Agilent Technologies TriScroll 300, Two-Stage, Dry, Inverter-Driven Pump
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies TriScroll 300, Two-Stage, Dry, Inverter-Driven Pump

Agilent Technologies TriScroll 300, Two-Stage, Dry, Inverter-Driven Pump — Vacuum technologies with Motor power 0.5 kW, Noise level 50 dB, Temperature 20 °C.

The TriScroll 300 Inverter is a two-stage dry scroll pump driven by an integrated single-phase-to-three-phase inverter, reaching 1.3 mbar ultimate pressure at a peak pumping speed of 250 l/min (8.9 cfm). Its 35–65 Hz speed range, factory-set at 62 Hz, distinguishes it from fixed-speed siblings and allows pressure-linked speed control. It serves as a clean, oil-free roughing stage for mass spectrometry and other contamination-sensitive vacuum systems.

Motor power
0.5 kW
Noise level
50 dB
Temperature
20 °C
Ultimate pressure
1.3 mbar

Agilent Technologies TriScroll Series — Model Comparison & Selection

Model Motor power, kWStorage temperature, °CNoise level, dBUltimate pressure, mbarOperating speed, rpmShipping weight
TriScroll 300, Two-Stage, Dry, Inverter-Driven Pump Current 0.5-20...60501.3334.233.6
TriScroll 600, Two-Stage, Dry, Inverter-Driven Pump 1-6.67501.3145041

Full specifications

Core Performance & Functional Specifications
Motor power 0.67 HP
Noise level 50 dB
Temperature 20 °C
Ultimate pressure 1.3 mbar
Coverslip type Clean air. No toxic, corrosive, explosive or particulate forming gases
Inlet Pressure 1.0 atmosphere
Operating Speed 35 Hz
Rotational speed 35 Hz
Peak pumping speed mfr 250
Exhaust connection mfr 1 Thread
Gas ballast connection mfr 16
Power requirements mfr 200 amps
Maximum continuous inlet pressure mfr 100 Torr
Maximum outlet pressure mfr 1.1 atmosphere
Gas ballast mfr 1 Thread
Motor thermal protection mfr Automatic Automatic
Installation and storage mfr 2 storage
Peak pumping speed (TS300inv) mfr 250 hr
Peak pumping speed (TS600inv) mfr 500 h
Ultimate pressure (TS600inv) mfr 9.3 mbar
Europe mfr 10 m
Denmark mfr 10 m
Switzerland mfr 10 m
UK/Ireland mfr 13 m
India mfr 10 m
Israel mfr 10 m
North America mfr 10 m
Ultimate pressure (Torr) mfr 1.0 Torr
Major Maintenance Kit mfr 300 pumps.
Maintenance Tool Kit mfr 300 pumps.
Tip Seal Tool Kit mfr 300 pumps.
Replacement Tip Seal Set mfr 300 pumps.
Tip Seal Replacement Manual mfr 300 models
Pump Module Replacement Manual mfr 300 models
Major Maintenance Manual mfr 300 models
Advance Exchange TriScroll 300 Pump Module Only mfr 0300 SC
Service/Rebuild TriScroll 300 Inverter Pump mfr 0300 KMA
Fax: 1 781 860 9252 mfr please visit our website for individual office i
Gas ballast flow rate mfr 5 lpm
Vibration reduction mfr 86
HEPA filter efficiency mfr 99.97
HEPA particle size mfr 0.3 microns
Dimensions, Weight & Mechanical Design
Shipping Weight 33.6 kg
Weight 26 kg
Weight – pump only mfr 26 kg
Weight (TS600inv) mfr 31 kg
Bearing purge pressure mfr 2 less
Bearing purge pressure limit mfr 5 psig
Electrical, Power & Drive Specifications
Circuit Breaker Capacity 10 A
Frequency 65 Hz
Input voltage 200 V
Motor Line Current 5 A
Operating voltage mfr 50
Main fuse mfr 10 V
Normal Operation maximum power mfr 750 W
Interfaces, Connections & Control
Inlet connection 25
Gas ballast port mfr 1 NPT
Interface dimensions mfr 1
Operating Conditions, Environment & Protection
Cooling System Air-cooled
Noise level 50 dB
Storage temperature -20...60 °C
Pollution degree mfr 2
Altitude mfr 2000 m
Protection level mfr 20
Standards, Safety & General Data
Noise level (per ISO 11201) mfr 55 dB
Vibration level at inlet (per ISO 10816-1) mfr Variable with frequency frequency
Noise level per ISO 11201, variable w/frequency mfr 55 dBA

Description

Construction and series positioning

Behavior under load and in different modes

Installation, connection and control

Integration & Operating Notes

Control & I/O
Pump will not start unless P1 interlock links are fitted

The supplied mating connector must be plugged into P1 with pins 4–5 and pins 8–9 connected together. Without these links the inverter stays disabled, so wiring the interlock into a system E-stop or door circuit must preserve continuity during normal run.

User Manual, Pump Electrical Controller, page 16; Table 4, page 17
Electrical
Match supply and cord to the 200–240 VAC inverter rating

The standard inverter accepts 200–240 VAC single-phase, 50–60 Hz ±10%; 100–120 VAC operation requires the separate inverter P/N S4897001. Size the branch circuit for 5 A at 200 VAC and fit a 10 A circuit breaker; extension cords must be at least 16-gauge and no longer than 25 ft (7.6 m) to avoid voltage drop and overheating.

User Manual, Installation Requirements, pages 10–11; Table 3, page 13
Process Limits
Keep continuous inlet pressure below 100 Torr

Continuous operation above 100 Torr inlet risks overheating and damage; maximum outlet pressure is 1.1 atmosphere. The inverter's 750 W power ceiling also means the pump will self-reduce frequency under heavy gas load rather than exceed its power budget, so plan roughing cycles around the 100 Torr ceiling.

User Manual, Table 3, page 13; Pump Electrical Controller, page 16
Process Limits
Cap bearing purge nitrogen below 5 psig at about 5 lpm

When pumping high water vapor, feed dry nitrogen to the bearing purge port at roughly 5 lpm with pressure ≤2 psig and never above 5 psig. The purge kit PTSPURGEKIT is a separate accessory; the standard gas ballast uses a sintered filter, and blocking the gas ballast port is not recommended.

User Manual, Gas Ballast and Bearing Purge, page 20
Mounting
Install indoors within 5–40 °C and keep fan ducts clear

Ambient operating range is +5 °C to +40 °C; storage −20 °C to +60 °C. The pump is air-cooled, so fan ducts must not be blocked and the unit must sit on a stable surface indoors. For vibration-sensitive instruments, the vibration isolation kit replaces the standard feet and typically cuts transmitted vibration by 86% on this model.

User Manual, Installation Requirements, page 10; Table 3, page 13; Vibration Isolation Kit, page 24
Maintenance
Allow up to 24 h run-in after tip seal replacement

After replacing tip seals, the pump may need up to 24 hours of running before it reaches full rotational speed and stable base pressure — do not judge the service as failed before that window. Bearing grease replenishment and tip seal replacement are the scheduled interventions, triggered when base pressure rises.

User Manual, Maintenance, page 27

Selection & Integration Q&A

When should I choose the TriScroll 300 Inverter rather than the TriScroll 600 or the fixed-speed 15/30 m3/hr variants?

Pick the 300 Inverter when 250 l/min (8.9 cfm) at 1.3 mbar ultimate is enough and you want variable speed (35–65 Hz) for noise or pressure-linked control. The TriScroll 600 gives 1.0 kW for higher throughput at the same ultimate; fixed-speed variants suit simple, always-on roughing without inverter control.

What must I provide on the electrical and control side to run this pump in an automated system?

A 200–240 VAC single-phase supply (50–60 Hz ±10%) on a 10 A breaker, the P1 mating connector with pins 4–5 and 8–9 linked, and optionally a 0–10 V analog signal for remote speed (>9 V full, <1 V minimum). J2 gives RS232/RS485 monitoring up to 9600 baud via T-Plus software.

What isolation valve timing and inlet protection does the manual require for this pump?

A fast-acting normally closed isolation valve must open at least 350 ms after pump startup and close within 250 ms of shutoff to prevent debris backstreaming; VPI kits are available. For particle-sensitive processes, the HEPA inlet filter is rated 99.97% for particles >0.3 microns.

Which accessories and consumables are not in the base delivery, and what maintenance do they support?

Base delivery excludes the exhaust silencer kit, vibration isolation kit, HEPA inlet filter, bearing purge kit PTSPURGEKIT, isolation valve kits, CT-100 speed control kit and the 100–120 VAC inverter. Scheduled service is bearing grease replenishment and tip seal replacement when base pressure rises, followed by up to 24 h run-in.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
Agilent TriScroll Variable Speed Dry Pumps
Datasheet ·657,6 КБ ·4 pp.
View PDF
PDF
TriScroll 300 Inverter
Manual ·34 pp.
View PDF