Agilent Technologies TriScroll 600, Two-Stage, Dry, Inverter-Driven Pump
Agilent Technologies ·Made in USA · In Active Production

Agilent Technologies TriScroll 600, Two-Stage, Dry, Inverter-Driven Pump

Agilent Technologies TriScroll 600, Two-Stage, Dry, Inverter-Driven Pump — Vacuum technologies with Motor power 1 kW, Noise level 50 dB, Ultimate pressure 1.3 mbar.

The TriScroll 600 is a two-stage, dry, inverter-driven scroll pump configured for 220–230 V 50 Hz single-phase operation only, delivering 420 l/min peak pumping speed and 9.3 × 10⁻³ mbar ultimate pressure. It is optimized for helium leak detection and clean inert-gas service, with a 1.0 HP motor and NW25/NW40 inlet. Within the Triscroll series it sits above the TS300 in capacity while sharing the same ultimate pressure.

Motor power
1 kW
Noise level
50 dB
Ultimate pressure
1.3 mbar

Agilent Technologies TriScroll Series — Model Comparison & Selection

Model Motor power, kWStorage temperature, °CNoise level, dBUltimate pressure, mbarOperating speed, rpmShipping weight
TriScroll 600, Two-Stage, Dry, Inverter-Driven Pump Current 1-6.67501.3145041
TriScroll 300, Two-Stage, Dry, Inverter-Driven Pump 0.5-20...60501.3334.233.6

Full specifications

Core Performance & Functional Specifications
Motor power 1.0 kW
Noise level 50 dB
Ultimate pressure 1.3 mbar
Coverslip type Clean air. No toxic, corrosive, explosive or particulate forming gases
Operating Speed 1450 RPM
Peak pumping speed mfr 250 hr
Exhaust connection mfr 1 swivel
Gas ballast connection mfr 16
Power requirements mfr 200 amps
Maximum recommended continuous inlet pressure mfr 50 Torr
Maximum outlet pressure mfr 1.1 atmosphere
Gas ballast mfr 1 NPT
Operating voltages mfr 220 % VAC
Motor full load currents mfr 4.60 amps
Motor protection mfr Type U automatic automatic
Vibration level at inlet mfr 6.3 mm/sec
Installation mfr 1
Safety mfr 2006
Maximum outlet pressure*** mfr 1.1 atmosphere
Maintenance Tool Kit mfr 600 pumps
Replacement Tip Seal Set mfr 600 pumps.
S4807001 mfr Exhaust Extension Extension
PTS600EXFIL mfr Exhaust Filter Kit Kit
PTSPURGEKIT mfr Purge Kit Kit
Will not start. mfr Motor thermal protector open open
Poor ultimate pressure mfr System leak leak
Pump runs intermittently mfr Motor thermal protector is cycling open and clos
Clearance mfr 20 cm
Hoist capacity mfr 100 kg
Maximum exhaust back pressure mfr 1.5 psig
Peak pumping speed (TS300inv) mfr 250 hr
Peak pumping speed (TS600inv) mfr 500 h
Ultimate pressure (TS600inv) mfr 9.3 mbar
Dimensions, Weight & Mechanical Design
Shipping Weight 41 lbs
Weight 33 lbs
Weight – pump only mfr 26 kg
Weight (TS300inv) mfr 26 kg
Weight (TS600inv) mfr 31 kg
Electrical, Power & Drive Specifications
Full Load Motor Current 4.65 A
Maximum inlet pressure at nominal voltage mfr 1.0 atmosphere
Operating voltages** Single phase mfr 220
Interfaces, Connections & Control
Inlet connection 25
Gas ballast port mfr 1 NPT
Interface dimensions mfr 355.8 pump
Operating Conditions, Environment & Protection
Cooling System Air-cooled
Noise level 50 dB
Operating temperature 5 °C
Storage temperature 20 °F
Ambient Relative Humidity mfr 5 condensing
Sound Pressure Levels mfr 59 dB
Altitude mfr 2000 m
Ambient relative humidity mfr 5
Hammering noise mfr Pump overheated overheated
Relative humidity mfr 5...95
Standards, Safety & General Data
Peak pumping speed (ISO 21360-1: 2020) (ISO 21360-2: 2020) mfr 50 hr
Ultimate Pressure* (ISO 21360-1: 2020) (ISO 21360-2: 2020) mfr 7.0 Torr
Motor rating: EN 60034-1-2:2007 EN 60034-30 (GB 18613-2020) mfr 1.0 HP
Sound Pressure Levels (EN ISO 2151:2008) (ISO 4871:1996) (ISO 11201:2010) mfr 59 dB
Vibration level at inlet (per ISO 10816-1) mfr 6.3 mm/sec
Noise level per ISO 11201, variable w/frequency mfr 55 dBA

Description

Construction and series positioning

Behavior under load and media

Installation, control and operation

Integration & Operating Notes

Electrical
Supply must stay within ±10% of 220–230 V at 50 Hz

The pump is factory-configured for high-voltage 50 Hz operation only and cannot be reconnected for 60 Hz or 100–115 V. Mains fluctuations beyond ±10% risk motor overheating and invalid performance; verify the branch circuit before installation.

User Manual, Table 1 and Electrical Connections, page 160
Electrical
No power switch: pump starts as soon as the cord is plugged in

There is no on/off control on the pump; applying mains power starts the motor immediately. Install an accessible disconnect device or switched outlet, and confirm inlet and exhaust connections are secure before energizing.

User Manual, Preparation for Installation, page 144; Startup Procedure, page 147
Electrical
Size branch protection for ~31–32 A starting current

Full-load current is 4.65 A at 220 V and 4.60 A at 230 V, but starting current reaches approximately 31–32 A. Circuit breakers, wiring and any extension cord must be rated accordingly; extension cords are limited to 3-wire, minimum 14 AWG, maximum 25 ft (7.6 m).

User Manual, Table 2, page 159; Extension Cords, page 161
Process Limits
Keep continuous inlet pressure at or below 50 Torr

Operating continuously above the maximum recommended inlet pressure of 50 Torr can damage the scroll mechanism or shorten tip-seal life. For processes with higher gas loads, throttle the inlet or select a larger pump rather than running the TS600 above this limit.

User Manual, Table 1, page 154
Process Limits
Exhaust backpressure must not exceed 1.5 psig

Maximum outlet pressure is 1.1 atmosphere (1.5 psig). Restricted or undersized exhaust lines raise backpressure and cause overheating; use short, large-diameter exhaust plumbing and avoid filters or silencers that add significant restriction.

User Manual, Table 1, page 154; Mechanical Connections, page 162
Cooling & Media
Maintain 20 cm clearance on all sides for air cooling

The pump is air-cooled and surface temperatures above 80 °C are potentially damaging. Blocking vents or installing in a confined cabinet without airflow leads to overheating and thermal trips; keep at least 20 cm (8 in.) free space around the system.

User Manual, Grounding Instructions, page 146; Environmental Conditions, page 150; Startup Procedure, page 148
Maintenance
Run gas ballast after storage or high water-vapor exposure

If ultimate pressure is not reached after initial installation or storage, activate gas ballast for roughly 30 minutes to 24 hours before assuming a fault. Regular gas ballast operation removes condensed water and tip-seal dust and is part of the preventive maintenance plan.

User Manual, Preparation for Installation, page 144; Gas Ballast, page 165
Maintenance
Disconnect mains before service: thermal protector auto-restarts

The motor has an auto-reset thermal protector that restarts the pump automatically once the motor cools. Before any maintenance, isolate the mains supply to prevent unexpected restart and injury from the cooling fan.

User Manual, Troubleshooting footnote, page 173; Cleaning and Preventive Maintenance, page 167

Selection & Integration Q&A

When should I choose the TriScroll 600 over the TS300 or the smaller 15/30 m³/hr models?

Pick the TS600 when you need 420 l/min peak speed at 9.3 × 10⁻³ mbar for helium leak detection or inert-gas duty. The TS300 gives the same ultimate pressure at lower throughput; the 15 and 30 m³/hr models suit smaller chambers. All are dry scroll, but only the TS600 50 Hz variant is fixed at 220–230 V.

What inlet and exhaust hardware and backing configuration does the TS600 require?

Inlet is NW25 or NW40; exhaust is 5/8" hose barb or NW25. Use short, large-diameter lines and a bellows hose at the inlet for vibration isolation. The pump is a two-stage dry scroll and does not require a backing pump for its specified ultimate pressure; exhaust must stay below 1.5 psig.

What are the mounting, ambient and duty-cycle limits for installing this pump?

Install indoors at 5–40 °C and 5–95% RH non-condensing, with at least 20 cm free space on all sides for air cooling. The bench must support 33 kg. Continuous inlet pressure must stay at or below 50 Torr, and exhaust backpressure below 1.5 psig; the auto-reset thermal protector will trip if these are exceeded.

What maintenance parts and accessories are not included with the base pump?

Base delivery does not include the Major Maintenance Kit PTSS0600MK, Maintenance Tool Kit PTSS0600TK, or Replacement Tip Seal Set PTSS0600TS, nor the optional exhaust extension, exhaust filter kit, or purge kit. The pump has no oil to change; tip-seal replacement and gas ballast operation form the core service plan.

Dimensional Drawings & Technical Documentation

Dimensional drawings

performance curve performance curve

Click drawing to inspect vector dimensions

Technical documentation

PDF
TriScroll 600 Series Dry Scroll Vacuum Pump User Manual
Manual ·179 pp.
View PDF
PDF
Agilent TriScroll Variable Speed Dry Pumps
Datasheet ·657,6 КБ ·4 pp.
View PDF