Elmo Rietschle 2BV7070 — Liquid Ring Vacuum Pumps with Pumping speed 500 m³/h.

The 2BV7070 is a liquid-ring vacuum pump/compressor with an eccentrically mounted impeller in a cylindrical casing, using an operating-liquid ring for gas handling. It delivers 500 m³/h at 50 Hz (575 m³/h at 60 Hz) and accepts inlet pressures up to 8 bar abs., distinguishing it from smaller siblings 2BV7060/7061. It serves as a robust vacuum source or low-pressure compressor in systems requiring moderate flow and high inlet pressure tolerance.

Pumping speed
500 m³/h

Elmo Rietschle L-BV7 Series — Model Comparison & Selection

Model Max inlet pressure, kPaMotor power, kWNoise level, dBPower supplyWeight, kgOperating principle
2BV7070 Current 8—72200 VΔ39Liquid ring
2BV7060 2001.670AC20Liquid ring
2BV7061 1.92.570AC30—
2BV7071 86.376AC68Liquid ring

Full specifications

Core Performance & Functional Specifications
Max inlet pressure 8 bar abs.
Operating principle Liquid ring
Pumping speed 500 m³/h (50 Hz)
60 Hz: 575 m³/h
Suction capacity (alt 60 Hz) mfr 660-725 m3/h (60 Hz)
Max. discharge pressure during vacuum-pump operation (alt var) mfr 1.3 bar abs.
Dimensions, Weight & Mechanical Design
Weight 39 kg (2BV7070-2)
2BV7070-3: 53 kg
Electrical, Power & Drive Specifications
Power supply 200 VΔ
Voltage (alt var) mfr 550-600 VΔ
Operating Conditions, Environment & Protection
Noise level 72 dB(A) (50 Hz)
Operating temperature +80 °C
Ambient temperature limit +40 °C

Description

Construction and series positioning

Behavior under load and media

Installation, connection and operation

Integration & Operating Notes

Process Limits
Discharge pressure must not exceed 1.3 bar abs. in vacuum duty

In vacuum-pump operation, the system back-pressure on the discharge side must remain below 1.3 bar abs. Exceeding this limit can overload the pump and damage the liquid-ring mechanism. When pumped gases are passed on, the limit is further reduced to 1.1 bar abs. Ensure downstream components and piping do not create excessive restriction.

Operating Instructions, Chapter 4.3, p. 10 and Chapter 8.1, p. 22
Process Media
Operating-liquid flow must be set to 0.28 m³/h at 50 Hz

For dry air extraction with water at 15 °C, the nominal operating-liquid flow rate is 0.28 m³/h at 50 Hz (0.34 m³/h at 60 Hz). The operating-liquid temperature must stay between +5 and +80 °C, with +15 °C nominal. Deviating from these conditions affects minimum inlet pressure and pump performance; adjust the feed system accordingly.

Operating Instructions, Chapter 4.3, p. 11
Control & I/O
Self-priming start requires ≥900 mbar abs. in inlet pipe

In self-priming mode, before switch-on the inlet pipe must be evacuated to at least 900 mbar abs. and the liquid level in the feed pipe or reservoir must be at the same level as the center of the unit shaft. During operation, the reservoir level must not drop more than 1 m below the shaft center. These conditions must be verified by the control sequence to prevent dry running or cavitation.

Operating Instructions, Chapter 8.2, p. 24
Electrical
Terminal plate screws must be tightened to specified torques

Electrical connections in the terminal box require M4 screws tightened to 0.8–1.2 Nm and M5 screws to 1.8–2.5 Nm. Maintain at least 5.5 mm clearance between bare live parts and between live parts and ground. The supply must be within ±5 % voltage and ±2 % frequency of the motor rating plate to avoid performance loss or overheating.

Operating Instructions, Chapter 7.2, p. 18
Maintenance
Check operating-liquid level and quality regularly

The operating liquid must be maintained within temperature limits and free of excessive contaminants. During self-priming operation, monitor the reservoir level to ensure it does not fall below approximately 1 m under the shaft center. Refer to the fault table in Chapter 9 for troubleshooting symptoms such as reduced performance or unusual noise.

Operating Instructions, Chapter 8.2, p. 24 and Chapter 9

Selection & Integration Q&A

When should I choose the 2BV7070 instead of the 2BV7060 or 2BV7071?

Choose 2BV7070 for 500 m³/h at 50 Hz and inlet pressures up to 8 bar abs. The 2BV7060/7061 are limited to ~2 bar abs. and lower flow; the 2BV7071 offers same pressure but higher power (6.3 kW) and flow. Select 2BV7070 for mid-range high-pressure vacuum duty.

What are the requirements for the operating-liquid supply system?

Provide operating liquid at 0.28 m³/h (50 Hz) with temperature +5 to +80 °C (nominal +15 °C). For feed mode, set pre-pressure pA about 1 bar above inlet pressure pB. Ensure piping can withstand 100 Nm tightening torque and maintain discharge pressure below 1.3 bar abs. in vacuum duty.

What maintenance items and accessories are not included in the base delivery?

The base unit does not include operating liquid, piping, valves, or control devices for feed systems. Self-priming operation requires an external reservoir and inlet piping capable of 900 mbar abs. vacuum. Electrical cables and terminal lugs are not supplied; use M4/M5 terminals torqued to 0.8–1.2/1.8–2.5 Nm.

Dimensional Drawings & Technical Documentation

Technical documentation

PDF
Technical Data Sheet — L-BV7 2BV7070 IE3 compressor (EN)
Datasheet ·266,7 КБ ·3 pp.
View PDF
PDF
Operating Instructions — (EN)
Manual ·3,5 МБ ·44 pp.
View PDF