BINDER MKFT 240
BINDER ·Made in Germany · In Active Production

BINDER MKFT 240

BINDER MKFT 240 — Climate chambers with Temperature -70…180 °C.

The BINDER MKFT 240 is a 228 L alternating climate chamber with deep-temperature capability to -70 °C and humidity control from 10 to 98 % RH. It is the mid-size 400 V model in the MKFT series, positioned between the MKFT 115 and MKFT 720, and is distinguished by a 400 W maximum heat compensation load. It is used for cyclic temperature/humidity testing of components and materials under programmable profiles.

Temperature
-70…180 °C

BINDER MKFT Series — Model Comparison & Selection

Model Temperature, °CHumidity range, % rhInterior volume, LLoad per rack, kgMax heat compensation, WNominal power, kW
MKFT 240 Current -70–18010...98228304006
MKFT 115 -70–18095115304005
MKFT 720 -70–18010...987344080011

Full specifications

Core Performance & Functional Specifications
Temperature -70...180 °C
Interior volume 228 L (MKFT240-400V)
Load per rack 30 kg (MKFT240-400V)
Maximum heat compensation 400 W
Nominal power 6 kW (MKFT240-400V)
Article Number mfr 9020
Electrical, Power & Drive Specifications
Power frequency 50 Hz (MKFT240-400V)
Rated voltage 400 V
Unit fuse 16.0 A (MKFT240-400V)
Operating Conditions, Environment & Protection
Humidity range 10...98 % RH
Cooling down time from 180°C to -70°C mfr 110 min
Humidity fluctuation with humidity dependent on set value mfr 2.5 % r.F.
Standards, Safety & General Data
Average heating-up rate according to IEC 60068-3-5 between -40°C and 180°C mfr 5.0 K/min

Description

Construction and series positioning

Behavior under load and in different media

Installation, connection and control

Integration & Operating Notes

Electrical
Requires 400 V 3-phase supply with 16 A fusing

The chamber draws 6 kW nominal at 3 N/PE 400 V 50 Hz and must be protected by a 16 A fuse or circuit breaker. Verify that the site supply can deliver this without voltage drop, especially if other high-load equipment shares the circuit.

Data Sheet Model MKFT 240 en.pdf; Technical data
Process Limits
Humidity control limited to 10…95 °C chamber temperature

Although the chamber operates from -70 to 180 °C, humidity control is only permitted between 10 and 95 °C. Outside this range, humidity must be switched off to avoid condensation and sensor damage.

Operating Manual MKF/MKFT (E5) 10/2026, Section: Technical data
Process Limits
Maximum heat compensation load is 400 W

The chamber can compensate a maximum heat load of 400 W from the test specimen. Exceeding this may prevent the chamber from reaching or holding setpoints, especially at low temperatures, and can lead to extended recovery times.

Data Sheet Model MKFT 240 en.pdf; Technical data
Maintenance
Annual maintenance and leak test required

Schedule maintenance at least once a year, including a leak test per Regulation (EU) 517/2014. Document the leak test in the service log book. Also plan steam humidifier maintenance annually, depending on water quality and usage.

Operating Manual MKF/MKFT (E5) 10/2026, Section: Maintenance and service
Maintenance
Service message appears after 8760 hours or two years

After 8760 operating hours or two years, a service message is displayed. It reappears every two weeks after confirmation until reset by BINDER Service. Plan a service intervention to reset the message and perform required checks.

Operating Manual MKF/MKFT (E5) 10/2026, Section: Maintenance and service
Cooling & Media
Water quality affects humidifier maintenance interval

The steam humidifier requires maintenance at least annually, but the interval depends on water quality and the amount of steam produced. High mineral content or impurities may necessitate more frequent servicing.

Operating Manual MKF/MKFT (E5) 10/2026, Section: Maintenance and service
Control & I/O
Both main and rear power switches must be on

From size 115 on, the chamber has a rear power switch in addition to the main power switch. For commissioning and troubleshooting, ensure both switches are in the ON position; otherwise the chamber will not power up.

Operating Manual MKF/MKFT (E5) 10/2026, Section: Chamber description

Selection & Integration Q&A

When should I choose the MKFT 240 over the MKFT 115 or MKFT 720?

Choose the MKFT 240 for a 228 L interior volume, balancing the smaller MKFT 115 and larger MKFT 720. All share the -70…180 °C range, but the 240 offers 30 kg per rack and 400 W heat compensation, suitable for mid-sized test loads.

What ambient conditions and duty-cycle limits apply to the MKFT 240?

The manual specifies annual maintenance and a leak test; the chamber is not intended for continuous operation at maximum load. Ensure the ambient temperature is within the specified range and keep the condenser fan grid clean, especially in dusty environments.

What maintenance items and accessories are not included in the base delivery?

The base delivery excludes the recommended disinfectant spray (Art. No. 1002-0022), water connection kit, hose burst protection kit, and optional RS485 or analog outputs. Annual maintenance and leak test are required and not included.

Dimensional Drawings & Technical Documentation

Dimensional drawings

MKFT 240 — drawing 1

Click drawing to inspect vector dimensions

Technical documentation

PDF
Data Sheet Model MKFT 240 en
Datasheet ·852,1 КБ ·10 pp.
View PDF
PDF
MKF+MKFT (E5) 10 2026 en
Manual ·18,1 МБ ·179 pp.
View PDF