Agilent Technologies VHS-6 Diffusion Pump
Agilent Technologies VHS-6 Diffusion Pump — Vacuum technologies with Motor power 1.45 kW, Pumping speed 4320 m³/h.
The VHS-6 is a 4-stage, self-aligning stainless-steel jet diffusion pump in the VHS small series, rated 1200 l/s air with standard cold cap and 1.2 Torr·l/s maximum throughput. It sits between the VHS-4 and VHS-250, requiring a 17 cfm backing pump and 0.25 gpm cooling water at 15 psi. It serves as the high-vacuum stage in systems needing stable operation below 10⁻³ Torr.
Agilent Technologies Small Diffusion Pumps Series — Model Comparison & Selection
| Model | Motor power, kW | Pumping speed, m³/h | Cooldown time, minutes | Cooling water pressure, psi | Diffusion pump pumping speed, L/s | Warm up time, minutes |
|---|---|---|---|---|---|---|
| VHS-6 Diffusion Pump Current | 1.45 | 4320 | 10 | 15 | 50 | 10 |
| VHS-250 Diffusion Pump | 1.45 | 4320 | 10 | 15 | 50 | 10 |
| VHS-4 Diffusion Pump | 1.45 | 4320 | 10 | 15 | 50 | 10 |
Full specifications
| Motor power | 1450 Watts |
| Pumping speed | 1200 l/s |
| Cooldown Time | 10 minutes |
| Diffusion Pump Pumping Speed | 50 L/s |
| Warm-up Time | 10 minutes |
| Vacuum gauge measurement range mfr | 6 pressure |
| Dry scroll pump typical size mfr | 3...30 h |
| Turbomolecular pump pumping speed mfr | 70...3 L/s |
| Optimum Operating Range mfr | 1 Torr |
| Maximum Forepressure mfr | 0.65 Torr |
| Backstreaming Rate at Pump Inlet mfr | with std cold cap cap |
| Backing Pump Size mfr | 10 cfm |
| Recommended Jet Assembly mfr | 4 steel |
| Turbomolecular pump controller protection class mfr | 54 |
| Cooling Water Pressure | 15 psi |
| Cooling Water Requirements mfr | 60 °F |
| Cooling Water Flow mfr | 0.25 gpm |
| Thermal Switches mfr | 300 °F |
Description
Construction and series positioning
- The VHS-6 uses a 4-stage, self-aligning stainless-steel jet assembly common to the VHS series, with a standard cold cap for backstreaming suppression.
- Within the series, the VHS-6 is the mid-size pump: the VHS-4 is rated 1200 l/s air (same as VHS-6 per Table 1-1) but requires only a 10 cfm backing pump, while the VHS-250 reaches 3700 l/s air and 4600 l/s helium and also uses a 17 cfm backing pump.
- The VHS-6 is distinguished by its 17 cfm backing-pump requirement and 0.25 gpm cooling-water flow, matching the VHS-250 but not the VHS-4.
Behavior under load and operating range
- Maximum throughput is 1.2 Torr·l/s (1.6 mbar·l/s) in the operating range; gas loads above this will exceed pumping capability.
- Maximum forepressure (no load) is 0.65 Torr (0.87 mbar); the backing pump must keep foreline pressure below this for the jet to function.
- Prolonged operation at high throughput above 10⁻³ Torr (1.33×10⁻³ mbar) can cause high chamber contamination and should be avoided.
- Warm-up and cooldown times are each 10 minutes, allowing predictable cycle timing.
Installation, connection, and control
- Cooling water must be supplied at 0.25 gpm and 15 psi, with inlet temperature between 60 and 80 °F (15–26 °C).
- Thermal switches are manual-reset at 300 °F (149 °C); if tripped, the pump must cool before reset.
- Maximum ambient temperature is 113 °F (45 °C).
- Electrical: motor power is 1450 W; the pump will not start if safety circuits or protective devices (flow switches, interlocks, thermostat) prevent the contactor from staying closed.
- Leak checks should focus on inlet and foreline connections, drain and fill plugs, compression fittings, and threaded connections.
Integration & Operating Notes
The maximum forepressure (no load) is 0.65 Torr (0.87 mbar); if the backing pump cannot maintain this, the diffusion jet stalls and high-vacuum performance collapses. Size the backing line and pump accordingly, and monitor foreline pressure during high gas loads.
Cooling water flow for the VHS-6 is 0.25 gpm at 15 psi, with maximum inlet temperature 60/80 °F (15–26 °C). Insufficient flow or excessive inlet temperature will trip the thermal switch or degrade pumping performance; install a flow switch interlocked with the heater circuit.
The pump will not start if safety circuits and/or protective devices prevent the contactor from staying closed. Check utilities, flow switches, interlocks, and thermostat operation before troubleshooting the heater or motor; a manual-reset thermal switch at 300 °F (149 °C) must be reset after cooling.
Selection & Integration Q&A
Choose the VHS-6 when you need 1200 l/s air pumping speed and can supply a 17 cfm backing pump and 0.25 gpm cooling water. The VHS-4 also delivers 1200 l/s but needs only a 10 cfm backing pump; the VHS-250 is for higher gas loads (3700 l/s air, 4600 l/s helium) and also requires 17 cfm backing.
A backing pump of at least 17 cfm is required to achieve maximum throughput, and the foreline must be sized to keep pressure below 0.65 Torr (no-load maximum forepressure). Include a foreline valve and gauge; check foreline connections for leaks as part of commissioning.
The base delivery does not include pump fluid, cooling-water fittings, or a cold cap (standard cold cap is referenced for ratings). Maintenance includes checking inlet/foreline connections, drain and fill plugs, and fittings for leaks; the thermal switch is manual-reset at 300 °F. Replacement parts and jet assemblies are listed in the manual.