No photo available yet
Agilent Technologies System Upgrades for Flow Cytometry
Agilent Technologies System Upgrades for Flow Cytometry — Research flow cytometry.
The Agilent system-upgrades-for-flow-cytometry is a reagent-and-panel upgrade package for the NovoCyte Opteon spectral flow cytometer, not a standalone instrument. It supplies a 45-color full-spectrum panel and a 30-color conventional panel, both built around the Opteon's 5-laser, 30-detector architecture. It is used to extend existing Opteon installations into high-parameter immunophenotyping of human PBMCs and murine lung/spleen digests.
Full specifications
| Blue Laser Wavelength | 488 nm |
| Cell Strainer Pore Size | 70 µm |
| Centrifugation Time | 7 minutes |
| Collagenase Ii Concentration | 500 µg/mL |
| Dnase I Concentration | 150 µg/mL |
| Edta Concentration | 0.5 M |
| Lung/spleen Digestion Volume | 3 mL |
| Maximum Emission Wavelength | 660 nm |
| Pulmonary Lavage Volume | 10 mL |
| Red Laser Wavelength | 637 nm |
| Time Post Infection | 35 days |
| Uv Laser Wavelength | 349 nm |
| Violet Laser Wavelength | 405 nm |
| Yellow-green Laser Wavelength | 561 nm |
| Number of lasers mfr | five five |
| Number of fluorescence detectors mfr | 30 |
| Panel size mfr | 30 colors |
| Mouse infection dose mfr | 5 PFU |
| Cells per test (dilution basis) mfr | 3 cells |
| Number of colors in panel mfr | 45 colors |
| Cytometer mfr | NovoCyte Opteon Opteon |
| Red laser central wavelength mfr | 660 nm |
| Number of colors mfr | 30 |
| Laser central wavelength mfr | 660 nm |
| Centrifugation speed mfr | 400 g |
| Fluorescence detectors mfr | 30 |
| Dissociation incubation time mfr | 30 minutes |
| EDTA hold time mfr | 2 minutes |
| Centrifugation force mfr | 400 g |
| Staining incubation time mfr | 30 minutes |
| Viability dye dilution mfr | 1 |
| Viability dye incubation time mfr | 15 minutes |
| Cells per staining reaction mfr | 3 cells |
| Antibody cocktail volume mfr | 50 μL |
| excitation laser wavelengths mfr | 349 nm |
| fluorescence detectors mfr | 70 |
| centrifugation speed mfr | 500 g |
| antibody incubation time (whole blood) mfr | 15 minutes |
| lysis incubation time mfr | 10 minutes |
| PBMC antibody incubation time mfr | 30 minutes |
| FcX incubation time mfr | 10 minutes |
| bead antibody incubation time mfr | 30 minutes |
| bead wash volume mfr | 1 mL |
| BSA concentration in wash buffer mfr | 0.2 |
| PFA concentration in resuspension mfr | 1 |
| FBS concentration in staining buffer mfr | 2 |
| Digestion Incubation Temperature | 37 °C |
| True-Stain Monocyte Blocker part number mfr | 426102 |
| CellBlox Blocking Buffer part number mfr | 001 |
| Zombie NIR viability dye part number mfr | 423105 |
| CD45RA BUV395 part number mfr | 740315 |
| CD45RO StarBright UltraViolet 445 part number mfr | 461 |
| CD16 BUV496 part number mfr | 612945 |
| CCR5(CD195) BUV563 part number mfr | 741401 |
| CD314(NKG2D) BUV615 part number mfr | 751232 |
| CD39 BUV661 part number mfr | 749967 |
| CD8 BUV805 part number mfr | 612889 |
| CCR7(CD197) BV421 part number mfr | 353208 |
| CD123 Super Bright 436 part number mfr | 62 |
| CD11c eFluor 450 part number mfr | 48 |
| IgD BV480 part number mfr | 566187 |
| CD3 BV510 part number mfr | 344827 |
| IgG BV605 part number mfr | 563246 |
| CD28 BV650 part number mfr | 302945 |
| CCR6(CD196) BV711 part number mfr | 353435 |
| CXCR5(CD185) BV750 part number mfr | 747111 |
| CD141 BB515 part number mfr | 565084 |
| CD57 FITC part number mfr | 555619 |
| CD14 Spark Blue 550 part number mfr | 367148 |
| CD33 StarBright Blue 580 part number mfr | 1271 |
Description
What this modification actually is
- The model code describes an upgrade/panel package for the NovoCyte Opteon spectral cytometer, not a separate flow cytometer. The base instrument is the Opteon, with 5 lasers and 30 fluorescence detectors.
- Two panel configurations are documented: a 45-color full-spectrum panel for human PBMC leukocyte subset characterization, and a 30-color immunophenotyping panel for influenza-infected mouse models.
- Sibling models in the series (flow cytometers, flow cytometer systems, flow cytometry automation, NovoCyte Advanteon) are separate hardware lines; this package is specific to the Opteon platform.
Panel and assay behavior
- The 45-color panel uses spectral unmixing across the Opteon's 30 detectors; the 30-color panel uses conventional compensation on the same 5-laser architecture (UV 349 nm, violet 405 nm, blue 488 nm, yellow-green 561 nm, red 637 nm).
- The 30-color mouse panel includes a defined infection model: 5 PFU mouse infection dose, 35 days post-infection, with lung/spleen digestion in 3 mL using 500 µg/mL collagenase II and 150 µg/mL DNase I at 37 °C, 400 g centrifugation, 70 µm cell strainer, and 10 mL pulmonary lavage.
- Reagent part numbers are specified for the 45-color panel, including True-Stain Monocyte Blocker (426102), CellBlox Blocking Buffer (001), Zombie NIR viability dye (423105), and a full antibody list (e.g., CD45RA BUV395 740315, CD8 BUV805 612889, CD3 BV510 344827).
Installation and operation
- The upgrade is delivered as panel/reagent definitions and protocols applied to an existing Opteon; no electrical, mounting, or control-interface specifications are given in the verified facts.
- Operation follows the application notes: sample preparation per the 30-color mouse protocol or PBMC isolation for the 45-color panel, then acquisition on the Opteon with the defined gating strategy.
- No certificates, environmental limits, or maintenance schedules are stated in the verified facts; these must be taken from the Opteon instrument manual.
Integration & Operating Notes
The 30-color mouse immunophenotyping panel is documented at 5 PFU infection dose and 35 days post-infection. Using a different dose or timepoint shifts the leukocyte subset distribution and the panel's gating strategy may no longer apply as written.
The 45-color PBMC panel is designed for the NovoCyte Opteon full-spectrum cytometer with 30 fluorescence detectors. It cannot be transferred unchanged to a conventional compensation-only cytometer, because the panel relies on spectral unmixing across the 5-laser configuration.
The 45-color panel specifies exact part numbers for blockers, viability dye, and each antibody (e.g., True-Stain Monocyte Blocker 426102, Zombie NIR 423105, CD45RA BUV395 740315). Substituting a different clone or fluorochrome changes the spectral signature and requires re-validation of the unmixing matrix.
Selection & Integration Q&A
Choose this package when you already run a NovoCyte Opteon and need validated high-parameter panels: 45-color full-spectrum for human PBMCs or 30-color conventional for mouse influenza models. The Advanteon and other sibling lines are separate hardware; this package does not convert them.
The panel requires the Opteon's 5-laser, 30-detector configuration plus the listed reagents: True-Stain Monocyte Blocker 426102, CellBlox Blocking Buffer 001, Zombie NIR 423105, and the specified antibody clones/part numbers. PBMC isolation materials are not included and must be sourced separately.
The verified facts list no maintenance schedule, cables, or consumables in the base package. All antibodies, blockers, viability dye, digestion enzymes, and PBMC isolation reagents are separate purchases identified by part number in the application notes; instrument service intervals must come from the Opteon manual.