Agilent Technologies Trace sulfur analysis
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies Trace sulfur analysis

Agilent Technologies Trace sulfur analysis — Gas chromatography with Motor power 2.35 kW.

The Agilent Trace Sulfur Analysis is a configured 8890-series GC analyzer dedicated to trace sulfur measurement, built on the 8890A/B platform with a 54 × 54 × 50 cm, 50 kg bench footprint. It is distinguished within the Environmental GC Analyzer series by its sulfur-specific configuration rather than by hardware ratings. It serves as the analytical stage in process and environmental gas streams where sulfur species must be quantified at trace levels.

Motor power
2.35 kW

Agilent Technologies Environmental GC Analyzers Series — Model Comparison & Selection

Model Motor power, kWDepth, mmFrequency, HzHeight, cmMaximum altitude, mPower outlet current, Amp
Trace sulfur analysis Current 2.355400.550461520
Analyzers to measure and monitor GHG emissions 2.355400.550461520

Full specifications

Core Performance & Functional Specifications
Motor power 2350 W
Dimensions, Weight & Mechanical Design
Depth 54 cm
Height 50 cm
Weight 50 kg
Width 54 cm
Electrical, Power & Drive Specifications
Frequency 50 % Hz
Power Outlet Current 20 Amp
Line voltage mfr 120 VAC
Current rating mfr 19.6 amps
Operating Conditions, Environment & Protection
Maximum Altitude 4615 m
Operating humidity range mfr 5...95
Storage humidity range mfr 5...95

Description

Construction and positioning

Electrical and environmental envelope

Operation and control

Integration & Operating Notes

Electrical
Dedicate a 20 A outlet to the analyzer circuit

The specified 20 A power outlet current and 13.4 A current rating leave limited headroom on a shared branch. The analyzer should be placed on a circuit sized for its own draw so that oven and accessory loads do not trip the breaker during a run.

Factory Specification Sheet
Environment
Keep the lab within 15–35 °C and 5–95 % humidity

Operation outside the stated ambient range can affect retention-time stability and detector response in trace sulfur work, where small baseline shifts matter. The storage range of 40–70 °C applies only to non-operating transport and must not be used as an operating allowance.

Factory Specification Sheet

Selection & Integration Q&A

When should I choose the trace sulfur configuration instead of the GHG emissions analyzer in the same series?

Choose this configuration when the analytical target is sulfur species at trace levels. The sibling model is configured for measuring and monitoring greenhouse gas emissions. Both are built on the Agilent 8890A/B GC platform, so the decision is driven by the species to be quantified, not by hardware class.

What supply and circuit must be provided for this analyzer?

The matched specs give 220 VAC at 13.4 A with a 20 A outlet requirement, but the 8890 site preparation checklist covers 120 VAC Americas and 220/230/240 VAC builds. Confirm the delivered configuration on the nameplate and size the branch circuit to the checklist before installation.

What maintenance and accessories are defined for this configuration?

No maintenance schedule, consumables list or accessory set was supplied for this configuration; the only attached document is the 8890 GC site preparation checklist, which covers the data system PC and power cord options. Service intervals and consumables must be taken from the instrument manual for the delivered build.