Elmo Rietschle 2BV7061
Elmo Rietschle 2BV7061 — Liquid Ring Vacuum Pumps with Motor power 2.5 kW.
The 2BV7061 is a liquid-ring vacuum pump/compressor from the L-BV7N series, built as a close-coupled pump-motor unit with a 2.5 kW IE3 motor and IP55 protection. It is the -1 variant of the 2BV7061, distinguishing it from the -2 and -3 variants of the larger 2BV7060, 2BV7070 and 2BV7071 models. It is intended for vacuum generation or low-pressure compression where a nominal operating-liquid flow of 0.23 m³/h and a priming fill of 0.55 l are required.
Elmo Rietschle L-BV7 Series — Model Comparison & Selection
Full specifications
| Max inlet pressure | 1.9 bar abs. (50 Hz) 60 Hz: 1.9 bar abs. |
| Motor power | 2.5 kW (50 Hz) |
| Weight | 30 kg |
| Weight approx. (alt var) mfr | 66 lb |
| Power supply | AC (3~ 50/60 Hz) |
| Noise level | 70 dB(A) (50 Hz) 60 Hz: 70 dB(A) |
| Operating temperature | 80 °C |
| Protection rating | IP55 |
| Ambient temperature limit | 40 °C |
Description
Construction and series positioning
- The 2BV7061 is a liquid-ring machine with an eccentrically arranged impeller in a cylindrical housing; the operating liquid forms a rotating ring that draws in, compresses and discharges gas through inlet and discharge ports.
- It is the only model in the L-BV7N series listed as variant -1; the 2BV7060, 2BV7070 and 2BV7071 are available as variants -2 and -3. This makes the 2BV7061 a distinct modification within the series, not a simple power upgrade.
- The unit is close-coupled to a 2.5 kW AC motor for 3~ 50/60 Hz supply, IP55, insulation class F. The data sheet covers cast iron (standard, RAL 9006) and stainless steel (CrNi steel casing and port plate, bronze impeller, cast iron lantern) versions, as well as IE3 and NP efficiency variants and multiple voltage ranges.
- Sibling models differ in pressure capability and power: the 2BV7060 has a lower motor power (1.60 kW) and a higher max inlet pressure (2.4 bar), while the 2BV7070/7071 have higher pumping speeds. The 2BV7061 has a lower max inlet pressure (1.9 bar abs.) than the 2BV7060 and a lower motor power (2.5 kW) than the 2BV7070/7071.
Behavior under load and in different modes
- In compressor operation at inlet pressure p1 = 1 bar abs., the maximum discharge pressure is 1.9 bar abs. at both 50 and 60 Hz. This is lower than the 2BV7060 (2.0/2.4 bar abs.) and the 2BV7070/7071 (3.0/2.5 and 3.5/2.2 bar abs.), so the 2BV7061 is suited to lower-pressure compression duties.
- In vacuum-pump operation, the maximum discharge pressure is 1.3 bar abs. The maximum temperature of pumped gases/vapors is 80 °C.
- The operating-liquid temperature range is +5 °C to +80 °C, with a nominal +15 °C. The minimum inlet pressure depends on operating-liquid temperature (Fig. 1 in the manual).
- Nominal operating-liquid flow rate with dry air extraction and water at 15 °C is 0.23 m³/h. The priming filling amount is 0.55 l.
- Two operating modes are defined: self-priming operation and operation with operating-liquid feed (manual or automatic). The mode determines filling and commissioning procedure.
Installation, connection and operation
- The unit must be installed on a surface that limits total vibration velocity to 4.5 mm/s. Feet bolting uses 4 x M8-6.8 for the 2BV706 frame size.
- Minimum distance from fan guard to adjacent surface is 34 mm to ensure heat dissipation.
- Maximum installation height is 1000 m above sea level; higher altitudes require consultation with service.
- Ambient temperature must remain between +5 °C and +40 °C.
- Electrical connection: terminal plate tightening torques are 0.8–1.2 Nm for M4 and 1.8–2.5 Nm for M5. Clearance between bare live parts and to ground must be at least 5.5 mm at nominal voltage ≤ 690 V. Permissible supply deviations without performance reduction are ±5 % voltage and ±2 % frequency.
- Pipe connections on intake and discharge must not be tightened beyond 100 Nm.
- For self-priming operation, a vacuum of at least 900 mbar abs. must be present in the inlet pipe at switch-on, and the liquid level in the feed pipe/reservoir must be at the same level as the center of the unit shaft. During operation the liquid level in the reservoir may not drop below approximately 1 m below the center of the unit shaft.
- For operation with operating-liquid feed, set pre-pressure pA in the feed pipe approximately 1 bar above the inlet pressure pB.
Integration & Operating Notes
The maximum temperature of pumped gases/vapors is +80 °C. Higher temperatures require system measures to prevent burns, such as a separating safety device (cover). Also ensure the operating-liquid temperature remains between +5 °C and +80 °C, as the minimum inlet pressure depends on it.
The installation surface and foundation must ensure that the total vibration velocity does not exceed 4.5 mm/s. Higher vibration shortens service life and can cause mechanical damage. Use the specified 4 x M8-6.8 bolts for the 2BV706 frame size and verify vibration after installation.
A minimum distance of 34 mm must be kept between the fan guard and any adjacent surface to ensure unobstructed heat dissipation. Also respect the maximum installation height of 1000 m above sea level and ambient temperature range of +5 °C to +40 °C.
In the terminal box, maintain at least 5.5 mm clearance between bare live parts and to ground at nominal voltage ≤ 690 V. Tighten M4 terminals to 0.8–1.2 Nm and M5 terminals to 1.8–2.5 Nm. Ensure no protruding wire pieces. Supply deviations of ±5 % voltage and ±2 % frequency are permissible without performance reduction.
For self-priming operation, a vacuum of at least 900 mbar abs. must be present in the inlet pipe at switch-on, and the liquid level in the feed pipe/reservoir must be at the same level as the center of the unit shaft. During operation, the reservoir level may not drop below approximately 1 m below the shaft center. Pre-throttle on the inlet side if needed.
When operating with operating-liquid feed, set the pre-pressure pA in the feed pipe to approximately 1 bar above the inlet pressure pB. The nominal operating-liquid flow rate for the 2BV7061 is 0.23 m³/h with dry air extraction and water at 15 °C. Use 0.55 l for priming fill before commissioning.
The maximum installation height is 1000 m above sea level. Operating at higher altitudes requires consultation with the service department because motor cooling and performance may be affected. This is not a user-adjustable limit.
Selection & Integration Q&A
Choose the 2BV7061 when you need a 2.5 kW liquid-ring machine with a maximum compressor discharge pressure of 1.9 bar abs. at p1 = 1 bar abs. The 2BV7060 offers higher pressure (2.4 bar abs.) but lower motor power (1.60 kW); the 2BV7070/7071 have higher pumping speeds and higher compressor discharge pressures (3.0/2.5 and 3.5/2.2 bar abs.), but are larger and more powerful. The 2BV7061 is also the only variant -1 in the series.
For operation with operating-liquid feed, set the pre-pressure in the feed pipe to approximately 1 bar above the inlet pressure. Provide a nominal flow of 0.23 m³/h (water at 15 °C, dry air). For self-priming mode, ensure the reservoir level is at the shaft center at start and never drops more than 1 m below it during operation.
Install on a surface that limits vibration velocity to 4.5 mm/s, using 4 x M8-6.8 bolts. Keep at least 34 mm clearance from the fan guard. Ambient temperature must be +5 °C to +40 °C, and installation height must not exceed 1000 m above sea level. The pumped gas temperature must not exceed 80 °C.
The base delivery does not include operating liquid, piping, or electrical cables. The manual provides a fault table for troubleshooting. Regular checks should include operating-liquid flow and temperature, vibration levels, and terminal tightness. No specific maintenance intervals are given in the provided facts; consult the service department for altitude >1000 m or other deviations.