is positioned as the protein-specific member of the Proteoanalyzer Systems series; the sibling capillary array (CE-SDS Protein Analysis Capillary Array) is a consumable/accessory, not an alternative instrument configuration.
- The system is supplied for use with the Protein Broad Range P240 kit (part number 5191-6640), which defines the supported size and concentration ranges.
Performance behavior
- Sizing range is 10–240 kDa; lower marker is 6 kDa, upper marker is 200 kDa.
- Sample input concentration range is 2–2,000 ng/µL.
- Typical sizing accuracy is 10% when both lower and upper markers are used, and 15% with lower marker only; a separate 15% sizing-error figure is also listed.
- Sizing precision is 8% CV; typical resolution is 10.
- For BSA, overall average size is 69.2 kDa (range 67.99–69.84 kDa), overall accuracy −10.25% error, overall precision 1.53% CV.
- For CAII, overall average size is 28.0 kDa (range 27.17–27.87 kDa), overall accuracy −19.43% error, overall precision 1.43% CV; linearity R² is 0.9998.
- Run time is approximately 30 minutes for 12 samples analyzed simultaneously.
Installation, control and operation
- The available document digests (technical overviews and a general safety guide) contain no installation, connection, control, or maintenance procedures; those specifics are not asserted here.
- The general safety guide covers the ProteoAnalyzer among Agilent automated capillary electrophoresis systems and is limited to safety information.
Integration & Operating Notes
Samples outside the 10–240 kDa sizing range or outside 2–2,000 ng/µL input concentration fall outside the stated kit performance; accuracy and precision figures apply only within these ranges and with the specified marker mode.
Using both lower and upper markers yields typical sizing accuracy of 10%, while lower-marker-only operation is stated at 15%; the upper marker (200 kDa) provides the stated precision benefit, so method design must select the marker mode deliberately.
The Protein Broad Range P240 kit (5191-6640) and the CE-SDS Protein Analysis Capillary Array are distinct items from the instrument; the available digests do not specify replacement intervals or base-delivery contents.
Selection & Integration Q&A
The ProteoAnalyzer is the instrument; the CE-SDS Protein Analysis Capillary Array is a consumable used with it. Choose the instrument for automated protein sizing/quantification; the array is a replacement/consumable item, not an alternative system.
Use the Protein Broad Range P240 kit (5191-6640). Sizing accuracy is 10% with lower and upper markers versus 15% with lower marker only; the upper marker is 200 kDa and the lower marker 6 kDa.
Input concentration must be 2–2,000 ng/µL and protein size within 10–240 kDa for the stated performance; outside these ranges the accuracy and precision figures do not apply.
The available document digests contain no maintenance schedule, service intervals, or accessory/cable list; only the P240 kit and capillary array are identified as separate consumables. Consult the instrument manual for service details.