BINDER UF V 350
BINDER UF V 350 — Ultra-low temperature freezers with Temperature -90…-40 °C.
The UF V 350 is a 402 L ultra-low temperature freezer with a two-stage hydrocarbon refrigerant cascade (R290/R170) reaching -90 °C, distinguished within the UF V series by its support feet and absence of CO2 emergency cooling or door access options. It serves as a standalone -80 °C-class storage unit in laboratory cold chains, with a 210 min cooling-down time and 1.6 kW single-phase 230 V supply.
Direct drop-in replacements
BINDER UF V Series — Model Comparison & Selection
Full specifications
| Temperature | -90...-40 °C |
| Interior volume | 402 L (all variants) |
| Nominal power | 1.6 kW |
| Temperature fluctuation (-80 °C) | 4.0 K |
| Temperature uniformity (-80 °C) | 3.5 K |
| Article Number mfr | 9020 |
| Depth | 938 mm (all variants) |
| Height | 1966 mm (all variants) |
| Interior width | 706 mm (all variants) |
| Power frequency | 50 Hz |
| Rated voltage | 230 V |
| Unit fuse mfr | 10.0 A |
| Phase (Nominal voltage) mfr | 1 |
| Cool-down time | 210 min |
Description
Construction and series positioning
- The UF V 350 is the smallest chamber in the UF V (E3) series, with 402 L interior volume and 706 mm interior width; siblings UF V 500 and UF V 700 share the -90…-40 °C range but offer larger volumes and options (CO2 emergency cooling, door access system) not available on the 350.
- This model is the only UF V variant with support feet for leveling; installation also uses rear-wall spacers to maintain clearance.
- Refrigeration uses a two-stage cascade: stage 1 R290 (0.150 kg) and stage 2 R170 (0.150 kg), both flammable hydrocarbons; maximum system pressure is 28 bar.
- The RD4 controller provides set-point entry, a DIN 12880 class 3.1 temperature safety device, tolerance/alarm settings, Ethernet, USB, and an optional DL1 data recorder.
Behavior under load and in operation
- Factory temperature fluctuation at -80 °C is 4.0 K and uniformity 3.5 K; cooling-down time to setpoint is 210 min.
- The safety controller (class 3.1 per DIN 12880) monitors overtemperature independently of the main control loop; alarm states trigger the zero-voltage relay output.
- IP 20 protection per EN 60529 means the chamber must not be exposed to water or damp environments.
Installation, connection and control
- Electrical: 230 V 1~ 50 Hz, 1.6 kW nominal, 10.0 A unit fuse, CEE 7/7 plug; supply tolerance ±10%.
- The RD4 supports Ethernet (MAC/IP/subnet/gateway/DNS, automatic or manual) and USB data transfer; an optional analog output for temperature and an advanced voltage booster are available.
- Door hinges, handle and locking counterpart require annual cleaning and lubrication with medical vaseline.
Integration & Operating Notes
The chamber is rated 230 V 1~ 50 Hz with a 10.0 A unit fuse and 1.6 kW nominal power. Operation outside the ±10% voltage tolerance risks compressor and controller malfunction; where the site supply is unstable, the optional advanced voltage booster should be specified.
The UF V 350 uses support feet (unique to this model in the series) for leveling, and rear-wall spacers must be fitted to maintain the required distance from the wall. IP 20 rating prohibits installation in damp areas or where water exposure is possible.
The RD4 provides a zero-voltage relay alarm output plus Ethernet and USB interfaces. Alarm conditions (safety controller, tolerance range, door open, power failure, sensor failure) can be forwarded to external monitoring via the relay contact or network; configure tolerance range and alarm delays accordingly.
Selection & Integration Q&A
Pick the 350 for 402 L capacity where CO2 emergency cooling and the door access system are not needed — those options exist only on the 500/700. The 350 is also the only UF V model with support feet for leveling; larger siblings suit higher inventory volumes.
A 230 V 1~ 50 Hz supply within ±10%, fused at 10.0 A, with CEE 7/7 plug, sized for 1.6 kW. For remote monitoring, use the Ethernet port (configurable IP/DNS) or the volt-free alarm relay; an optional analog temperature output is available.
IP 20 per EN 60529 means no damp areas or water exposure. Fit rear-wall spacers and level via the support feet. The R290/R170 cascade is flammable, so the room needs ventilation and no ignition sources; max system pressure is 28 bar.
Annual cleaning and medical-vaseline lubrication of door handle, hinges and locking counterpart, plus annual electrical safety testing per EN 50678/50699. Storage racks and cryo boxes, DL1 data recorder, analog output and voltage booster are options not included in base delivery.