No photo available yet

Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies System Upgrades for Flow Cytometry

Agilent Technologies System Upgrades for Flow Cytometry — Research flow cytometry.

The Agilent system-upgrades-for-flow-cytometry is a reagent-and-panel upgrade package for the NovoCyte Opteon spectral flow cytometer, not a standalone instrument. It supplies a 45-color full-spectrum panel and a 30-color conventional panel, both built around the Opteon's 5-laser, 30-detector architecture. It is used to extend existing Opteon installations into high-parameter immunophenotyping of human PBMCs and murine lung/spleen digests.

Full specifications

Core Performance & Functional Specifications
Blue Laser Wavelength 488 nm
Cell Strainer Pore Size 70 µm
Centrifugation Time 7 minutes
Collagenase Ii Concentration 500 µg/mL
Dnase I Concentration 150 µg/mL
Edta Concentration 0.5 M
Lung/spleen Digestion Volume 3 mL
Maximum Emission Wavelength 660 nm
Pulmonary Lavage Volume 10 mL
Red Laser Wavelength 637 nm
Time Post Infection 35 days
Uv Laser Wavelength 349 nm
Violet Laser Wavelength 405 nm
Yellow-green Laser Wavelength 561 nm
Number of lasers mfr five five
Number of fluorescence detectors mfr 30
Panel size mfr 30 colors
Mouse infection dose mfr 5 PFU
Cells per test (dilution basis) mfr 3 cells
Number of colors in panel mfr 45 colors
Cytometer mfr NovoCyte Opteon Opteon
Red laser central wavelength mfr 660 nm
Number of colors mfr 30
Laser central wavelength mfr 660 nm
Centrifugation speed mfr 400 g
Fluorescence detectors mfr 30
Dissociation incubation time mfr 30 minutes
EDTA hold time mfr 2 minutes
Centrifugation force mfr 400 g
Staining incubation time mfr 30 minutes
Viability dye dilution mfr 1
Viability dye incubation time mfr 15 minutes
Cells per staining reaction mfr 3 cells
Antibody cocktail volume mfr 50 μL
excitation laser wavelengths mfr 349 nm
fluorescence detectors mfr 70
centrifugation speed mfr 500 g
antibody incubation time (whole blood) mfr 15 minutes
lysis incubation time mfr 10 minutes
PBMC antibody incubation time mfr 30 minutes
FcX incubation time mfr 10 minutes
bead antibody incubation time mfr 30 minutes
bead wash volume mfr 1 mL
BSA concentration in wash buffer mfr 0.2
PFA concentration in resuspension mfr 1
FBS concentration in staining buffer mfr 2
Operating Conditions, Environment & Protection
Digestion Incubation Temperature 37 °C
Standards, Safety & General Data
True-Stain Monocyte Blocker part number mfr 426102
CellBlox Blocking Buffer part number mfr 001
Zombie NIR viability dye part number mfr 423105
CD45RA BUV395 part number mfr 740315
CD45RO StarBright UltraViolet 445 part number mfr 461
CD16 BUV496 part number mfr 612945
CCR5(CD195) BUV563 part number mfr 741401
CD314(NKG2D) BUV615 part number mfr 751232
CD39 BUV661 part number mfr 749967
CD8 BUV805 part number mfr 612889
CCR7(CD197) BV421 part number mfr 353208
CD123 Super Bright 436 part number mfr 62
CD11c eFluor 450 part number mfr 48
IgD BV480 part number mfr 566187
CD3 BV510 part number mfr 344827
IgG BV605 part number mfr 563246
CD28 BV650 part number mfr 302945
CCR6(CD196) BV711 part number mfr 353435
CXCR5(CD185) BV750 part number mfr 747111
CD141 BB515 part number mfr 565084
CD57 FITC part number mfr 555619
CD14 Spark Blue 550 part number mfr 367148
CD33 StarBright Blue 580 part number mfr 1271

Description

What this modification actually is

Panel and assay behavior

Installation and operation

Integration & Operating Notes

Process Limits
Infection model timing is fixed at 35 days post-infection

The 30-color mouse immunophenotyping panel is documented at 5 PFU infection dose and 35 days post-infection. Using a different dose or timepoint shifts the leukocyte subset distribution and the panel's gating strategy may no longer apply as written.

Application Note: 30-color panel, NovoCyte Penteon (5994-5872EN
Control & I/O
45-color panel requires spectral unmixing on the Opteon

The 45-color PBMC panel is designed for the NovoCyte Opteon full-spectrum cytometer with 30 fluorescence detectors. It cannot be transferred unchanged to a conventional compensation-only cytometer, because the panel relies on spectral unmixing across the 5-laser configuration.

Application Note: 45-color spectral panel, NovoCyte Opteon (5994-7397EN
Maintenance
Reagent part numbers must match the published panel list

The 45-color panel specifies exact part numbers for blockers, viability dye, and each antibody (e.g., True-Stain Monocyte Blocker 426102, Zombie NIR 423105, CD45RA BUV395 740315). Substituting a different clone or fluorochrome changes the spectral signature and requires re-validation of the unmixing matrix.

Application Note: 45-color spectral panel, NovoCyte Opteon (5994-7397EN

Selection & Integration Q&A

When should I choose this Opteon upgrade package instead of the NovoCyte Advanteon or the base flow cytometer line?

Choose this package when you already run a NovoCyte Opteon and need validated high-parameter panels: 45-color full-spectrum for human PBMCs or 30-color conventional for mouse influenza models. The Advanteon and other sibling lines are separate hardware; this package does not convert them.

What adjacent system parts and reagents are required to run the 45-color panel?

The panel requires the Opteon's 5-laser, 30-detector configuration plus the listed reagents: True-Stain Monocyte Blocker 426102, CellBlox Blocking Buffer 001, Zombie NIR 423105, and the specified antibody clones/part numbers. PBMC isolation materials are not included and must be sourced separately.

What maintenance, consumables, or accessories are not included in the base delivery?

The verified facts list no maintenance schedule, cables, or consumables in the base package. All antibodies, blockers, viability dye, digestion enzymes, and PBMC isolation reagents are separate purchases identified by part number in the application notes; instrument service intervals must come from the Opteon manual.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
A 30-Color Immunophenotyping Panel
Manual ·4,0 МБ ·8 pp.
View PDF
PDF
Capability of Spectral Flow Cytometry
Brochure ·1,8 МБ ·7 pp.
View PDF